| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | MATRIX Delta Plus |
| Max Load | 0.3 kg |
| Timer Range | 1 s – 6000 min |
| Operating Modes | Timed, Continuous, Programmable (incl. Ramp) |
| Temperature Range | −10 °C to 110 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Temp. Uniformity | ±0.5 °C |
| Heating Rate | 5.5 °C/min |
| Cooling Rate | 2 °C/min (within 30 °C below ambient) |
| Heating Power | 100 W |
| Cooling Power | 72 W |
| Display | TFT touchscreen |
| Interfaces | RS232, USB |
| Enclosure Rating | IP21 |
| Dimensions (W×D×H) | 216 × 127 × 351 mm |
| Weight | 9.5 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Safety Cut-off | 145 °C |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Max Input Power | 230 W |
| Fuse | 2× T4A 250V |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | Scan 50 Pro |
| Power Supply | 100–240 V~, 50–60 Hz |
| Max. Power | 20 W |
| IP Rating | IP20 |
| Petri Dish Diameter | 55–90 mm |
| Counting Range | 0–1999 CFU (manual) |
| Illumination | 2nd-generation dark-field indirect LED lighting, 5 intensity levels |
| Touch Surface | Adjustable sensitivity capacitive surface |
| Audio Feedback | 9 selectable tones, 5 volume levels, headphone jack included |
| Connectivity | USB interface for LIMS/SIL integration, barcode reader support |
| Data Export | CSV (Excel™-compatible), plain text (Word™-compatible) |
| Compliance | ISO 7218, FDA Bacteriological Analytical Manual (BAM) |
| Warranty | 3 years (upon registration) |
| Spare Parts Availability | 10 years |
| Accessories | Optional magnifier, detachable glass plate, removable HandPad扶手 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB Series |
| Temperature Range | 0 °C to +70 °C |
| Temperature Uniformity at 37 °C | ±0.2 K |
| Temperature Fluctuation at 37 °C | ±0.1 K (KB 130 and larger) |
| Recovery Time after 30-sec Door Opening at 37 °C | 3 min |
| Internal Volume | 63 L to 1070 L |
| Power Consumption | 0.9 kW to 1.5 kW |
| Refrigerant | R-600a |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | MMV-1000W |
| Oscillation Mode | Vertical or Tilt (0–20° adjustable) |
| Speed Range | 20–300 cycles/min (vertical), 20–250 cycles/min (tilt) |
| Amplitude | 40 mm |
| Max Load Capacity | 7 kg × 2 (including clamps) |
| Flask Compatibility | Standard clamp: 50–1000 mL |
| Large clamp | 50–3000 mL |
| Display | Digital cycle counter with memory function |
| Drive System | Brushless DC motor |
| Noise Level | ≤55 dB(A) |
| Start/Stop Profile | Soft acceleration/deceleration |
| Operating Mode | Timer or continuous |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KT53 / KT115 / KT170 |
| Temperature Range | 4 °C to 100 °C |
| Internal Volume | 53 L / 102 L / 163 L |
| External Dimensions (W×H×D, mm) | 660×635×630 / 860×715×655 / 860×1025×655 |
| Internal Dimensions (W×H×D, mm) | 400×400×334 / 600×455×355 / 600×765×355 |
| Net Weight | 63 kg / 83 kg / 102 kg |
| Inner Door | Tempered Safety Glass (ESG) |
| Interior | Stainless Steel Construction |
| Shelving | 2 Removable Stainless Steel Trays |
| Stacking Capability | Up to KT115 Units |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BF56 / BF115 / BF260 / BF720 |
| External Dimensions (W×H×D, mm) | 560×625×565 / 710×735×605 / 810×965×760 / 1165×1590×870 |
| Internal Dimensions (W×H×D, mm) | 400×440×340 / 550×550×380 / 650×780×510 / 1000×1300×560 |
| Internal Volume (L) | 59 / 114 / 257 / 734 |
| Net Weight (kg) | 39 / 54 / 85 / 165 |
| Max. Total Load (kg) | 70 / 150 / 270 / 120 |
| Max. Load per Shelf (kg) | 30 / 30 / 40 / 40 |
| Temp. Range | Ambient +8 °C to 100 °C (BF56–BF260) |
| Temp. Uniformity (±K @37°C) | 0.2 / 0.3 / 0.2 / 0.3 |
| Temp. Fluctuation (±K @37°C) | 0.1 across all models |
| Time to Reach 37°C (min) | 6 / 8 / 7 / 15 |
| Recovery Time after 30s Door Opening (min @37°C) | 3 / 3 / 3 / 4 |
| Rated Power (230 V, kW) | 0.4 / 0.4 / 0.9 / 1.75 |
| Standard/Max. Shelves | 2/4 / 2/5 / 2/8 / 2/16 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB Series |
| Sterilization | Dry-heat sterilization (180 °C, 2–4 h) |
| CO₂ Control Range | 0–20 % (±0.1 % typical accuracy) |
| Temperature Range | Ambient +5 °C to 50 °C (±0.1 °C stability at 37 °C) |
| Humidity Control | Active humidification with integrated water pan and saturation monitoring |
| Chamber Volume Options | 53 L to 216 L |
| Construction | Stainless steel interior (AISI 304), double-wall insulated chamber, HEPA-filtered air circulation (ISO Class 5 compliant) |
| Compliance | IEC 61010-1, EN 61326-1, CE marked for in vitro diagnostic use (IVDR Annex II) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | MMS-110 / MMS-210 / MMS-310 / MMS-3010 |
| Oscillation Mode | Reciprocal (MMS-110), Orbital (MMS-210), Dual-Mode Reciprocal/Orbital (MMS-310 & MMS-3010) |
| Speed Range | 20–250 rpm |
| Amplitude | 25 mm |
| Speed Control & Display | Analog Knob + Digital LED Display |
| Safety Features | Fuse Protection + Motor Overload Circuit |
| Time Accumulation Function | 0.1–999.9 h (digital display) |
| Motor Type | Brushless DC Motor |
| Operating Ambient Temperature Range | 4–50 °C |
| Noise Reduction | ≥5 dB(A) vs. previous generation |
| Enclosure Compatibility | Compatible with EYELA FMS/FMC environmental chambers |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Model | VIVA |
| Cabinet Class | Type II A2-equivalent |
| External Dimensions (L×W×H) | 1423 × 815 × 1510 mm (VA2-4A1-E) / 2030 × 815 × 1510 mm (VA2-6A1-E) |
| Work Area Dimensions (L×W×H) | 1270 × 623 × 680 mm (VA2-4A1-E) / 1870 × 620 × 680 mm (VA2-6A1-E) |
| Inflow Velocity | 0.45 m/s (90 fpm) |
| Downflow Velocity | 0.35 m/s (70 fpm) |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Pre-filter | Polyester, 85% arrestance |
| Final Filter | Dual ULPA, ≥99% MPPS @ 0.12 µm |
| Airflow Monitoring | Real-time digital sensing with Sentinel microprocessor control |
| Compliance | ISO 14644-1 Class 3 (equivalent to Fed Std 209E Class 1), NSF/ANSI 49 compliant design principles |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF-S ECO Solid.Line |
| Temperature Range (with Humidification) | 0 °C to +70 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity (25 °C / 60 % RH) | ±0.1 K |
| Temperature Fluctuation (40 °C / 75 % RH) | ±0.1 K |
| Humidity Fluctuation (40 °C / 75 % RH) | ±0.3 % RH |
| Recovery Time after 30-sec Door Opening (40 °C / 75 % RH) | 11–17 min |
| Internal Volume Options | 247 L, 400 L, 700 L, 1020 L |
| Power Consumption (25 °C / 60 % RH) | 55–90 Wh/h |
| Noise Level | 45–49 dB(A) |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | Scan® 4000 |
| Instrument Type | Fully Automated Colony Counter |
| Counting Speed | 1000 colonies/sec |
| Camera | 5 MP Color CCD with 69× Zoom |
| Minimum Detectable Colony Size | 0.05 mm |
| Petri Dish Compatibility | Ø 55–150 mm (round), up to 120 mm (square) |
| Illumination System | Programmable White Dome LED with 7 Configurable Modes (top/bottom white/black background) |
| Inhibition Zone Measurement Accuracy | 0.1 mm |
| Color Detection Capacity | Up to 7 Colors per Plate |
| Supported Media | Chromogenic Agar, Mueller-Hinton Agar, Blood Agar, Chocolate Agar, PetriFilm™, RIDA™ Count, Compact Dry™, Filter Membranes, Antibiotic Discs & Wells |
| Data Export Formats | PDF, JPEG, PNG, BMP, Excel™ |
| Compliance | GLP, 21 CFR Part 11, ISO 15189, ISO 7218, ISO 4833-2, NF V08-034, NF V08-100, AOAC 977.27, FDA-BAM |
| Dimensions (W×D×H) | 47 × 47 × 64 cm |
| Weight | 25 kg |
| Power Supply | 100–240 V ∼ 50/60 Hz, 140 W |
| Required PC Spec | Windows 7 SP1 or later, Quad-core Intel i5/i7 or AMD FX-6000+, ≥2.4 GHz, ≥4 GB RAM, Dedicated GPU (AMD/NVIDIA), ≥1280×1024 Display, USB 2.0, CD-ROM Drive |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | MMV-1000W |
| Oscillation Mode | Vertical or Tilted |
| Tilt Angle Adjustment | 0–20° |
| Oscillation Speed Range | 20–300 cycles/min (vertical), 20–250 cycles/min (tilted) |
| Amplitude | 40 mm |
| Max Load Capacity | ~7 kg × 2 (including clamps) |
| Flask Compatibility | Standard Clamp: 50–1000 mL |
| Large Clamp | 50–3000 mL |
| Noise Level | ≤55 dB(A) |
| Drive System | Brushless DC Motor |
| Control Interface | Digital Display with Memory Function (retains last set frequency) |
| Operation Modes | Timed or Continuous |
| Acceleration/Deceleration Profile | Soft-start and soft-stop ramping |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | Scan 500 |
| Camera | 1 MP CMOS color |
| Lens | M12, 28× zoom |
| Illumination | Automatic dark-field system with 6 configurable top/bottom/white/black combinations |
| Petri Dish Compatibility | Ø55–Ø90 mm |
| Minimum Detectable Colony Diameter | 0.1 mm |
| Counting Speed | Up to 1000 colonies/sec |
| Accuracy | ≥98% |
| Inhibition Zone Detection | Yes, with ±0.3 mm measurement precision |
| Standards Compliance | ISO 7218, AOAC 977.27, CLSI, EUCAST, CA-SFM (human & veterinary), custom standard support |
| Software Languages | English, French, German, Spanish, Japanese, Chinese, Russian |
| Connectivity | USB 2.0, LIMS/SIL integration via DataLink® / DataLink Pro® |
| Data Export Formats | CSV, Excel™, PDF, SCA, BIO, JPEG, PNG, BMP |
| Regulatory Compliance | FDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access), GLP/GMP-aligned |
| Power Supply | 100–240 V~, 50–60 Hz, 20 W max |
| Dimensions (W×D×H) | 28.7 × 27.1 × 28.9 cm |
| Weight | 8.38 kg |
| Warranty | 3 years (registration required) |
| Spare Parts Availability | 10 years |
| Software Updates | 3 years (excludes validation documentation) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | KS 4000i |
| Orbital Motion Type | Circular |
| Orbit Diameter | 20 mm |
| Max Load Capacity (incl. clamps) | 20 kg |
| Motor Input Power | 82 W |
| Motor Output Power | 24 W |
| Duty Cycle | Continuous (100 %) |
| Speed Range | 10–500 rpm |
| Speed Display | LED |
| Timer Function | Yes |
| Timer Display | 7-segment LED |
| Timer Range | 1–59,940 min |
| Operation Modes | Timed & Continuous |
| Pulse Mode | No |
| Tabletop Brake | No |
| Microplate Compatibility | Not Designed for Microplates |
| Temperature Control Range | RT +5 °C to 80 °C |
| Heating Power | 1000 W |
| Temperature Display | Yes |
| Temp Stability (0.2 L H₂O, RT 25 °C, setpoint 37 °C) | ±0.1 K |
| Dimensions (W×D×H) | 580 × 525 × 750 mm |
| Weight | 50 kg |
| Ambient Operating Temp | 15–32 °C |
| Max Relative Humidity | 80 % |
| Ingress Protection | IP 30 per DIN EN 60529 |
| RS232 Interface | Yes |
| Voltage | 230 / 115 / 100 V |
| Frequency | 50/60 Hz |
| Total Instrument Power Consumption | 1120 W |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HT200 |
| Pricing | Upon Request |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BF |
| Internal Volume | 400 L |
| External Dimensions (W×H×D) | 1235 × 1025 × 765 mm |
| Internal Dimensions (W×H×D) | 1000 × 800 × 500 mm |
| Net Weight (empty) | 145 kg |
| Max. Total Load | 90 kg |
| Max. Load per Shelf | 35 kg |
| Temperature Range | Ambient +5 °C to 100 °C |
| Temp. Uniformity (±K @37°C) | 0.4 |
| Temp. Fluctuation (±K @37°C) | 0.1 |
| Heating Time to 37°C | 12 min |
| Recovery Time (30 s door opening @37°C) | 5 min |
| Rated Power (230 V) | 0.85 kW |
| Standard Shelves | 2 (up to 9 optional) |
| Preheating Chamber Technology | ACT.line™ |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CBF Series |
| Internal Volume | 170 L / 267 L |
| Net Weight (empty) | 95 kg / 125 kg |
| Max. Total Load | 30 kg / 40 kg |
| Max. Load per Shelf | 10 kg |
| Rear Wall Clearance | 100 mm |
| Side Wall Clearance | 50 mm |
| Internal Dimensions (W×H×D) | 560×600×505 mm / 620×750×575 mm |
| External Dimensions (W×H×D) | 680×870×715 mm / 740×1020×785 mm |
| Temp. Range | RT + 6 °C to 60 °C |
| Temp. Uniformity | ±0.4 K @ 37 °C |
| Temp. Stability | ±0.1 K @ 37 °C |
| Temp. Recovery Time (30 s door open) | 6 min @ 37 °C |
| Humidity Range | 50–95 %RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Sensing Principle | Single-beam IR |
| Rated Power (230 V) | 1.4 kW / 1.5 kW |
| Standard/Max. Shelves | 3/6 or 3/8 |
| Sterilization | 180 °C dry-heat |
| Chamber Material | Seamless stainless steel with shelf reinforcement system |
| Gas Mixing | Venturi-type CO₂ injection nozzle |
| Control Interface | Touchscreen controller with USB data export, Ethernet, zero-voltage alarm contacts |
| Data Logging | Internal recorder with open-format measurement values |
| Safety Systems | CO₂ Fail-Safe pH monitoring, optical & acoustic fault diagnostics |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | CB |
| Internal Volume (L) | 53 / 170 / 260 |
| Net Weight (kg, empty) | 53 / 98 / 125 |
| Max Total Load (kg) | 30 / 30 / 40 |
| Max Load per Shelf (kg) | 10 / 10 / 10 |
| Rear Wall Clearance (mm) | 100 / 100 / 100 |
| Side Wall Clearance (mm) | 50 / 50 / 50 |
| Internal Dimensions (W×H×D, mm) | 400×400×330 / 560×600×505 / 620×750×575 |
| External Dimensions (W×H×D, mm) | 528×674×545 / 680×870×715 / 740×1020×785 |
| Temp. Range | RT+4–6°C to 60°C |
| Temp. Uniformity (±K @37°C) | 0.3 / 0.3 / 0.4 |
| Temp. Stability (±K @37°C) | 0.1 / 0.1 / 0.13 |
| Humidity Range | 90–95% RH |
| CO₂ Range | 0–20 vol.% |
| CO₂ Measurement Principle | Single-beam IR sensor |
| Recovery Time after 30-sec Door Opening (min @37°C) | 5 / 6 / 6 |
| Rated Power (230 V, kW) | 0.8 / 1.4 / 1.5 |
| Standard/Max Shelf Quantity | 2/3 / 3/6 / 3/8 |
| Brand | InterScience |
|---|---|
| Origin | France |
| Model | Scan 5000 Ai |
| Camera | 69 MP Ultra-HD CMOS Color Sensor with Japanese HD Zoom Lens |
| Illumination | Auto-Configurable 7-Mode LED Dome Lighting (Top/Bottom, White/Black Background) |
| Petri Dish Compatibility | Ø 55–150 mm circular & 120 mm square dishes |
| Colony Detection Limit | ≥ 0.03 mm diameter |
| Counting Speed | Up to 1000 colonies/sec |
| Zone Measurement Accuracy | ±0.1 mm |
| Zone Detection Time | 2–4 sec for up to 16 antibiotics |
| Standards Compliance | ISO 7218, AOAC 977.27, CLSI, EUCAST, CA-SFM (Human & Veterinary), FDA 21 CFR Part 11 |
| Software Languages | English, French, German, Spanish, Japanese, Chinese, Russian |
| Data Export Formats | CSV, Excel™, PDF, JPEG, PNG, BMP, SCA, BIO |
| System Requirements | Windows 10/11, Intel i7 (2.8 GHz+) or Xeon Gold, NVIDIA RTX 3060/4050+, 16 GB RAM, USB 3.0, 1920×1080+ display |
| Dimensions (W×D×H) | 46.4 × 46.4 × 63.1 cm |
| Net Weight | 25.15 kg |
| Warranty | 3 years (registration required) |
| Spare Parts Availability | 10 years |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | DM750M |
| Instrument Type | Upright Microscope |
| Illumination | White LED (Transmitted & Reflected Light) |
| Magnification Range | 50×–1000× |
| Objective Turret | 4-position or 5-position |
| Condenser | Adjustable Abbe condenser for transmitted light |
| Reflected Light Module | LED-based with field diaphragm and aperture diaphragm |
| Stage | Mechanical XY stage with 25–30 mm specimen clamp compatibility |
| Eyepieces | 10× widefield (20 mm field number), optional ergonomic viewing tubes (four configurations) |
| Digital Imaging | Compatible with Leica ICC50 HD, DMC2900, and other Leica-certified CMOS/CCD cameras |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | MATRIX Orbital Delta F2.0 |
| Orbit Diameter | 3 mm |
| Max Load | 0.3 kg |
| Speed Range | 0–1500 rpm |
| Min Adjustable Speed | 300 rpm |
| Speed Accuracy | ±30 rpm |
| Speed Resolution | 10 rpm steps |
| Timer Range | 1 s – 6000 min |
| Heating Range | RT +4 °C to 100 °C |
| Heating Power | 100 W |
| Temp. Control Accuracy | ±0.5 °C |
| Temp. Uniformity | ±0.5 °C (20–45 °C), ±1.5 °C (>45 °C) |
| Heating Rate | 13 °C/min |
| Sample Capacity | 24 × 2.0 mL tubes |
| Dimensions (W×D×H) | 216 × 158 × 351 mm |
| Weight | 9.2 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Protection Class | IP21 |
| Interfaces | RS232, USB |
| Power Supply | 100–240 V, 50/60 Hz |
| Max Input Power | 240 W |
| Fuse | 2 × T4A 250V |
| Brand | Parvo Medics |
|---|---|
| Origin | USA |
| Model | True One2400 |
| O₂ Analysis Range | 0–100% or 0–25% |
| O₂ Accuracy | ±0.02% |
| O₂ Response Time | 200 ms (21% → 16% in 4 L mixing chamber) |
| CO₂ Analysis Method | NDIR (Non-Dispersive Infrared) |
| CO₂ Range | 0–15% |
| CO₂ Accuracy | ±0.03% (for 0–10% CO₂) |
| CO₂ Response Time | 100 ms |
| Flow Measurement Accuracy | ±0.5% |
| Flow Range | 0–800 L/min |
| Calibration | Dual-stage (3 L syringe, 16% O₂ / 4% CO₂ gas mixture) |
| Operating Temperature | 14–30 °C |
| Relative Humidity | 20–80% RH |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Software Platform | Windows XP–compatible proprietary metabolic analysis suite |
| Data Export | Native Excel (.xls) output |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | ScanStation |
| Camera Resolution | 5 MP |
| Petri Dish Capacity | 100 (90 mm) |
| Imaging Interval | Every 30 minutes |
| Temperature Range | 10–45 °C |
| Temperature Uniformity | ±1 °C at 9 internal points |
| Cooling/Heating Technology | Peltier modules (compressor-free, fluid-free) |
| Display | 23-inch capacitive touchscreen |
| Operating System | Windows 10 (integrated PC: Intel Core i7) |
| Data Export | Excel™ |
| Video Playback | Full time-lapse with zoom, pause, rewind |
| Dimensions (W × D × H) | 136 × 83 × 91 cm (arm attached) |
| Total Height (incl. storage cabinet) | 151 cm |
| Weight | 287 kg (unit), 59 kg (storage cabinet) |
| Power Supply | 100–240 V~, 50–60 Hz |
| Max Power Consumption | 2000 W |
| Environmental Limits | Ambient temperature 18–25 °C |
| Max Incubation Duration | 10 days |
| Compliance | CE, ISO 17025-ready architecture, GLP/GMP data integrity support (audit trail, user access control, electronic signatures via optional FDA 21 CFR Part 11 module) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | BD-S 56 / BD-S 115 |
| External Dimensions (W×H×D) | 560×580×515 mm / 740×790×555 mm |
| Internal Dimensions (W×H×D) | 400×400×350 mm / 550×550×390 mm |
| Internal Volume | 62 L / 118 L |
| Net Weight (empty) | 41 kg / 57 kg |
| Temperature Range | Ambient +5 °C to 70 °C |
| Temperature Uniformity (±K @ 37 °C) | 0.7 / 0.5 |
| Temperature Fluctuation (±K @ 37 °C) | 0.1 / 0.2 |
| Recovery Time (min @ 37 °C, 30 s door opening) | 15 / 15 |
| Power Consumption (Wh/h @ 37 °C) | 25 / 25 |
Show next