BrandMETTLER TOLEDO
OriginSwitzerland
ModelUV5Bio / UV5Nano
Optical DesignDual-wavelength
DetectorCCD array
Wavelength Range190–1100 nm
Wavelength Accuracy±1.0 nm
Stray Light (at 198 nm, KCl)>2.0 A
Scan Time (full spectrum)1 s
AutomationAutomatic wavelength selection, integrated cuvette changer, FillPalMini peristaltic pump
ComplianceASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 ready (via LabX®)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelUV5, UV7
Optical DesignSingle-beam with pulsed xenon lamp
Detector2048-pixel CCD array
Wavelength Range190–1100 nm
Wavelength Accuracy±1.0 nm (UV5), ±0.8 nm (UV7)
Stray Light<0.01% T at 198 nm (KCl)
Scan SpeedFull spectrum in ≤1 s
Photometric Accuracy±0.01 A (K₂Cr₂O₇)
Wavelength Resolution (toluene in n-hexane)>1.5 nm (UV5), >1.9 nm (UV7)
Display7″ QVGA color TFT touchscreen (400 × 800 px)
Dimensions (L×W×H, without controller)208 × 255 × 228 mm
Weight (with controller)6.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMD200
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPoolDirect
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelMD100
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiperScan
OriginGermany
ModelFinder SD
Spectral Range1000–1900 nm
Spectral Resolution10 nm
Stray Light≤0.20%
Measurement Time<5 s (average of ≥500 scans), configurable from 1–15 s
DetectorSingle-element uncooled InGaAs
Wavelength Accuracy±0.5 nm
Wavelength Repeatability±0.2 nm
Photometric Reproducibility±0.1%
SNR>2000:1 (≥2000 scans), >1000:1 (≥500 scans)
Photometric Linearity (max/RMS)≤1% / <1%
Light SourceTungsten-halogen lamp
Sampling InterfaceDiffuse reflectance probe (23 mm aperture)
Thermal StabilityYes
Dimensions (W×D×H)225 × 235 × 385 mm
Weight9 kg
InterfaceUSB Type-B (with optional auxiliary I/O for motor control or sensor input)
Operating Temperature15–35 °C (Type 55) or 5–30 °C (Type 50)
Storage Temperature−20 to +60 °C (non-condensing)
IP RatingIP65
Power Supply100–240 VAC ±10%, 50–60 Hz
Power Consumption78 W (warm-up), 36 W (operation), 5 W (standby)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelEasy UV
PriceUpon Request
Wavelength Range190–1000 nm
Photometric Accuracy (K₂Cr₂O₇)±0.005 A
Wavelength Accuracy±1.5 nm
Stray Light (KCl, 198 nm)≤2.5%
Light SourceXenon Flash Lamp
Optical Path Lengths10 mm, 16 mm, 20 mm, 30 mm, 40 mm, 50 mm (1 inch equivalent)
Display4.3-inch capacitive touchscreen
Dimensions (H×W×D)176 × 201 × 362 mm
Weight4.25 kg
Max. Stored Methods80
User-Defined Quick Keys10
Supported LanguagesEnglish, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian
Colorimetric StandardsCIELAB, APHA, Gardner (30 pre-programmed color scales)
ComplianceDesigned to support pharmacopeial workflows (USP <85>, EP 2.2.25, JP 2.04)
ConnectivityUSB port for printer (USB-P25), barcode scanner (SQKitReader™), and peripheral storage
Sample HandlingFixed cuvette holder (no autosampler or cuvette changer)
Application ScopeQuantitative analysis, spectral scanning, water quality testing (Spectroquant® integration), color measurement
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeDistributor
Origin CategoryImported
ModelPoolDirect 9-in-1
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHiperscan
OriginGermany
ModelApo-Ident
Wavelength Range1000–1900 nm
Wavelength Resolution10 nm
Wavelength Stability±1 nm
Measurement Time<15 s
Operating Temperature15–35 °C
Dimensions203 × 279 × 219 mm
Weight5.2 kg
Power Supply230 V~, 50/60 Hz, 60 W
InterfaceUSB Type-B
SoftwareQuickStep Apo-Ident
OS CompatibilityWindows Vista/7/8/10 (excluding Starter editions), Linux, macOS
Minimum System Requirements1 GB RAM, Pentium 1.6 GHz CPU, 0.5 GB disk space
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeDistributor
Origin CategoryImported
ModelCheckitDirect
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMaxiDirect
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelEasy VIS
Wavelength Range330–1000 nm
Photometric Accuracy (K₂Cr₂O₇)±0.005 A
Wavelength Accuracy±1.5 nm
Light SourceTungsten Halogen Lamp
Optical Path Options10, 16, 20, 30, 40, 50 mm (1 inch)
Display4.3-inch capacitive touchscreen
Dimensions (H × W × D)176 × 201 × 362 mm
Weight4.25 kg
User-Defined MethodsUp to 80
Quick Access Keys per User10
Supported LanguagesEnglish, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian
Barcode Reader CompatibilitySQKitReader™ handheld scanner (optional)
Printer InterfaceUSB-P25
USB Host PortYes
Cuvette ChangerNot integrated
Pharmacopeia ComplianceNot specified
Colorimetric Standards25 pre-programmed methods (CIELAB, APHA, Gardner, etc.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ModelZEEnit 650P
Instrument TypeGraphite Furnace AAS
Background CorrectionDual-mode Zeeman (2-field / 3-field / dynamic field) + D₂ lamp
Furnace DesignTransversely Heated Graphite Atomizer (THGA)
Automation LevelFully Automated with Integrated Autosampler, 8-Lamp Turret, RFID-enabled Lamp Recognition
Sample IntroductionLiquid & Solid (Direct Solid Sampling compatible)
Compliance FrameworkDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ModelRXN
Instrument TypeIn-line Raman Spectrometer
Probe CompatibilityPhAT and non-PhAT probes
Sample Phase SupportSolid and liquid (dual-channel configuration)
Optical Spot Size Range1 µm to 6 mm
Application EnvironmentCertified for hazardous / classified areas (ATEX/IECEx compliant)
Spectral ResolutionHigh (typical < 4 cm⁻¹ FWHM)
ArchitectureModular, rack-mountable industrial platform
Software ComplianceSupports 21 CFR Part 11 audit trail, electronic signatures, and GLP/GMP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ModelnovAA 800F
Atomization TypeFlame
DetectorSiOSens solid-state semiconductor detector
Lamp HolderIntegrated 8-position auto-rotating turret with coded lamp recognition
Background CorrectionDeuterium arc lamp
Optical SystemSwitchable single-beam / double-beam / emission modes
Automation LevelFully automated dual atomizer switching (flame/graphite/hydride), auto-optimization, programmable dilution & autosampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Instrument TypeDouble-Beam
ModelSPECORD 200 PLUS
Optical DesignHolographic Grating Monochromator
DetectorDual-Thermostatted Photodiode Array
Wavelength Range190–1100 nm
Spectral Resolution≤1.2 nm (FWHM)
Photometric Accuracy±0.002 A (at 0.5 A, 1.0 A)
Stray Light<0.0005% T at 220 nm
Beam GeometryTrue Simultaneous Double-Beam
Wavelength CalibrationPre-aligned Holmium Oxide Filter
ComplianceUSP <857>, Ph. Eur. 2.2.25, FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, User Access Control)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ModelZEEnit 700Q
Instrument TypeFlame and Graphite Furnace AAS
Background CorrectionZeeman-effect with tunable magnetic field (2-field / 3-field / dynamic mode) + D₂ lamp
Automation LevelFully automated flame and GF-AAS operation
Sample IntroductionAuto-sampler with intelligent dilution, 8-position encoded lamp turret with RFID support
Solid Sampling OptionOptional direct solid analysis module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ModelcontrAA 800
Instrument TypeFlame and Graphite Furnace AAS
Wavelength Range185–900 nm
Light SourceHigh-Intensity Short-Arc Xenon Lamp
Detection PrincipleHigh-Resolution Continuum Source AAS (HR-CS AAS)
DetectorCCD Array
Background CorrectionAutomatic Background Correction (ABC) and Concurrent Spectrum Interference Correction (CSI)
Detection LimitSub-ppb for most elements
Elemental CoverageSimultaneous multi-element analysis across full UV-VIS-NIR range
Atomization ModesIntegrated flame and electrothermal (graphite furnace) atomization
Show next