| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ Benchtop |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm |
| Resolution (Conductivity) | 0.01 µS/cm (auto-ranging) |
| Accuracy (Conductivity) | ±0.5% of reading |
| Temperature Range | 0–105 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Linear, 0.00–10.00 %/°C |
| Reference Temp | 20 °C or 25 °C |
| TDS Range | 0.01 mg/L to 300 g/L |
| Salinity Range | 0.00–42 psu |
| Data Storage | 200 measurement records + current calibration data |
| Interfaces | RS232 and USB |
| Electrode Included | LE703 (for aqueous samples, medium-to-high conductivity) |
| Calibration Standards Supplied | 1413 µS/cm and 12.88 mS/cm pre-filled pouches |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Application | Laboratory |
| Conductivity Range | 0.000 µS/cm to 2,000 mS/cm |
| TDS Range | 0.00 mg/L to 1,000 g/L |
| Resistivity Range | 0.00 to 100.0 MΩ·cm |
| Salinity Range | 0.00 to 80.00 PSU |
| Temperature Range | –30.0 to 130.0 °C |
| pH Range | –2.000 to 20.000 |
| mV Range | –2,000.0 to 2,000.0 mV |
| Ion Concentration (pX) | –2.000 to 20.000 |
| Resolution (pH/pX) | 0.001 |
| Accuracy (pH) | ±0.002 |
| Temperature Accuracy | ±0.1 °C (0–100 °C) |
| Calibration | Up to 5-point pH/ion, 1–2-point conductivity, manual or auto electrode constant determination |
| Data Storage | GLP-compliant with timestamp, sample ID, electrode ID, user ID |
| IP Rating | IP54 |
| Display | 7-inch color touchscreen |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm |
| Salinity Range | 0.00–42 psu |
| Temperature Range | 0–105 °C |
| Minimum Conductivity Resolution | 0.01 µS/cm |
| TDS Range | 0.01 mg/L to 300 g/L |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Linear, 0.00–10.00 %/°C, reference temperatures 20 °C and 25 °C |
| Data Storage | 200 measurement records + current calibration data |
| Interface | RS232 and USB |
| Electrode Compatibility | LE703 (included) |
| Compliance | Designed for GLP-compliant workflows with audit-ready calibration logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ pH/mV |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| pH Measurement Range | -2.00 to 16.00 |
| mV Measurement Range | ±2000 mV |
| Conductivity Range | -2.00 to 16.00 mS/cm (as configurable parameter) |
| Salinity Range | 0.00–42.00 psu |
| Temperature Range | 0.0 to 105.0 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| pH Resolution/Accuracy | 0.01 / ±0.01 |
| Data Storage Capacity | 200 measurement records + current calibration data |
| Calibration Points | Up to 5-point pH calibration |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Interface | RS232 and USB |
| Predefined Buffer Sets | 4 standard groups (e.g., DIN, NIST, US, TECH) |
| Electrode Compatibility | Universal BNC + reference input |
| Audible Signal | Yes |
| Display | High-contrast monochrome LCD with icon-based status indicators |