| Brand | Lovibond® (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Product Type | Certified Liquid Color Reference Standards |
| Compliance | AOCS, ASTM D1209/D5386/D6166, ISO 6271, EBC 1.3, Gardner ASTM D1544, Pt-Co (APHA/Hazen) ASTM D1209, Saybolt ASTM D156 |
| Format | 5¼" (133 mm) cylindrical glass cells |
| Shelf Life | 12 months from date of manufacture |
| Traceability | NIST-traceable spectrophotometric validation |
| Packaging | Individually labeled, amber glass vials with tamper-evident seals |
| Uncertainty | ±0.1 color unit (RYBN), ±1 APHA unit (Pt-Co), ±0.2 Gardner unit |
| Brand | Lovibond / Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | ICx |
| Measurement Principle | Benchtop Transmittance Spectrophotometry |
| Standards Compliance | ASTM D1209, ASTM D5386, ISO 6271, ASTM E313 |
| Color Scales | Pt-Co/Hazen/APHA, CIEL*a*b*, Yellowness Index (YI) |
| Repeatability (Instrument) | ±0.5 Pt-Co (0–20), ±2 Pt-Co (>20) |
| Measurement Time | <10 s |
| Light Source | 12 V / 20 W Halogen Lamp (User-Replacable) |
| Sample Chamber | Sealed, Laser-Etched, Chemically Resistant |
| Optical Path Length Range | 0.1–152.4 mm |
| Display | 4.3" Full-Color LCD |
| Data Storage Capacity | >100,000 Measurements |
| Interface | USB, RS232 |
| Power Input | 110–250 V AC, 60 W, External 24 V Adapter |
| Dimensions (W×H×D) | 301 × 152 × 331 mm |
| Net Weight | 5.2 kg |
| Housing Material | Anodized Aluminum with Chemical-Resistant Textured Coating |
| Optical Components | Precision Glass Optics |
| Baseline Calibration | One-Touch Automatic |
| Illuminants & Observer | CIE Standard Illuminants A, C, D65 |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Certifications | CE, RoHS, WEEE |
| Warranty | 2 Years (Excluding Light Source and Consumables) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Comparator 3000 Series |
| Measurement Principle | Tristimulus Visual Comparison Against Certified Glass Standards |
| Light Source | CIE-A Compliant Halogen Tungsten Lamp (2856 K) |
| Viewing Field | Triple-Field Simultaneous Comparison |
| Standard Compliance | ASTM D1544, ASTM D1500, ASTM D6045, AOCS Cc 13a-43, DIN EN ISO 4630-1, GB/T 4928-2001, ISO 2049, IP 196 |
| Optical Path Lengths | 10.65 mm (Gardner, FAC), 25 mm (EBC), 33 mm (ASTM) |
| Included Accessories | Model-Specific Certified Glass Color Discs, Calibration Certificate Traceable to NPL/UKAS |
| Brand | Lovibond® (Tintometer®) |
|---|---|
| Origin | United Kingdom |
| Product Type | Certified Reference Filter Sets for Visual and Instrumental Color Measurement |
| Compliance | AOCS, ASTM, EBC, EP, USP, Pfund, Gardner, Saybolt, Pt-Co/Hazen, FAC, CIE xyY, IP Units, Klett, β-Carotene, Chlorophyll A, FAC, EBC Brown/Yellow/Green/Red/Yellow Series |
| Configuration | Pre-assembled, instrument-specific filter kits with NIST-traceable calibration certificates |
| Certification | Individually certified with measured color values and stated uncertainty per ISO/IEC 17025-accredited methodology |
| Brand | Lovibond/Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | Model Fx (PFXeo) |
| Light Source | Tungsten-Halogen Lamp |
| Wavelength Range | 380–780 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | <15 nm |
| Photometric Range | 0–100% Transmittance (T) |
| Photometric Linearity | ±0.01% T |
| Stray Light | <0.01% T |
| Repeatability | ±0.5% T |
| Detector Type | Spectrophotometric |
| Housing Material | Anodized Aluminum |
| Dimensions | 301 mm (W) × 152 mm (H) × 331 mm (D) |
| Weight | 5.16 kg |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing) |
| Storage Environment | −20–85 °C, ≤90% RH (non-condensing) |
| Power Supply | 190–240 V AC |
| Data Interfaces | USB, RS-232 |
| Certifications | CE |
| Supported Languages | English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese |
| Compliant Standards | ISO 15305, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, BS 684 Section 2.20, MS 252 Part 16, IP 17, GB/T 22460-2008, Lovibond® RYBN, Lovibond RY10:1 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Comparator 2000 Series |
| Compliance Standards | ASTM D1209, ASTM D1500, ASTM D6045, ISO 2049, IP 196, EBC, IFU, Ph. Eur. 2.2.2, USP, DIN 6162, IMSI |
| Light Source Compatibility | Daylight 2000 Illumination System (optional, recommended for critical measurements) |
| Measurement Principle | Visual color comparison against standardized glass color standards |
| Application Scope | Pharmaceuticals, Clinical Diagnostics, Food & Beverage, Petrochemicals, Water & Wastewater, Edible Oils & Fats |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | MODEL-F |
| Measurement Principle | Dual-field visual comparison against Lovibond® RYBN glass filter standards |
| Color Scale | Lovibond Red (R): 0.1–79.9, Yellow (Y): 0.1–79.9, Blue (B): 0.1–49.9, Neutral (N): 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Twin 12 V / 10 W tungsten-halogen lamps |
| Illumination | Daylight-mimicking (CIE Standard Illuminant C approx.) with integrated blue filter for spectral consistency |
| Optical System | Precision prism-based dual-view field with standardized viewing geometry |
| Sample Path Length | Adjustable from 0.1 to 153 mm (0.004 to 6 in) |
| Power Supply | 220 V AC / 12 V DC adapter |
| Dimensions & Weight | 330 × 410 × 230 mm |
| Certifications | CE compliant |
| Accessories | Interchangeable R/Y/B/N filter discs (e.g., Part Nos. 180200, 180300–180400), RYBN standard filter sets (184000–187000) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 / PFXi950 / PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Colorimetric Repeatability | Δx,y ≤ ±0.0002 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–153 mm (0.004–6 in) |
| Filter Set | 16 Interference Filters |
| Data Storage Capacity | 100,000 Measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 Backlit LCD |
| Keypad | 23 Membrane Keys with Audible Feedback |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Power Supply | 90–240 V AC (External Adapter) |
| Dimensions | 515 × 196 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| GLP Features | Timestamped Audit Trail, User ID, Sample ID, Calibration Log |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Material | Optical Glass (W600, W680) or Borosilicate Glass (W600-B) |
| Dimensions | 21 mm × 40 mm (W600 series) |
| Max. Operating Temperature | 40 °C (optical glass), 100 °C (borosilicate) |
| Compatible Instruments | Lovibond PFXi/PFX-195, 880, 950, 995, Model F, Comparator 2000+, Comparator 3000 |
| Pathlength Options | 2.5 mm to 6" (6.35 mm to 152.4 mm), including fractional inch and metric increments |
| Light Path Tolerance | ±0.05 mm per ISO 3664:2009 reference compliance |
| Brand | Lovibond / Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | AF710-3 |
| Compliance | AOCS Cc 13b-45, ASTM E313, ASTM D848 |
| Sample Cell | Flat-bottom glass tube with calibrated oil column markings at ½", 1", and 5¼" |
| Optical Path | Fixed-path visual comparison system |
| Color Scale | AOCS-Tintometer® RY (Red-Yellow) scale, distinct from standard Lovibond® RYBN |
| Light Shielding | Integrated dual-tube holder with side-light exclusion design |
| Intended Use | Visual color assessment of transparent to semi-transparent liquids in edible oils, fats, petrochemicals, waxes, and distilled spirits |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 & EC3000 |
| Light Source | White LED (25-year lifetime) |
| Detector | Trichromatic sensor |
| Display | 3.5-inch TFT color LCD, 320×240 resolution, 24-bit color depth |
| Operation Modes | Resistive touchscreen + physical keypad |
| Sample Holder | W100-series cuvette slots (for EC and W100 cuvettes) |
| Housing | Flame-retardant ABS, 106 × 210 × 57 mm (W × D × H) |
| Interface | USB 2.0 (Mini-B) |
| Power Supply | 4 × AA batteries or USB bus power |
| Storage Capacity | ≥20,000 test results |
| Max. Sample Temperature | 80 °C |
| EC2000 Pt-Co Range | 0–500 Pt-Co, Resolution: 1 Pt-Co, Repeatability: ±3% or ±1 Pt-Co (whichever greater), Pathlength: 50 mm, Standard: ASTM D1209 |
| EC2000 Gardner Range | 0–18 Gardner, Resolution: 0.1 Gardner, Repeatability: ±0.2 Gardner, Pathlength: 10 mm, Standards: ASTM D1544, D6166 |
| EC3000 ASTM D1500 Range | 0–8, Resolution: 0.1, Repeatability: ±0.1, Pathlength: 33 mm, Standards: ASTM D1500, D6045 |
| EC3000 Saybolt Range | −16 to +30 Saybolt, Resolution: 1 Saybolt, Repeatability: ±1 Saybolt, Pathlength: 50 mm, Standards: ASTM D156, D6045 |
| Viewing Field | Dual-field (EC2000) / Triple-field (EC3000) |
| Cuvettes | W100 plastic and glass cuvettes (50 mm, 33 mm, 10 mm pathlengths) |
| Calibration Standards | Pre-filled 60 mL reference solutions and certified EC-series interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi-195 |
| Optical Configuration | 9-band interference filter photometer |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | Δx,y ≤ ±0.0004 |
| Measurement Time | <30 s |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–50 mm |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 VAC (external adapter) |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Calibration | One-touch automated baseline calibration |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Product Type | Nesslerization-Compatible Glass Color Comparator Tubes |
| Model Designations | AF228, DB420, AF262, DB421, AF306, DB423, AF306/P, DB424/13.5 |
| Tube Format | Paired Sets (Matched Optical Path Length) |
| Material | Borosilicate Glass, ASTM E2020-22 Compliant |
| Nominal Path Length | 10 mm, 13.5 mm, 20 mm, 25 mm, 50 mm (Model-Dependent) |
| Calibration Traceability | NIST-Traceable Reference Standards Available |
| Compliance | ISO 7887, ASTM D1209, ASTM D5391, USP <631>, EN ISO 7887-2 |