Empowering Scientific Discovery

Dongnan Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelLH15/12–LF120/14
Max. Temperature1200–1400 °C
Chamber Dimensions (W×D×H)250×250×250 mm to 500×500×500 mm
Chamber Volume15–216 L
External Dimensions (W×D×H)680×860×1170 mm to 990×1280×1530 mm
Power Supply3-phase, 5.0–26.0 kW
Weight150–470 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelLHT/LB
Max. Temperature1650 °C
Chamber Dimensions (Ø × H)Ø185 × 185 mm (LHT 02/17 LB) / Ø260 × 260 mm (LHT 16/17 LB)
Chamber Volume2 L / 16 L
External Dimensions (W × D × H)390 × 590 × 765 mm / 650 × 1250 × 1980 mm
Power Supply3.4 kW (1-phase) / 12.0 kW (3-phase)
Weight50 kg / 410 kg
Heating ElementMolybdenum Disilicide (MoSi₂)
Temperature Uniformity≤ ±5 °C (at 1600 °C, steady state)
Control SystemSCR-controlled S-type thermocouple with overtemperature protection per EN 60519-2 Class 2
OptionalProtective Gas Inlet, Manual/Automatic Gas Supply, Adjustable Bottom Air Intake, Stackable Crucible Supports, Controltherm MV Process Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelR Series
Max Operating Temperature1200 °C or 1300 °C
Tube ID50–120 mm
Heating Zone Length250–1000 mm
External Dimensions (W×D×H)up to 1300 mm × 1170 mm × 460 mm
Power Supply1-phase (1.6–2.3 kW) or 3-phase (6.5–11.5 kW)
Weight22–89 kg
Control SystemHiProSystem (3-zone for models ≥750 mm heating length, 1300 °C), integrated S-type thermocouple, overtemperature protection per EN 60519-2 Class 2
Atmosphere Optionsinert gas, vacuum-compatible configurations available
Software IntegrationControltherm MV for process monitoring, logging, and compliance-ready data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelRT
Max. Operating Temperature1100 °C / 1300 °C / 1500 °C
Tube Diameter (Ø)50–150 mm
Heating Zone Length250–360 mm
Uniformity (ΔT @ 10 K)±5 K over heating zone
Power Supply1-phase, 1.8 kW
Weight25–45 kg
Construction MaterialC 530 high-alumina refractory tube
Thermocouple TypeS-type (detachable from support)
Mounting FlexibilityAdjustable height & tilt angle (horizontal, vertical, or inclined operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelRHTH
Temperature RangeUp to 1600 °C, 1700 °C or 1800 °C
ConfigurationHorizontal
Heating Zone Length150–600 mm
Uniformity (ΔT ≤ 10 K)Over Specified Zone
Tube Diameter50–120 mm
Power Supply3-phase, 400 V
Total Power5.4–14.4 kW
Net Weight70–110 kg
InsulationVacuum-formed Ceramic Fiber Boards (Low Thermal Mass)
Heating ElementSuspended MoSi₂
Thermocouple TypeType B (PtRh30/PtRh6)
ComplianceEN 60519-2 (Temperature Protection Class II)
Control CabinetSeparate Vertical Enclosure with SCR Power Controller & Low-Voltage Transformer
Optional FeaturesGas/Vacuum Sealing Flanges, Multi-Zone Temperature Control (3–4 Zones), Work-Tube Internal Thermocouple Monitoring, Backflow Prevention Check Valve, Vertical Mounting Kit (RHTV variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelHTCT01/14, HTCT08/16
Max Temperature1400 °C / 1500 °C / 1600 °C
Chamber Dimensions (W×D×H)110×120×120 mm to 170×290×170 mm
Chamber Volume1.5 L to 8.0 L
External Dimensions (W×D×H)340×300×460 mm to 450×620×570 mm
Power Supply1-phase or 3-phase
Rated Power3.5 kW to 13.0 kW
Weight18 kg to 60 kg
Heating ElementSilicon Carbide (SiC) rods
ConstructionDouble-walled stainless steel housing with fiber insulation
Door TypeTop-opening (HTCT series) or front-opening (HTC series)
ComplianceEN 60519-2 (thermal protection class 2), optional overtemperature limiter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelL5/13-LT 15/13
TypeBox-Type Muffle Furnace
Max Temperature1300 °C
Temperature Control Accuracy±1 °C
Max Power2.4 kW
Heating Time to Max Temp45 min
Heating MethodDual-Side Radiant Heating
Internal Dimensions (W×D×H)260 × 340 × 170 mm
External Dimensions (W×D×H)530 × 625 × 630 mm
Net Weight70 kg
Voltage SupplySingle-Phase 230 V
Safety ClassThermal Protection Level 2 per EN 60519-2
Gas Inlet PortRear Wall Mounted
Exhaust PortRear Wall Mounted
Optional Door ConfigurationTop-Hinged (LT) or Front-Hinged (L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelL 1/12 – LT 40/12
Heating Temperature Range1100 °C or 1200 °C
Chamber Volume1–40 L
Power Supply1-phase (230 V) or 3-phase (400 V)
Heating ConfigurationDual-sided ceramic heating plates (triple-sided for L 24/11 – LT 40/12)
InsulationHigh-purity alumina-silica safety fiber
ConstructionDouble-walled stainless steel housing (brushed finish)
Door OptionsFront-opening (L) or top-opening (LT)
Safety ComplianceEN 60519-2, Thermal Protection Class 2
Data LoggingNTLog via USB flash drive
Optional AccessoriesGas purge interface, exhaust chimney with fan/catalyst, VCD process control software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelLE1/11–LE14/11
Max Temperature1100 °C
Operating Temperature1050 °C
Heating ConfigurationDual-sided, heating elements embedded in quartz tubes
InsulationMulti-layer ceramic fiber board
EnclosureDouble-walled brushed stainless steel
Door TypeFront-opening
Exhaust PortRear wall-mounted
Overtemperature ProtectionEN 60519-2 compliant, Class 2 thermal protection with adjustable cutoff temperature
Gas InletRear-mounted manual gas connection
Control SystemControltherm MV software-enabled process control and data logging
Power SupplySingle-phase
Weight10–40 kg (model-dependent)
Dimensions & VolumeModel-specific (e.g., LE1/11: 90×115×110 mm internal, 1290×280×430 mm external, 1.5 L volume, 1.5 kW)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
Model RangeLHT 02/16, LHT 04/16, LHT 08/16, LHT 02/17, LHT 04/17, LHT 08/17, LHT 02/18, LHT 04/18, LHT 08/18
Max Operating Temperature1600 °C / 1750 °C / 1800 °C
Chamber Volume2 L / 4 L / 8 L
Internal Dimensions (W×D×H)90×150×150 mm to 150×300×150 mm
External Dimensions (W×D×H)470×630×760 mm to 470×810×760 mm
Power Supply1-phase (3.0–3.6 kW) or 3-phase (5.2–9.0 kW)
Heating ElementMoSi₂ (Molybdenum Disilicide)
Thermal InsulationHigh-purity ceramic fiber
Temperature SensorType B thermocouple
Overtemperature ProtectionEN 60519-2 compliant dual-stage safety limiter (Class 2 thermal protection)
CoolingDual-wall steel housing with forced-air cooling
Gas InterfaceStandard flanged inlet for inert or reducing atmospheres
Control SystemSCR-based phase-angle power regulation with Controltherm MV software integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA
OriginGermany
ModelLV3/11
Max. Operating Temperature1100 °C
Internal Dimensions (W×D×H)160 × 140 × 100 mm
Chamber Volume3 L
External Dimensions (W×D×H)385 × 360 × 735 mm
Power Supply1-phase, 1.2 kW
Net Weight20 kg
Air Exchange Rate≥6 air changes/min
Heating MethodDual-sided ceramic heating plates with embedded resistance wire
InsulationHigh-purity vacuum-formed fiber modules
SafetyEN 60519-2 compliant overtemperature protection (Class 2), adjustable cutoff temperature
Control SystemControltherm MV software-enabled process monitoring and data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
Model RangeLT5/11HA, LT9/11HA, LT15/11HA
Max Temperature1100 °C
Chamber Dimensions (W×D×H)200×160×130 mm (LT5), 230×230×170 mm (LT9), 230×330×170 mm (LT15)
Chamber Volume5 L, 9 L, 15 L
External Dimensions (W×D×H)470×520×540 mm (LT5), 550×570×480 mm (LT9), 650×570×480 mm (LT15)
Electrical Connection230 V, 1-phase
Power Rating2.4 kW (LT5), 3.0 kW (LT9), 3.6 kW (LT15)
Net Weight66 kg (LT5/LT9), 75 kg (LT15)
Heating SystemDual-sided ceramic heating plates with embedded resistance wire
InsulationVacuum-reinforced fiber modules
Door TypeTop-opening (lift-up)
Air CirculationIntegrated low-noise centrifugal fan
ExhaustRear wall vent port + optional chimney assembly with fan or catalytic converter
Overtemperature ProtectionEN 60519-2 compliant thermal limiter (Class 2), independent cut-off at preset safety threshold
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelL, LT 9/11/SKM
Max. Operating Temperature1100 °C
Internal Dimensions (W×D×H)230 × 240 × 170 mm
Chamber Volume9 L
External Dimensions (W×D×H)490 × 505 × 580 mm
Electrical Connection1-phase, 230 V, 50 Hz
Power Rating3.4 kW
Net Weight90 kg
Heating ElementEmbedded Ceramic-Sheathed Resistance Wire
Chamber MaterialCorrosion-Resistant Ceramic Fiber Liner with Smooth, Non-Shedding Surface
Door OptionsFront-Opening (L) or Top-Opening (LT)
Air InletAdjustable on Door
Exhaust PortRear Wall-Mounted
SafetyDual Overtemperature Protection per EN 60519-2 (Class 2 Thermal Protection), Cut-off Setpoint Configurable
Optional AccessoriesCatalytic Exhaust System, Forced-Air Exhaust Fan, Gas Inlet Fitting for Inert/Reducing Atmospheres
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelRSH
Heating ConfigurationSingle-zone or Three-zone
Max Operating Temperature1100 °C or 1300 °C
External Dimensions (W×D×H, mm)up to 1170 × 490 × 630
Tube Diameter Ø50–170 mm
Tube Length250–1000 mm
Uniformity Zone±5 K over specified length
Power Supply1-phase (230 V) or 3-phase (400 V, 3/N/PE)
Total Power1.9–13.7 kW
Weight25–491 kg
Heating ElementFree-radiating, mounted on support tube
Thermocouple TypeType N (≤1100 °C) or Type S (≤1300 °C)
ControllerNabertherm NTLog-capable, wall- or cabinet-mounted, USB data logging
ComplianceCE-marked, designed per IEC 61000-6-2/-4, EN 60519-1 (safety of industrial electroheating equipment)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelN-Series
Maximum Temperature1280 °C
Heating ConfigurationTriple-Sided (Left, Right, Bottom)
InsulationMulti-Layer Refractory Brick Structure
Power Supply1-Phase (3.0–5.5 kW) or 3-Phase (6.4–25.0 kW)
Weight60–480 kg
ComplianceCE, EN 61000-6-3, EN 61000-6-4, IEC 61000-4-2/4/5/6
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelNA Series
Max Temperature450 °C / 650 °C / 850 °C
Internal Dimensions (W×D×H, mm)290×420×260 to 750×1000×750
Chamber Volume15–500 L
External Dimensions (W×D×H, mm)470×790×460 to 1886×2010×310
Power Supply1-phase or 3-phase, 2.8–31.0 kW
Weight60–1030 kg
AirflowHorizontal forced convection, left-swing rotating door
Temp Uniformity±4 °C (±7 °C for N 15/65 HA)
ComplianceDIN 17052-1
ControllerNabertherm NTLog with USB data logging
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0