Empowering Scientific Discovery

Dongnan Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelMATRIX Delta Plus
Max Load0.3 kg
Timer Range1 s – 6000 min
Operating ModesTimed, Continuous, Programmable (incl. Ramp)
Temperature Range−10 °C to 110 °C
Temp. Control Accuracy±0.5 °C
Temp. Uniformity±0.5 °C
Heating Rate5.5 °C/min
Cooling Rate2 °C/min (within 30 °C below ambient)
Heating Power100 W
Cooling Power72 W
DisplayTFT touchscreen
InterfacesRS232, USB
Enclosure RatingIP21
Dimensions (W×D×H)216 × 127 × 351 mm
Weight9.5 kg
Ambient Operating Conditions5–40 °C, ≤80% RH
Safety Cut-off145 °C
Power Supply100–240 V AC, 50/60 Hz
Max Input Power230 W
Fuse2× T4A 250V
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModelScan 50 Pro
Power Supply100–240 V~, 50–60 Hz
Max. Power20 W
IP RatingIP20
Petri Dish Diameter55–90 mm
Counting Range0–1999 CFU (manual)
Illumination2nd-generation dark-field indirect LED lighting, 5 intensity levels
Touch SurfaceAdjustable sensitivity capacitive surface
Audio Feedback9 selectable tones, 5 volume levels, headphone jack included
ConnectivityUSB interface for LIMS/SIL integration, barcode reader support
Data ExportCSV (Excel™-compatible), plain text (Word™-compatible)
ComplianceISO 7218, FDA Bacteriological Analytical Manual (BAM)
Warranty3 years (upon registration)
Spare Parts Availability10 years
AccessoriesOptional magnifier, detachable glass plate, removable HandPad扶手
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelKB Series
Temperature Range0 °C to +70 °C
Temperature Uniformity at 37 °C±0.2 K
Temperature Fluctuation at 37 °C±0.1 K (KB 130 and larger)
Recovery Time after 30-sec Door Opening at 37 °C3 min
Internal Volume63 L to 1070 L
Power Consumption0.9 kW to 1.5 kW
RefrigerantR-600a
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA
OriginJapan
ModelMMV-1000W
Oscillation ModeVertical or Tilt (0–20° adjustable)
Speed Range20–300 cycles/min (vertical), 20–250 cycles/min (tilt)
Amplitude40 mm
Max Load Capacity7 kg × 2 (including clamps)
Flask CompatibilityStandard clamp: 50–1000 mL
Large clamp50–3000 mL
DisplayDigital cycle counter with memory function
Drive SystemBrushless DC motor
Noise Level≤55 dB(A)
Start/Stop ProfileSoft acceleration/deceleration
Operating ModeTimer or continuous
Power SupplyAC 100–240 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelKT53 / KT115 / KT170
Temperature Range4 °C to 100 °C
Internal Volume53 L / 102 L / 163 L
External Dimensions (W×H×D, mm)660×635×630 / 860×715×655 / 860×1025×655
Internal Dimensions (W×H×D, mm)400×400×334 / 600×455×355 / 600×765×355
Net Weight63 kg / 83 kg / 102 kg
Inner DoorTempered Safety Glass (ESG)
InteriorStainless Steel Construction
Shelving2 Removable Stainless Steel Trays
Stacking CapabilityUp to KT115 Units
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBF56 / BF115 / BF260 / BF720
External Dimensions (W×H×D, mm)560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870
Internal Dimensions (W×H×D, mm)400×440×340 / 550×550×380 / 650×780×510 / 1000×1300×560
Internal Volume (L)59 / 114 / 257 / 734
Net Weight (kg)39 / 54 / 85 / 165
Max. Total Load (kg)70 / 150 / 270 / 120
Max. Load per Shelf (kg)30 / 30 / 40 / 40
Temp. RangeAmbient +8 °C to 100 °C (BF56–BF260)
Temp. Uniformity (±K @37°C)0.2 / 0.3 / 0.2 / 0.3
Temp. Fluctuation (±K @37°C)0.1 across all models
Time to Reach 37°C (min)6 / 8 / 7 / 15
Recovery Time after 30s Door Opening (min @37°C)3 / 3 / 3 / 4
Rated Power (230 V, kW)0.4 / 0.4 / 0.9 / 1.75
Standard/Max. Shelves2/4 / 2/5 / 2/8 / 2/16
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelCB Series
SterilizationDry-heat sterilization (180 °C, 2–4 h)
CO₂ Control Range0–20 % (±0.1 % typical accuracy)
Temperature RangeAmbient +5 °C to 50 °C (±0.1 °C stability at 37 °C)
Humidity ControlActive humidification with integrated water pan and saturation monitoring
Chamber Volume Options53 L to 216 L
ConstructionStainless steel interior (AISI 304), double-wall insulated chamber, HEPA-filtered air circulation (ISO Class 5 compliant)
ComplianceIEC 61010-1, EN 61326-1, CE marked for in vitro diagnostic use (IVDR Annex II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA (Tokyo Rikakikai Co., Ltd.)
OriginJapan
ModelMMS-110 / MMS-210 / MMS-310 / MMS-3010
Oscillation ModeReciprocal (MMS-110), Orbital (MMS-210), Dual-Mode Reciprocal/Orbital (MMS-310 & MMS-3010)
Speed Range20–250 rpm
Amplitude25 mm
Speed Control & DisplayAnalog Knob + Digital LED Display
Safety FeaturesFuse Protection + Motor Overload Circuit
Time Accumulation Function0.1–999.9 h (digital display)
Motor TypeBrushless DC Motor
Operating Ambient Temperature Range4–50 °C
Noise Reduction≥5 dB(A) vs. previous generation
Enclosure CompatibilityCompatible with EYELA FMS/FMC environmental chambers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEsco
OriginSingapore
ModelVIVA
Cabinet ClassType II A2-equivalent
External Dimensions (L×W×H)1423 × 815 × 1510 mm (VA2-4A1-E) / 2030 × 815 × 1510 mm (VA2-6A1-E)
Work Area Dimensions (L×W×H)1270 × 623 × 680 mm (VA2-4A1-E) / 1870 × 620 × 680 mm (VA2-6A1-E)
Inflow Velocity0.45 m/s (90 fpm)
Downflow Velocity0.35 m/s (70 fpm)
Power Supply220–240 VAC, 50/60 Hz
Pre-filterPolyester, 85% arrestance
Final FilterDual ULPA, ≥99% MPPS @ 0.12 µm
Airflow MonitoringReal-time digital sensing with Sentinel microprocessor control
ComplianceISO 14644-1 Class 3 (equivalent to Fed Std 209E Class 1), NSF/ANSI 49 compliant design principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelKBF-S ECO Solid.Line
Temperature Range (with Humidification)0 °C to +70 °C
Humidity Range10 % to 98 % RH
Temperature Uniformity (25 °C / 60 % RH)±0.1 K
Temperature Fluctuation (40 °C / 75 % RH)±0.1 K
Humidity Fluctuation (40 °C / 75 % RH)±0.3 % RH
Recovery Time after 30-sec Door Opening (40 °C / 75 % RH)11–17 min
Internal Volume Options247 L, 400 L, 700 L, 1020 L
Power Consumption (25 °C / 60 % RH)55–90 Wh/h
Noise Level45–49 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModelScan® 4000
Instrument TypeFully Automated Colony Counter
Counting Speed1000 colonies/sec
Camera5 MP Color CCD with 69× Zoom
Minimum Detectable Colony Size0.05 mm
Petri Dish CompatibilityØ 55–150 mm (round), up to 120 mm (square)
Illumination SystemProgrammable White Dome LED with 7 Configurable Modes (top/bottom white/black background)
Inhibition Zone Measurement Accuracy0.1 mm
Color Detection CapacityUp to 7 Colors per Plate
Supported MediaChromogenic Agar, Mueller-Hinton Agar, Blood Agar, Chocolate Agar, PetriFilm™, RIDA™ Count, Compact Dry™, Filter Membranes, Antibiotic Discs & Wells
Data Export FormatsPDF, JPEG, PNG, BMP, Excel™
ComplianceGLP, 21 CFR Part 11, ISO 15189, ISO 7218, ISO 4833-2, NF V08-034, NF V08-100, AOAC 977.27, FDA-BAM
Dimensions (W×D×H)47 × 47 × 64 cm
Weight25 kg
Power Supply100–240 V ∼ 50/60 Hz, 140 W
Required PC SpecWindows 7 SP1 or later, Quad-core Intel i5/i7 or AMD FX-6000+, ≥2.4 GHz, ≥4 GB RAM, Dedicated GPU (AMD/NVIDIA), ≥1280×1024 Display, USB 2.0, CD-ROM Drive
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA (Tokyo Rikakikai Co., Ltd.)
OriginJapan
ModelMMV-1000W
Oscillation ModeVertical or Tilted
Tilt Angle Adjustment0–20°
Oscillation Speed Range20–300 cycles/min (vertical), 20–250 cycles/min (tilted)
Amplitude40 mm
Max Load Capacity~7 kg × 2 (including clamps)
Flask CompatibilityStandard Clamp: 50–1000 mL
Large Clamp50–3000 mL
Noise Level≤55 dB(A)
Drive SystemBrushless DC Motor
Control InterfaceDigital Display with Memory Function (retains last set frequency)
Operation ModesTimed or Continuous
Acceleration/Deceleration ProfileSoft-start and soft-stop ramping
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModelScan 500
Camera1 MP CMOS color
LensM12, 28× zoom
IlluminationAutomatic dark-field system with 6 configurable top/bottom/white/black combinations
Petri Dish CompatibilityØ55–Ø90 mm
Minimum Detectable Colony Diameter0.1 mm
Counting SpeedUp to 1000 colonies/sec
Accuracy≥98%
Inhibition Zone DetectionYes, with ±0.3 mm measurement precision
Standards ComplianceISO 7218, AOAC 977.27, CLSI, EUCAST, CA-SFM (human & veterinary), custom standard support
Software LanguagesEnglish, French, German, Spanish, Japanese, Chinese, Russian
ConnectivityUSB 2.0, LIMS/SIL integration via DataLink® / DataLink Pro®
Data Export FormatsCSV, Excel™, PDF, SCA, BIO, JPEG, PNG, BMP
Regulatory ComplianceFDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access), GLP/GMP-aligned
Power Supply100–240 V~, 50–60 Hz, 20 W max
Dimensions (W×D×H)28.7 × 27.1 × 28.9 cm
Weight8.38 kg
Warranty3 years (registration required)
Spare Parts Availability10 years
Software Updates3 years (excludes validation documentation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelKS 4000i
Orbital Motion TypeCircular
Orbit Diameter20 mm
Max Load Capacity (incl. clamps)20 kg
Motor Input Power82 W
Motor Output Power24 W
Duty CycleContinuous (100 %)
Speed Range10–500 rpm
Speed DisplayLED
Timer FunctionYes
Timer Display7-segment LED
Timer Range1–59,940 min
Operation ModesTimed & Continuous
Pulse ModeNo
Tabletop BrakeNo
Microplate CompatibilityNot Designed for Microplates
Temperature Control RangeRT +5 °C to 80 °C
Heating Power1000 W
Temperature DisplayYes
Temp Stability (0.2 L H₂O, RT 25 °C, setpoint 37 °C)±0.1 K
Dimensions (W×D×H)580 × 525 × 750 mm
Weight50 kg
Ambient Operating Temp15–32 °C
Max Relative Humidity80 %
Ingress ProtectionIP 30 per DIN EN 60529
RS232 InterfaceYes
Voltage230 / 115 / 100 V
Frequency50/60 Hz
Total Instrument Power Consumption1120 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHT200
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBF
Internal Volume400 L
External Dimensions (W×H×D)1235 × 1025 × 765 mm
Internal Dimensions (W×H×D)1000 × 800 × 500 mm
Net Weight (empty)145 kg
Max. Total Load90 kg
Max. Load per Shelf35 kg
Temperature RangeAmbient +5 °C to 100 °C
Temp. Uniformity (±K @37°C)0.4
Temp. Fluctuation (±K @37°C)0.1
Heating Time to 37°C12 min
Recovery Time (30 s door opening @37°C)5 min
Rated Power (230 V)0.85 kW
Standard Shelves2 (up to 9 optional)
Preheating Chamber TechnologyACT.line™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelCBF Series
Internal Volume170 L / 267 L
Net Weight (empty)95 kg / 125 kg
Max. Total Load30 kg / 40 kg
Max. Load per Shelf10 kg
Rear Wall Clearance100 mm
Side Wall Clearance50 mm
Internal Dimensions (W×H×D)560×600×505 mm / 620×750×575 mm
External Dimensions (W×H×D)680×870×715 mm / 740×1020×785 mm
Temp. RangeRT + 6 °C to 60 °C
Temp. Uniformity±0.4 K @ 37 °C
Temp. Stability±0.1 K @ 37 °C
Temp. Recovery Time (30 s door open)6 min @ 37 °C
Humidity Range50–95 %RH
CO₂ Range0–20 vol.%
CO₂ Sensing PrincipleSingle-beam IR
Rated Power (230 V)1.4 kW / 1.5 kW
Standard/Max. Shelves3/6 or 3/8
Sterilization180 °C dry-heat
Chamber MaterialSeamless stainless steel with shelf reinforcement system
Gas MixingVenturi-type CO₂ injection nozzle
Control InterfaceTouchscreen controller with USB data export, Ethernet, zero-voltage alarm contacts
Data LoggingInternal recorder with open-format measurement values
Safety SystemsCO₂ Fail-Safe pH monitoring, optical & acoustic fault diagnostics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelCB
Internal Volume (L)53 / 170 / 260
Net Weight (kg, empty)53 / 98 / 125
Max Total Load (kg)30 / 30 / 40
Max Load per Shelf (kg)10 / 10 / 10
Rear Wall Clearance (mm)100 / 100 / 100
Side Wall Clearance (mm)50 / 50 / 50
Internal Dimensions (W×H×D, mm)400×400×330 / 560×600×505 / 620×750×575
External Dimensions (W×H×D, mm)528×674×545 / 680×870×715 / 740×1020×785
Temp. RangeRT+4–6°C to 60°C
Temp. Uniformity (±K @37°C)0.3 / 0.3 / 0.4
Temp. Stability (±K @37°C)0.1 / 0.1 / 0.13
Humidity Range90–95% RH
CO₂ Range0–20 vol.%
CO₂ Measurement PrincipleSingle-beam IR sensor
Recovery Time after 30-sec Door Opening (min @37°C)5 / 6 / 6
Rated Power (230 V, kW)0.8 / 1.4 / 1.5
Standard/Max Shelf Quantity2/3 / 3/6 / 3/8
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterScience
OriginFrance
ModelScan 5000 Ai
Camera69 MP Ultra-HD CMOS Color Sensor with Japanese HD Zoom Lens
IlluminationAuto-Configurable 7-Mode LED Dome Lighting (Top/Bottom, White/Black Background)
Petri Dish CompatibilityØ 55–150 mm circular & 120 mm square dishes
Colony Detection Limit≥ 0.03 mm diameter
Counting SpeedUp to 1000 colonies/sec
Zone Measurement Accuracy±0.1 mm
Zone Detection Time2–4 sec for up to 16 antibiotics
Standards ComplianceISO 7218, AOAC 977.27, CLSI, EUCAST, CA-SFM (Human & Veterinary), FDA 21 CFR Part 11
Software LanguagesEnglish, French, German, Spanish, Japanese, Chinese, Russian
Data Export FormatsCSV, Excel™, PDF, JPEG, PNG, BMP, SCA, BIO
System RequirementsWindows 10/11, Intel i7 (2.8 GHz+) or Xeon Gold, NVIDIA RTX 3060/4050+, 16 GB RAM, USB 3.0, 1920×1080+ display
Dimensions (W×D×H)46.4 × 46.4 × 63.1 cm
Net Weight25.15 kg
Warranty3 years (registration required)
Spare Parts Availability10 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelDM750M
Instrument TypeUpright Microscope
IlluminationWhite LED (Transmitted & Reflected Light)
Magnification Range50×–1000×
Objective Turret4-position or 5-position
CondenserAdjustable Abbe condenser for transmitted light
Reflected Light ModuleLED-based with field diaphragm and aperture diaphragm
StageMechanical XY stage with 25–30 mm specimen clamp compatibility
Eyepieces10× widefield (20 mm field number), optional ergonomic viewing tubes (four configurations)
Digital ImagingCompatible with Leica ICC50 HD, DMC2900, and other Leica-certified CMOS/CCD cameras
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelMATRIX Orbital Delta F2.0
Orbit Diameter3 mm
Max Load0.3 kg
Speed Range0–1500 rpm
Min Adjustable Speed300 rpm
Speed Accuracy±30 rpm
Speed Resolution10 rpm steps
Timer Range1 s – 6000 min
Heating RangeRT +4 °C to 100 °C
Heating Power100 W
Temp. Control Accuracy±0.5 °C
Temp. Uniformity±0.5 °C (20–45 °C), ±1.5 °C (>45 °C)
Heating Rate13 °C/min
Sample Capacity24 × 2.0 mL tubes
Dimensions (W×D×H)216 × 158 × 351 mm
Weight9.2 kg
Ambient Operating Conditions5–40 °C, ≤80% RH
Protection ClassIP21
InterfacesRS232, USB
Power Supply100–240 V, 50/60 Hz
Max Input Power240 W
Fuse2 × T4A 250V
Added to wishlistRemoved from wishlist 0
Add to compare
BrandParvo Medics
OriginUSA
ModelTrue One2400
O₂ Analysis Range0–100% or 0–25%
O₂ Accuracy±0.02%
O₂ Response Time200 ms (21% → 16% in 4 L mixing chamber)
CO₂ Analysis MethodNDIR (Non-Dispersive Infrared)
CO₂ Range0–15%
CO₂ Accuracy±0.03% (for 0–10% CO₂)
CO₂ Response Time100 ms
Flow Measurement Accuracy±0.5%
Flow Range0–800 L/min
CalibrationDual-stage (3 L syringe, 16% O₂ / 4% CO₂ gas mixture)
Operating Temperature14–30 °C
Relative Humidity20–80% RH
Warm-up Time30 min
Power Supply100–240 VAC, 50–60 Hz
Software PlatformWindows XP–compatible proprietary metabolic analysis suite
Data ExportNative Excel (.xls) output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModelScanStation
Camera Resolution5 MP
Petri Dish Capacity100 (90 mm)
Imaging IntervalEvery 30 minutes
Temperature Range10–45 °C
Temperature Uniformity±1 °C at 9 internal points
Cooling/Heating TechnologyPeltier modules (compressor-free, fluid-free)
Display23-inch capacitive touchscreen
Operating SystemWindows 10 (integrated PC: Intel Core i7)
Data ExportExcel™
Video PlaybackFull time-lapse with zoom, pause, rewind
Dimensions (W × D × H)136 × 83 × 91 cm (arm attached)
Total Height (incl. storage cabinet)151 cm
Weight287 kg (unit), 59 kg (storage cabinet)
Power Supply100–240 V~, 50–60 Hz
Max Power Consumption2000 W
Environmental LimitsAmbient temperature 18–25 °C
Max Incubation Duration10 days
ComplianceCE, ISO 17025-ready architecture, GLP/GMP data integrity support (audit trail, user access control, electronic signatures via optional FDA 21 CFR Part 11 module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelBD-S 56 / BD-S 115
External Dimensions (W×H×D)560×580×515 mm / 740×790×555 mm
Internal Dimensions (W×H×D)400×400×350 mm / 550×550×390 mm
Internal Volume62 L / 118 L
Net Weight (empty)41 kg / 57 kg
Temperature RangeAmbient +5 °C to 70 °C
Temperature Uniformity (±K @ 37 °C)0.7 / 0.5
Temperature Fluctuation (±K @ 37 °C)0.1 / 0.2
Recovery Time (min @ 37 °C, 30 s door opening)15 / 15
Power Consumption (Wh/h @ 37 °C)25 / 25
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0