BrandBINDER
OriginGermany
ModelBF56 / BF115 / BF260 / BF720
External Dimensions (W×H×D, mm)560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870
Internal Dimensions (W×H×D, mm)400×440×340 / 550×550×380 / 650×780×510 / 1000×1300×560
Internal Volume (L)59 / 114 / 257 / 734
Net Weight (kg)39 / 54 / 85 / 165
Max. Total Load (kg)70 / 150 / 270 / 120
Max. Load per Shelf (kg)30 / 30 / 40 / 40
Temp. RangeAmbient +8 °C to 100 °C (BF56–BF260)
Temp. Uniformity (±K @37°C)0.2 / 0.3 / 0.2 / 0.3
Temp. Fluctuation (±K @37°C)0.1 across all models
Time to Reach 37°C (min)6 / 8 / 7 / 15
Recovery Time after 30s Door Opening (min @37°C)3 / 3 / 3 / 4
Rated Power (230 V, kW)0.4 / 0.4 / 0.9 / 1.75
Standard/Max. Shelves2/4 / 2/5 / 2/8 / 2/16
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBD-S 56 / BD-S 115
External Dimensions (W×H×D)560×580×515 mm / 740×790×555 mm
Internal Dimensions (W×H×D)400×400×350 mm / 550×550×390 mm
Internal Volume62 L / 118 L
Net Weight (empty)41 kg / 57 kg
Temperature RangeAmbient +5 °C to 70 °C
Temperature Uniformity (±K @ 37 °C)0.7 / 0.5
Temperature Fluctuation (±K @ 37 °C)0.1 / 0.2
Recovery Time (min @ 37 °C, 30 s door opening)15 / 15
Power Consumption (Wh/h @ 37 °C)25 / 25
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBD 56 / BD 115 / BD 260 / BD 720
External Dimensions (W×H×D, mm)560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870
Internal Dimensions (W×H×D, mm)360×420×380 / 510×530×420 / 610×760×545 / 960×1280×600
Internal Volume (L)57 / 112 / 253 / 737
Net Weight (kg)39 / 54 / 85 / 170
Max. Total Load (kg)70 / 150 / 270 / —
Max. Load per Shelf (kg)30 / 30 / 40 / 40
Temp. RangeAmbient +5 °C to 100 °C
Temp. Uniformity (±K @37°C)0.3 / 0.3 / 0.3 / 0.7
Temp. Fluctuation (±K @37°C)0.1 / 0.1 / 0.2 / 0.1
Heating Time to 37°C (min)42 / 55 / 60 / 70
Recovery Time after 30s Door Opening (min @37°C)15 / 15 / 16 / 23
Rated Power (230 V, kW)0.3 / 0.35 / 0.85 / 1.65
Standard/Max. Shelving2/4 / 2/5 / 2/8 / 2/16
Safety ClassIndependent Temperature Safety Device Class 3.1 (DIN 12880) with Optical Alarm
Interior DoorTempered Safety Glass (ESG)
Control InterfaceLCD Display with APT.line™ Technology
VentilationMechanical Exhaust Valve
Data LoggingUSB Interface for Recording