| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-150 |
| Temperature Range (MX) | Ambient +10°C to 135°C |
| Temperature Range (SD/AP) | Ambient +10°C to 150°C |
| Temperature Stability (MX) | ±0.07°C |
| Temperature Stability (SD) | ±0.04°C |
| Temperature Stability (AP) | ±0.01°C |
| Controller Options | MX (basic digital), SD (dual-speed pump, PC-controllable via Rheocalc), AP (touchscreen, programmable, multi-language UI, variable-speed pump) |
| Pump Type | Single-speed (MX), Dual-speed (SD), Variable-speed (AP) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-250 |
| Temperature Range | –20 °C to +150 °C (depending on controller variant) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Controller Options | AP (touchscreen, programmable, multi-language), SD (dual-speed pump, Rheocalc-compatible), MX (basic digital display, single-speed pump) |
| Pump Type | Variable-speed (AP), dual-speed (SD), fixed-speed (MX) |
| Software Integration | Compatible with Brookfield Rheocalc v3.0+ for remote programming and data logging |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-550 |
| Temperature Range (MX) | –20 °C to +135 °C |
| Temperature Range (AP) | –20 °C to +200 °C |
| Temperature Range (SD) | –20 °C to +170 °C |
| Temperature Stability (MX) | ±0.07 °C |
| Temperature Stability (AP) | ±0.01 °C |
| Temperature Stability (SD) | ±0.04 °C |
| Control Interface | MX — large-character LCD |
| Pump Configuration | MX — single-speed pump |
| External Circulation | Yes |
| Max Internal Bath Volume Capacity | 600 mL (standard beaker compatibility) |
| Software Integration | Compatible with RheocalcT v3.0+ for remote parameter setting, real-time monitoring, and GLP-compliant data logging |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-650 |
| Temperature Range | –20 °C to +200 °C (depending on controller variant) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Bath Capacity | 7 L |
| Max Vessel Size | 600 mL beaker compatible |
| Control Type | Microprocessor-based SD, AP, or MX digital controller |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE, UL-listed components |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | PSL-1810 |
| Temperature Range | −80 °C to 0 °C |
| Temperature Stability | ±1 °C |
| Stirring Speed | 100–800 rpm |
| Heating Power | 450 W |
| Cooling System | Dual-compressor, air-cooled |
| Refrigerants | R507A (primary stage), R23 (secondary stage) |
| Bath Capacity | 3.5 L |
| Bath Chamber Dimensions | Φ180 × 140 H mm (SUS304 stainless steel) |
| Max. Vessel Size | Φ95 mm × 300 mL |
| External Dimensions | 530 W × 450 D × 520 H mm |
| Weight | ~70 kg |
| Control Method | PID temperature control |
| Display & Setting | Digital LED display with manual keypad input |
| Safety Functions | Leakage current protection, overcurrent cutoff, heater over-power prevention, compressor high-pressure cutoff, relay overload protection, self-diagnostic system (heater fault, sensor failure, high/low temperature alarm), compressor time-delay startup |
| Auxiliary Function | Auto power-on/off scheduling |
| Stirrer Output | 25 W |