Empowering Scientific Discovery

Dongnan Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelKB Series
Temperature Range0 °C to +70 °C
Temperature Uniformity at 37 °C±0.2 K
Temperature Fluctuation at 37 °C±0.1 K (KB 130 and larger)
Recovery Time after 30-sec Door Opening at 37 °C3 min
Internal Volume63 L to 1070 L
Power Consumption0.9 kW to 1.5 kW
RefrigerantR-600a
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelKT53 / KT115 / KT170
Temperature Range4 °C to 100 °C
Internal Volume53 L / 102 L / 163 L
External Dimensions (W×H×D, mm)660×635×630 / 860×715×655 / 860×1025×655
Internal Dimensions (W×H×D, mm)400×400×334 / 600×455×355 / 600×765×355
Net Weight63 kg / 83 kg / 102 kg
Inner DoorTempered Safety Glass (ESG)
InteriorStainless Steel Construction
Shelving2 Removable Stainless Steel Trays
Stacking CapabilityUp to KT115 Units
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBF56 / BF115 / BF260 / BF720
External Dimensions (W×H×D, mm)560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870
Internal Dimensions (W×H×D, mm)400×440×340 / 550×550×380 / 650×780×510 / 1000×1300×560
Internal Volume (L)59 / 114 / 257 / 734
Net Weight (kg)39 / 54 / 85 / 165
Max. Total Load (kg)70 / 150 / 270 / 120
Max. Load per Shelf (kg)30 / 30 / 40 / 40
Temp. RangeAmbient +8 °C to 100 °C (BF56–BF260)
Temp. Uniformity (±K @37°C)0.2 / 0.3 / 0.2 / 0.3
Temp. Fluctuation (±K @37°C)0.1 across all models
Time to Reach 37°C (min)6 / 8 / 7 / 15
Recovery Time after 30s Door Opening (min @37°C)3 / 3 / 3 / 4
Rated Power (230 V, kW)0.4 / 0.4 / 0.9 / 1.75
Standard/Max. Shelves2/4 / 2/5 / 2/8 / 2/16
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelCB Series
SterilizationDry-heat sterilization (180 °C, 2–4 h)
CO₂ Control Range0–20 % (±0.1 % typical accuracy)
Temperature RangeAmbient +5 °C to 50 °C (±0.1 °C stability at 37 °C)
Humidity ControlActive humidification with integrated water pan and saturation monitoring
Chamber Volume Options53 L to 216 L
ConstructionStainless steel interior (AISI 304), double-wall insulated chamber, HEPA-filtered air circulation (ISO Class 5 compliant)
ComplianceIEC 61010-1, EN 61326-1, CE marked for in vitro diagnostic use (IVDR Annex II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelKBF-S ECO Solid.Line
Temperature Range (with Humidification)0 °C to +70 °C
Humidity Range10 % to 98 % RH
Temperature Uniformity (25 °C / 60 % RH)±0.1 K
Temperature Fluctuation (40 °C / 75 % RH)±0.1 K
Humidity Fluctuation (40 °C / 75 % RH)±0.3 % RH
Recovery Time after 30-sec Door Opening (40 °C / 75 % RH)11–17 min
Internal Volume Options247 L, 400 L, 700 L, 1020 L
Power Consumption (25 °C / 60 % RH)55–90 Wh/h
Noise Level45–49 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBF
Internal Volume400 L
External Dimensions (W×H×D)1235 × 1025 × 765 mm
Internal Dimensions (W×H×D)1000 × 800 × 500 mm
Net Weight (empty)145 kg
Max. Total Load90 kg
Max. Load per Shelf35 kg
Temperature RangeAmbient +5 °C to 100 °C
Temp. Uniformity (±K @37°C)0.4
Temp. Fluctuation (±K @37°C)0.1
Heating Time to 37°C12 min
Recovery Time (30 s door opening @37°C)5 min
Rated Power (230 V)0.85 kW
Standard Shelves2 (up to 9 optional)
Preheating Chamber TechnologyACT.line™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelCBF Series
Internal Volume170 L / 267 L
Net Weight (empty)95 kg / 125 kg
Max. Total Load30 kg / 40 kg
Max. Load per Shelf10 kg
Rear Wall Clearance100 mm
Side Wall Clearance50 mm
Internal Dimensions (W×H×D)560×600×505 mm / 620×750×575 mm
External Dimensions (W×H×D)680×870×715 mm / 740×1020×785 mm
Temp. RangeRT + 6 °C to 60 °C
Temp. Uniformity±0.4 K @ 37 °C
Temp. Stability±0.1 K @ 37 °C
Temp. Recovery Time (30 s door open)6 min @ 37 °C
Humidity Range50–95 %RH
CO₂ Range0–20 vol.%
CO₂ Sensing PrincipleSingle-beam IR
Rated Power (230 V)1.4 kW / 1.5 kW
Standard/Max. Shelves3/6 or 3/8
Sterilization180 °C dry-heat
Chamber MaterialSeamless stainless steel with shelf reinforcement system
Gas MixingVenturi-type CO₂ injection nozzle
Control InterfaceTouchscreen controller with USB data export, Ethernet, zero-voltage alarm contacts
Data LoggingInternal recorder with open-format measurement values
Safety SystemsCO₂ Fail-Safe pH monitoring, optical & acoustic fault diagnostics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelCB
Internal Volume (L)53 / 170 / 260
Net Weight (kg, empty)53 / 98 / 125
Max Total Load (kg)30 / 30 / 40
Max Load per Shelf (kg)10 / 10 / 10
Rear Wall Clearance (mm)100 / 100 / 100
Side Wall Clearance (mm)50 / 50 / 50
Internal Dimensions (W×H×D, mm)400×400×330 / 560×600×505 / 620×750×575
External Dimensions (W×H×D, mm)528×674×545 / 680×870×715 / 740×1020×785
Temp. RangeRT+4–6°C to 60°C
Temp. Uniformity (±K @37°C)0.3 / 0.3 / 0.4
Temp. Stability (±K @37°C)0.1 / 0.1 / 0.13
Humidity Range90–95% RH
CO₂ Range0–20 vol.%
CO₂ Measurement PrincipleSingle-beam IR sensor
Recovery Time after 30-sec Door Opening (min @37°C)5 / 6 / 6
Rated Power (230 V, kW)0.8 / 1.4 / 1.5
Standard/Max Shelf Quantity2/3 / 3/6 / 3/8
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBD-S 56 / BD-S 115
External Dimensions (W×H×D)560×580×515 mm / 740×790×555 mm
Internal Dimensions (W×H×D)400×400×350 mm / 550×550×390 mm
Internal Volume62 L / 118 L
Net Weight (empty)41 kg / 57 kg
Temperature RangeAmbient +5 °C to 70 °C
Temperature Uniformity (±K @ 37 °C)0.7 / 0.5
Temperature Fluctuation (±K @ 37 °C)0.1 / 0.2
Recovery Time (min @ 37 °C, 30 s door opening)15 / 15
Power Consumption (Wh/h @ 37 °C)25 / 25
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelCB-S Solid.Line
Internal Volume (L)170 / 267
Net Weight (kg, empty)96 / 122
Max. Total Load (kg)30 / 40
Max. Load per Shelf (kg)10 / 10
Rear Clearance (mm)100 / 100
Side Clearance (mm)50 / 50
Internal Dimensions – W×H×D (mm)560×600×505 / 620×750×575
External Dimensions – W×H×D (mm)680×870×715 / 740×1020×785
Temp. RangeAmbient +6 °C to 50 °C
Temp. Uniformity (±K @37 °C)0.3 / 0.4
Temp. Stability (±K @37 °C)0.1 / 0.13
Recovery Time (min @37 °C, 30 s door open)6 / 8
Humidity Range90–95 % RH
CO₂ Range0–20 vol.%
CO₂ Sensing PrincipleInfrared (IR)
Rated Power (230 V)1.3 kW / 1.5 kW
Standard/Max. Shelves2 / 6 or 2 / 8
SterilizationDry-heat at 180 °C
InterfaceEthernet, USB, Dry Contact Alarm Output
Data LoggingInternal, USB exportable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
Model(s)BD115, BD240, BD400
External Dimensions (W×H×D mm)435×495×520 (BD115), 1235×1025×765 (BD400)
Internal Dimensions (W×H×D mm)222×330×277 (BD115), 1000×800×500 (BD400)
Internal Volume20 L (BD115), 400 L (BD400)
Net Weight (empty)27 kg (BD115), 135 kg (BD400)
Max. Total Load25 kg (BD115), 90 kg (BD400)
Max. Load per Shelf12 kg (BD115), 35 kg (BD400)
Temp. RangeAmbient +5 °C to 100 °C
Temp. Uniformity (±K @37°C)0.5 K
Temp. Stability (±K @37°C)0.2 K (BD115), 0.1 K (BD400)
Heating Time to 37°C59 min (BD115), 120 min (BD400)
Recovery Time after 30s Door Opening (@37°C)20 min (BD115), 10 min (BD400)
Rated Power (230 V)0.2 kW (BD115), 0.85 kW (BD400)
Standard/Max. Shelves2/4 (BD115), 2/9 (BD400)
Safety ClassTemperature Safety Device Class 3.1 (DIN 12880), Optical Alarm
ControllerTime-Programmable, RS 422 Interface
ConstructionESG (Tempered Safety Glass) Inner Door, Adjustable Exhaust Valve, Apt.line™ Preheating Chamber Technology, Natural Convection Design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelKB ECO 240 / KB ECO 400 / KB ECO 720 / KB ECO 1020
Temperature Range0–70 °C (up to 28 K below ambient)
Temp. Uniformity at 37 °C±0.1 K
Temp. Stability at 37 °C±0.1 K
Max. Heat Compensation at 40 °C350–500 W
Recovery Time (30 s door open, 37 °C)3–6 min
Rated Power1.2 kW
Internal Volume247–1020 L
Net Weight152–327 kg
Max. Load per Shelf30–45 kg
Max. Total Load100–150 kg
Wall Clearance (rear/side)100 mm
External Dimensions (W×H×D)925×1461×796 mm to 1250×1925×1149 mm
Internal Dimensions (W×H×D)650×785×485 mm to 973×1250×836 mm
Shelf Capacity (standard/max)2/9 to 2/15
Sound Pressure Level43–47 dB(A)
Energy Consumption at 37 °C65–105 Wh/h
InterfaceEthernet, USB
DisplayLCD with alarm and data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBD 56 / BD 115 / BD 260 / BD 720
External Dimensions (W×H×D, mm)560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870
Internal Dimensions (W×H×D, mm)360×420×380 / 510×530×420 / 610×760×545 / 960×1280×600
Internal Volume (L)57 / 112 / 253 / 737
Net Weight (kg)39 / 54 / 85 / 170
Max. Total Load (kg)70 / 150 / 270 / —
Max. Load per Shelf (kg)30 / 30 / 40 / 40
Temp. RangeAmbient +5 °C to 100 °C
Temp. Uniformity (±K @37°C)0.3 / 0.3 / 0.3 / 0.7
Temp. Fluctuation (±K @37°C)0.1 / 0.1 / 0.2 / 0.1
Heating Time to 37°C (min)42 / 55 / 60 / 70
Recovery Time after 30s Door Opening (min @37°C)15 / 15 / 16 / 23
Rated Power (230 V, kW)0.3 / 0.35 / 0.85 / 1.65
Standard/Max. Shelving2/4 / 2/5 / 2/8 / 2/16
Safety ClassIndependent Temperature Safety Device Class 3.1 (DIN 12880) with Optical Alarm
Interior DoorTempered Safety Glass (ESG)
Control InterfaceLCD Display with APT.line™ Technology
VentilationMechanical Exhaust Valve
Data LoggingUSB Interface for Recording
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0