- All
- Favorite
- Popular
- Most rated
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP-2000+ |
| Temperature Range (L-Series) | 5–75°C |
| Temperature Range (H-Series) | 50–235°C |
| Shear Rate Range | 10–13,300 s⁻¹ |
| Sample Volume | 24–1700 µL (depending on cone geometry) |
| Cone Angles | 1°, 2°, 4° (standard), custom options available |
| Torque Range | High-torque mode up to 2000+ dyne·cm |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Control Interface | Built-in touchscreen + PC via CAPCALC™ software |
| Cone/Plate Gap Adjustment | Motorized auto-gap calibration |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PFT |
| Pricing | Available Upon Request |
| Axial Load Capacity | 7 kg |
| Load Accuracy | ±0.6% FSR |
| Plunger Speed | 0.1–5 mm/s |
| Displacement Accuracy | ±0.3 mm |
| Torque Range | ±7.0 N·m |
| Torque Accuracy | ±1.2% FSR |
| Hopper Rotation Speed | 1–5 RPH |
| Temperature Sensing Range | −20 °C to 120 °C |
| Humidity Sensing Range | 10–95% RH (±5% accuracy) |
| Test Modes | Flow Function, Time-Consolidated Flow Function, Wall Friction, Bulk Density |
| Flow Function Submodes | Demo (8 min), Standard (38 min), User-Defined Time Consolidation |
| Shear Algorithm Outputs | Peak Shear Stress, Steady-State Yield Locus, Stick-Slip Identification |
| Output Parameters | Flow Function Index (FF), Arching Diameter (Index), Rathole Diameter, Hopper Half-Angle, Gravity Chute Angle (Wall Friction Angle), Bulk Density Curve |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVPlus |
| Display | 5-inch full-color touchscreen |
| Speed Control | 740 programmable RPM increments (0.1–200 rpm) |
| Viscosity Range | 1 cP to 320,000,000 cP (depending on spindle and speed selection) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Torque Measurement | 0.1–100% of full-scale torque (mN·m, dyne·cm, %) |
| Temperature Compensation | ±5°C |
| Interface | USB + Bluetooth (DVPlus CONNECT compatible) |
| Optional Accessory | RTD temperature probe (DVP-94Y) |
| Language Support | English, French, German, Portuguese, Spanish, Japanese, Chinese |
| Compliance | Designed for GLP/GMP environments |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T Gel Time Tester |
| Type | Rotational Viscometer with Gel Time Measurement Capability |
| Compliance | ASTM D2471, ISO 3219, USP <911> (Gelation Time) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–6,000,000 cP (mPa·s) |
| Temperature Accuracy | ±1.0% of full-scale reading |
| Speed Control | 200 programmable RPM settings (0.1–200 rpm) |
| Display | 5-inch full-color touchscreen |
| Compliance | ASTM D2196, ISO 2555, USP <911>, GLP/GMP-ready data logging |
| Interface | USB PC connectivity with optional PG Flash and Rheocalc T software support |
| Standard Spindles | LV (4), RV/HA/HB (6) depending on configuration |
| Operating Environment | Ambient temperature |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSX-CC |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Model | KU-3 |
| Measurement Principle | ASTM D562-compliant Krebs Unit (KU) viscosity measurement via rotational drag on standardized paddle-type spindle |
| Standard Spindle | KU-1030 |
| Sample Vessel Compatibility | 1-pint (473 mL) and ½-pint (237 mL) cans (ASTM D562 compliant) |
| Optional | Quart (946 mL) can fixture |
| Measurement Range | 40–141 KU |
| Equivalent Units | 32–1099 g (load), 27–5274 mPa·s (cP) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.5% |
| Display | LED with selectable units (KU, g, cP) |
| Hold Function | Yes |
| Interface | Magnetic spindle coupling |
| Compliance | ASTM D562, ISO 2555 (indirectly applicable), GLP-ready operation |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | LVT/RVT/HAT/HBT |
| Instrument Type | Analog Dial-Reading Rotational Viscometer |
| Mounting Style | Benchtop Fixed Configuration |
| Operating Environment | Ambient Temperature (15–30°C) |
| Viscosity Range (cP) | LVT: 1–2M |
| RVT | 100–10M |
| HAT | 200–16M |
| HBT | 800–64M |
| Minimum Measurable Viscosity | 0.3 cP (LVT, with UL adapter) |
| Speed Range | 0.3–100 RPM (6–10 programmable speeds depending on model) |
| Spindle Count | 4 (LVT), 6 (RVT/HAT), 6 (HBT) |
| Accuracy | ±1% of full-scale reading |
| Repeatability | ±0.2% of reading |
| Compliance | Designed for ASTM D2196, ISO 2555, ISO 3219, and USP <911> viscosity testing protocols |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNXLVCP |
| Viscosity Range (mPa·s) | 0.1–3,000 |
| Shear Rate Range | 7.5–92,000 s⁻¹ (depending on cone geometry) |
| Sample Volume | 0.5–2.0 mL |
| Speed Range | 0.01–250 rpm (2600 discrete steps) |
| Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Cone/Plate Gap Adjustment | Motorized touchscreen-controlled |
| Display | 7-inch full-color capacitive touch screen |
| Compliance | FDA 21 CFR Part 11, GAMP 5-ready (configurable at order), GLP/GMP-supportive audit trail |
| Data Storage | 150 MB internal memory |
| Interface | USB host/device, RS-232 (optional) |
| Temperature Control | Integrated Peltier interface for external bath (AP/SD series) or high-temp systems |
| Mathematical Models | Casson, Bingham Plastic, Power Law, Thixotropy Index (TI), Yield Stress estimation |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Viscosity Range (LV) | 0.01–250 cP (mPa·s) |
| Viscosity Range (RV/HA/HB with Optional Spindles) | up to 320M cP |
| Speed Control | 2600 programmable RPM increments (0.01–250 RPM) |
| Display | 7-inch full-color touchscreen |
| Temperature Accuracy | ±1% of full scale (with PT-100 probe) |
| Data Storage | 150 MB internal |
| Compliance | 21 CFR Part 11, GAMP 5 |
| Connectivity | USB, optional LIMS integration |
| Accessories Supported | UL Adapter (1 cP min), Cone & Plate systems, AP/SD temperature baths, RheocalcT software, barcode scanner, gel timer module, DIN adapters, T-spindles, spiral adaptors, small sample adapters |
| Brand | Formulaction (Microtrac Group) |
|---|---|
| Origin | France |
| Model | RHEOLASER MASTER |
| Light Source | 650 nm laser |
| Detection Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Detection Mode | Backscattered light |
| Detector | Dedicated CCD camera |
| Sample Cell | 20 mL standard glass vial (optional 4 mL) |
| Sample Capacity | 6-position automated sample tray |
| Temperature Control Range | +5 °C to 90 °C above ambient (optional up to 150 °C) |
| Temperature Stability | ±0.1 °C |
| Frequency Range (Viscoelastic Spectrum) | 10⁻⁴ Hz to 50 Hz (sample-dependent) |
| Measured Particle RMS Displacement Range | 0.1 nm – 100 nm |
| Compliance | Designed for GLP/GMP environments |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Paddle-Type |
| Pricing | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPQA |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSO |
| Price | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | RSX |
| Type | Advanced Controlled-Stress/Controlled-Rate Cone-Plate Rheometer |
| Sample Volume | As low as 0.1 mL (depending on cone geometry) |
| Shear Rate Range | 0.001–6,000 s⁻¹ |
| Shear Stress Range | 0.0038–204 kPa |
| Torque Range | 0.01–100 mN·m |
| Temperature Control Options | Peltier (±0.1 °C) or Circulating Water Bath |
| Compliance | ASTM D2196, ISO 3219, ISO 6721-10, USP <911>, FDA 21 CFR Part 11 ready (with optional software module) |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | FLUIDICAM |
| Viscosity Range | 0.1–200,000 cP |
| Shear Rate Range | 100–1.8×10⁵ s⁻¹ |
| Temperature Control Range | 4–80 °C |
| Compliance | Designed for GLP/GMP-relevant workflows with audit-trail-capable software logging |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2Plus |
| Viscosity Range (cP) | LV: 1–6M |
| RV | 100–40M |
| HA | 200–80M |
| HB | 800–320M |
| Speed Range | 0.1–200 rpm (740 programmable steps) |
| Accuracy | ±1.0% |
| Repeatability | ±0.2% |
| Display | 7″ color PCAP touchscreen (800 × 480 resolution) |
| Compliance | Optional 21 CFR Part 11 via DV360™ software |
| Connectivity | Bluetooth, USB-A, USB-B |
| Included Spindles | 4× LV, 6× RV/HA/HB (model-dependent) |
| Built-in Features | Gel time measurement, oscillatory test mode, digital leveling, viscosity test wizard, step-programmable method execution |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Helipath Elevator Stand (HPQA) |
| Pricing | Upon Request |
Show next