Empowering Scientific Discovery

Dongnan Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelTGA2
Temperature Range30 °C – 1,100 °C
Sampling Rate10 data points/second
Atmosphere ControlIntegrated Mass Flow Controller (MFC) for programmable gas switching
Buoyancy CorrectionAutomatic, model-based, no blank required
One-Click Method LaunchYes
Optional CouplingsFTIR, MS, Micro GC, GC/MS
Sensor OutputMass & Temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC 3 Excellence Series
Temperature Range−150 °C to 700 °C
Data Acquisition RateUp to 50 data points per second
Sensor TypeMultiSTARe™ DSC sensor with 56 or 120 thermocouple pairs (Au/Au-Pd)
Cooling Rate0.02 K/min to 50 K/min
CalibrationFlexCal® (fully automated, multi-point, reference-based)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelMP70 / MP90
Temperature RangeRT to 350 °C
Heating Rate0.1–20 °C/min
Sample CapacityUp to 6 capillaries per run
ComplianceUSP <741>, Ph. Eur. 2.2.14, JP 17, ISO 11357-3, ASTM D1519
SafetyIntegrated optical monitoring with simultaneous transmittance measurement and reflected-light imaging
User InterfaceOne Click® color touchscreen with pre-stored method recall
Qualification SupportFactory-supplied IQ/OQ documentation and on-site qualification services available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelMP55/80
Temperature RangeAmbient to 350 °C
Heating Rate4 °C/min (programmable)
Sample Capacity6 positions
Measurement ModesMelting Point (MP), Melting Range (MR), Sliding Melting Point (SMP), Boiling Point (BP), Cloud Point (CP)
Video Recording Duration60 minutes
Maximum Results Storage50 entries
ComplianceUSP <741>, Ph. Eur. 2.2.14, JP 17, ASTM D1565, ISO 4625
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStanford
OriginUSA
ModelMPA100
Temperature Range+10 °C to 400 °C
Heating Rate0.1–20 °C/min
Temperature Repeatability±0.1 °C
Temperature Accuracy±0.3 °C (@ ~100 °C), ±0.5 °C (@ ~250 °C), ±0.8 °C (@ ~400 °C)
Capillary Outer Diameter1.4–2.0 mm
Temperature Resolution0.1 °C
Power SupplyAC 90–264 V
Weight4.1 kg
Operating Ambient0–40 °C
InterfaceUSB, RS-232
SoftwareMeltView (Windows-compatible)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0