- All
- Favorite
- Popular
- Most rated
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | LH15/12–LF120/14 |
| Max. Temperature | 1200–1400 °C |
| Chamber Dimensions (W×D×H) | 250×250×250 mm to 500×500×500 mm |
| Chamber Volume | 15–216 L |
| External Dimensions (W×D×H) | 680×860×1170 mm to 990×1280×1530 mm |
| Power Supply | 3-phase, 5.0–26.0 kW |
| Weight | 150–470 kg |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | LHT/LB |
| Max. Temperature | 1650 °C |
| Chamber Dimensions (Ø × H) | Ø185 × 185 mm (LHT 02/17 LB) / Ø260 × 260 mm (LHT 16/17 LB) |
| Chamber Volume | 2 L / 16 L |
| External Dimensions (W × D × H) | 390 × 590 × 765 mm / 650 × 1250 × 1980 mm |
| Power Supply | 3.4 kW (1-phase) / 12.0 kW (3-phase) |
| Weight | 50 kg / 410 kg |
| Heating Element | Molybdenum Disilicide (MoSi₂) |
| Temperature Uniformity | ≤ ±5 °C (at 1600 °C, steady state) |
| Control System | SCR-controlled S-type thermocouple with overtemperature protection per EN 60519-2 Class 2 |
| Optional | Protective Gas Inlet, Manual/Automatic Gas Supply, Adjustable Bottom Air Intake, Stackable Crucible Supports, Controltherm MV Process Software |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | R Series |
| Max Operating Temperature | 1200 °C or 1300 °C |
| Tube ID | 50–120 mm |
| Heating Zone Length | 250–1000 mm |
| External Dimensions (W×D×H) | up to 1300 mm × 1170 mm × 460 mm |
| Power Supply | 1-phase (1.6–2.3 kW) or 3-phase (6.5–11.5 kW) |
| Weight | 22–89 kg |
| Control System | HiProSystem (3-zone for models ≥750 mm heating length, 1300 °C), integrated S-type thermocouple, overtemperature protection per EN 60519-2 Class 2 |
| Atmosphere Options | inert gas, vacuum-compatible configurations available |
| Software Integration | Controltherm MV for process monitoring, logging, and compliance-ready data management |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | RT |
| Max. Operating Temperature | 1100 °C / 1300 °C / 1500 °C |
| Tube Diameter (Ø) | 50–150 mm |
| Heating Zone Length | 250–360 mm |
| Uniformity (ΔT @ 10 K) | ±5 K over heating zone |
| Power Supply | 1-phase, 1.8 kW |
| Weight | 25–45 kg |
| Construction Material | C 530 high-alumina refractory tube |
| Thermocouple Type | S-type (detachable from support) |
| Mounting Flexibility | Adjustable height & tilt angle (horizontal, vertical, or inclined operation) |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | RHTH |
| Temperature Range | Up to 1600 °C, 1700 °C or 1800 °C |
| Configuration | Horizontal |
| Heating Zone Length | 150–600 mm |
| Uniformity (ΔT ≤ 10 K) | Over Specified Zone |
| Tube Diameter | 50–120 mm |
| Power Supply | 3-phase, 400 V |
| Total Power | 5.4–14.4 kW |
| Net Weight | 70–110 kg |
| Insulation | Vacuum-formed Ceramic Fiber Boards (Low Thermal Mass) |
| Heating Element | Suspended MoSi₂ |
| Thermocouple Type | Type B (PtRh30/PtRh6) |
| Compliance | EN 60519-2 (Temperature Protection Class II) |
| Control Cabinet | Separate Vertical Enclosure with SCR Power Controller & Low-Voltage Transformer |
| Optional Features | Gas/Vacuum Sealing Flanges, Multi-Zone Temperature Control (3–4 Zones), Work-Tube Internal Thermocouple Monitoring, Backflow Prevention Check Valve, Vertical Mounting Kit (RHTV variant) |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | HTCT01/14, HTCT08/16 |
| Max Temperature | 1400 °C / 1500 °C / 1600 °C |
| Chamber Dimensions (W×D×H) | 110×120×120 mm to 170×290×170 mm |
| Chamber Volume | 1.5 L to 8.0 L |
| External Dimensions (W×D×H) | 340×300×460 mm to 450×620×570 mm |
| Power Supply | 1-phase or 3-phase |
| Rated Power | 3.5 kW to 13.0 kW |
| Weight | 18 kg to 60 kg |
| Heating Element | Silicon Carbide (SiC) rods |
| Construction | Double-walled stainless steel housing with fiber insulation |
| Door Type | Top-opening (HTCT series) or front-opening (HTC series) |
| Compliance | EN 60519-2 (thermal protection class 2), optional overtemperature limiter |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | L5/13-LT 15/13 |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1300 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2.4 kW |
| Heating Time to Max Temp | 45 min |
| Heating Method | Dual-Side Radiant Heating |
| Internal Dimensions (W×D×H) | 260 × 340 × 170 mm |
| External Dimensions (W×D×H) | 530 × 625 × 630 mm |
| Net Weight | 70 kg |
| Voltage Supply | Single-Phase 230 V |
| Safety Class | Thermal Protection Level 2 per EN 60519-2 |
| Gas Inlet Port | Rear Wall Mounted |
| Exhaust Port | Rear Wall Mounted |
| Optional Door Configuration | Top-Hinged (LT) or Front-Hinged (L) |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | L 1/12 – LT 40/12 |
| Heating Temperature Range | 1100 °C or 1200 °C |
| Chamber Volume | 1–40 L |
| Power Supply | 1-phase (230 V) or 3-phase (400 V) |
| Heating Configuration | Dual-sided ceramic heating plates (triple-sided for L 24/11 – LT 40/12) |
| Insulation | High-purity alumina-silica safety fiber |
| Construction | Double-walled stainless steel housing (brushed finish) |
| Door Options | Front-opening (L) or top-opening (LT) |
| Safety Compliance | EN 60519-2, Thermal Protection Class 2 |
| Data Logging | NTLog via USB flash drive |
| Optional Accessories | Gas purge interface, exhaust chimney with fan/catalyst, VCD process control software |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | LE1/11–LE14/11 |
| Max Temperature | 1100 °C |
| Operating Temperature | 1050 °C |
| Heating Configuration | Dual-sided, heating elements embedded in quartz tubes |
| Insulation | Multi-layer ceramic fiber board |
| Enclosure | Double-walled brushed stainless steel |
| Door Type | Front-opening |
| Exhaust Port | Rear wall-mounted |
| Overtemperature Protection | EN 60519-2 compliant, Class 2 thermal protection with adjustable cutoff temperature |
| Gas Inlet | Rear-mounted manual gas connection |
| Control System | Controltherm MV software-enabled process control and data logging |
| Power Supply | Single-phase |
| Weight | 10–40 kg (model-dependent) |
| Dimensions & Volume | Model-specific (e.g., LE1/11: 90×115×110 mm internal, 1290×280×430 mm external, 1.5 L volume, 1.5 kW) |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model Range | LHT 02/16, LHT 04/16, LHT 08/16, LHT 02/17, LHT 04/17, LHT 08/17, LHT 02/18, LHT 04/18, LHT 08/18 |
| Max Operating Temperature | 1600 °C / 1750 °C / 1800 °C |
| Chamber Volume | 2 L / 4 L / 8 L |
| Internal Dimensions (W×D×H) | 90×150×150 mm to 150×300×150 mm |
| External Dimensions (W×D×H) | 470×630×760 mm to 470×810×760 mm |
| Power Supply | 1-phase (3.0–3.6 kW) or 3-phase (5.2–9.0 kW) |
| Heating Element | MoSi₂ (Molybdenum Disilicide) |
| Thermal Insulation | High-purity ceramic fiber |
| Temperature Sensor | Type B thermocouple |
| Overtemperature Protection | EN 60519-2 compliant dual-stage safety limiter (Class 2 thermal protection) |
| Cooling | Dual-wall steel housing with forced-air cooling |
| Gas Interface | Standard flanged inlet for inert or reducing atmospheres |
| Control System | SCR-based phase-angle power regulation with Controltherm MV software integration |
| Brand | EYELA |
|---|---|
| Origin | Germany |
| Model | LV3/11 |
| Max. Operating Temperature | 1100 °C |
| Internal Dimensions (W×D×H) | 160 × 140 × 100 mm |
| Chamber Volume | 3 L |
| External Dimensions (W×D×H) | 385 × 360 × 735 mm |
| Power Supply | 1-phase, 1.2 kW |
| Net Weight | 20 kg |
| Air Exchange Rate | ≥6 air changes/min |
| Heating Method | Dual-sided ceramic heating plates with embedded resistance wire |
| Insulation | High-purity vacuum-formed fiber modules |
| Safety | EN 60519-2 compliant overtemperature protection (Class 2), adjustable cutoff temperature |
| Control System | Controltherm MV software-enabled process monitoring and data logging |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model Range | LT5/11HA, LT9/11HA, LT15/11HA |
| Max Temperature | 1100 °C |
| Chamber Dimensions (W×D×H) | 200×160×130 mm (LT5), 230×230×170 mm (LT9), 230×330×170 mm (LT15) |
| Chamber Volume | 5 L, 9 L, 15 L |
| External Dimensions (W×D×H) | 470×520×540 mm (LT5), 550×570×480 mm (LT9), 650×570×480 mm (LT15) |
| Electrical Connection | 230 V, 1-phase |
| Power Rating | 2.4 kW (LT5), 3.0 kW (LT9), 3.6 kW (LT15) |
| Net Weight | 66 kg (LT5/LT9), 75 kg (LT15) |
| Heating System | Dual-sided ceramic heating plates with embedded resistance wire |
| Insulation | Vacuum-reinforced fiber modules |
| Door Type | Top-opening (lift-up) |
| Air Circulation | Integrated low-noise centrifugal fan |
| Exhaust | Rear wall vent port + optional chimney assembly with fan or catalytic converter |
| Overtemperature Protection | EN 60519-2 compliant thermal limiter (Class 2), independent cut-off at preset safety threshold |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | L, LT 9/11/SKM |
| Max. Operating Temperature | 1100 °C |
| Internal Dimensions (W×D×H) | 230 × 240 × 170 mm |
| Chamber Volume | 9 L |
| External Dimensions (W×D×H) | 490 × 505 × 580 mm |
| Electrical Connection | 1-phase, 230 V, 50 Hz |
| Power Rating | 3.4 kW |
| Net Weight | 90 kg |
| Heating Element | Embedded Ceramic-Sheathed Resistance Wire |
| Chamber Material | Corrosion-Resistant Ceramic Fiber Liner with Smooth, Non-Shedding Surface |
| Door Options | Front-Opening (L) or Top-Opening (LT) |
| Air Inlet | Adjustable on Door |
| Exhaust Port | Rear Wall-Mounted |
| Safety | Dual Overtemperature Protection per EN 60519-2 (Class 2 Thermal Protection), Cut-off Setpoint Configurable |
| Optional Accessories | Catalytic Exhaust System, Forced-Air Exhaust Fan, Gas Inlet Fitting for Inert/Reducing Atmospheres |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | RSH |
| Heating Configuration | Single-zone or Three-zone |
| Max Operating Temperature | 1100 °C or 1300 °C |
| External Dimensions (W×D×H, mm) | up to 1170 × 490 × 630 |
| Tube Diameter Ø | 50–170 mm |
| Tube Length | 250–1000 mm |
| Uniformity Zone | ±5 K over specified length |
| Power Supply | 1-phase (230 V) or 3-phase (400 V, 3/N/PE) |
| Total Power | 1.9–13.7 kW |
| Weight | 25–491 kg |
| Heating Element | Free-radiating, mounted on support tube |
| Thermocouple Type | Type N (≤1100 °C) or Type S (≤1300 °C) |
| Controller | Nabertherm NTLog-capable, wall- or cabinet-mounted, USB data logging |
| Compliance | CE-marked, designed per IEC 61000-6-2/-4, EN 60519-1 (safety of industrial electroheating equipment) |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | N-Series |
| Maximum Temperature | 1280 °C |
| Heating Configuration | Triple-Sided (Left, Right, Bottom) |
| Insulation | Multi-Layer Refractory Brick Structure |
| Power Supply | 1-Phase (3.0–5.5 kW) or 3-Phase (6.4–25.0 kW) |
| Weight | 60–480 kg |
| Compliance | CE, EN 61000-6-3, EN 61000-6-4, IEC 61000-4-2/4/5/6 |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | NA Series |
| Max Temperature | 450 °C / 650 °C / 850 °C |
| Internal Dimensions (W×D×H, mm) | 290×420×260 to 750×1000×750 |
| Chamber Volume | 15–500 L |
| External Dimensions (W×D×H, mm) | 470×790×460 to 1886×2010×310 |
| Power Supply | 1-phase or 3-phase, 2.8–31.0 kW |
| Weight | 60–1030 kg |
| Airflow | Horizontal forced convection, left-swing rotating door |
| Temp Uniformity | ±4 °C (±7 °C for N 15/65 HA) |
| Compliance | DIN 17052-1 |
| Controller | Nabertherm NTLog with USB data logging |
Show next