- All
- Favorite
- Popular
- Most rated
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | FWT |
| Voltage | 110 V or 240 V AC |
| Display | Integrated touchscreen interface |
| Load Cell Options | 5 kN, 13 kN, 22 kN, 45 kN |
| Operating Pressure Range | 80–150 PSI (5.5–10.3 bar) |
| Drop Heights | 1 m, 2 m, 3.35 m |
| Maximum Impact Energy | 1100 J |
| Maximum Impact Velocity | 8.1 m/s |
| Drop Mass Range | 1–35 kg |
| Safety System | Full electrical interlock with cabinet door sensing |
| Release Mechanism | Solenoid-actuated bracket release |
| Return System | Pneumatic carrier return |
| Guidance | Dual vertical precision rails with low-friction bearings |
| Rebound Arrest | Standard anti-rebound mechanism |
| Height Measurement | Digital height readout |
| Sample Chamber Clearance | Up to Ø400 mm (customizable for larger diameters) |
| Fixture Options | Adjustable vertical support fixture |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP-2000+ |
| Temperature Range (L-Series) | 5–75°C |
| Temperature Range (H-Series) | 50–235°C |
| Shear Rate Range | 10–13,300 s⁻¹ |
| Sample Volume | 24–1700 µL (depending on cone geometry) |
| Cone Angles | 1°, 2°, 4° (standard), custom options available |
| Torque Range | High-torque mode up to 2000+ dyne·cm |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Control Interface | Built-in touchscreen + PC via CAPCALC™ software |
| Cone/Plate Gap Adjustment | Motorized auto-gap calibration |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TMIX |
| Light Source | 880 nm NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Interval | 20 s |
| Compliance | Designed for GLP-compliant stability assessment |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | 30 °C – 1,100 °C |
| Sampling Rate | 10 data points/second |
| Atmosphere Control | Integrated Mass Flow Controller (MFC) for programmable gas switching |
| Buoyancy Correction | Automatic, model-based, no blank required |
| One-Click Method Launch | Yes |
| Optional Couplings | FTIR, MS, Micro GC, GC/MS |
| Sensor Output | Mass & Temperature |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | SP1820 (Metric) / SP1822 (Imperial) |
| Dimensions (Unit) | 140 × 170 × 340 mm |
| Weight (Unit) | 4150 g |
| Max Panel Size | 150 × 100 mm |
| Max Panel Thickness | 1 mm |
| Mandrel Set Count | 14 (SP1820) / 7 (SP1822) |
| Mandrel Diameters | 2–32 mm (SP1820) / 1/8–1 in (SP1822) |
| Base Frame Dimensions | 100 × 130 × 160 mm |
| Load Arm Mass (with mandrel) | 2900 g (SP1820) / 1740 g (SP1822) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito |
| Instrument Type | Portable Digital Density Meter |
| Sample Type | Solids and Liquids |
| Density Range | 0.000–3.000 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Operating Temperature Range | −10 °C to +50 °C |
| Measurement Units | g/cm³, g/mL, kg/m³, °Brix, API, °Baumé, % ethanol (v/v), % H₂SO₄, US/UK Proof, Plato, specific gravity, user-defined concentration scales |
| Data Storage Capacity | 1100 measurements with sample ID, temperature correction factor, instrument ID, timestamp, and unit |
| Display | Full-color backlit LCD |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, optional printer output, compatible with EasyDirect PC software |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | X250-1 / X250-2.5 / X250-3 |
| Load Capacity | 1 kN / 2.5 kN / 3 kN |
| Load Accuracy | ±0.5% of reading, down to 0.1% of sensor full scale |
| Effective Test Stroke | 630 mm / 990 mm / 990 mm |
| Vertical Clearance | 800 mm / 1160 mm / 1160 mm |
| Position Resolution | 1 µm |
| Throat Depth | 108 mm |
| Speed Range | 0.00001–2500 mm/min |
| Speed Accuracy | ±0.1% at steady state |
| Maximum Force at Full Speed | 1 kN / 2.5 kN / 3 kN |
| Data Acquisition Rate | 500 Hz (optional 1000 Hz) |
| Connectivity | Ethernet (USB via adapter optional) |
| Frame Stiffness | 8 kN/mm |
| Weight | 58 kg / 65 kg / 65 kg |
| Operating Temperature | −10 °C to +40 °C |
| Humidity | 10–90% RH (non-condensing) |
| Power Supply | 230 V, 1-phase, 50/60 Hz (115 V option available) |
| Power Consumption | 0.3 kW |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 Excellence Series |
| Temperature Range | −150 °C to 700 °C |
| Data Acquisition Rate | Up to 50 data points per second |
| Sensor Type | MultiSTARe™ DSC sensor with 56 or 120 thermocouple pairs (Au/Au-Pd) |
| Cooling Rate | 0.02 K/min to 50 K/min |
| Calibration | FlexCal® (fully automated, multi-point, reference-based) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Krüss |
|---|---|
| Origin | Germany |
| Model | DSA |
| Max Operating Temperature | 2000 °C |
| Atmosphere Options | Oxidizing, Reducing, Inert Gas, Vacuum |
| Measurement Principle | Optical Contact Angle Analysis via High-Resolution CCD Imaging |
| Sample Environment | Non-contact, Gravity-driven Droplet Shape Evolution under Controlled Thermal Ramp |
| Compliance | ASTM D1857 (Ash Fusibility), ISO 562 (Coal Ash Fusibility), GLP/GMP-ready Data Audit Trail |
| Brand | TQC Sheen |
|---|---|
| Country of Origin | Netherlands |
| Model | CurveX 4 |
| Dimensions | 110 × 85 × 35 mm |
| Weight | 190 g (6.7 oz) |
| Housing Material | Anodized Aluminum |
| Operating Temperature | 0–60 °C |
| Measurement Range | −200 to 1300 °C |
| Accuracy | ±1 °C (±1.8 °F) |
| Battery Life | Up to 35 h (rechargeable Li-ion via USB-C) |
| Data Storage | 20 batches, 50,000 readings total |
| Sampling Interval | 1 s to 60 min (user-programmable) |
| Channels | 8 thermocouple inputs (Type K standard) |
| Display | Triple-color LED status indicators |
| Interface | USB-C (data export & charging) |
| Compliance | Qualicoat, GSB, ISO 9001, QIB, and ASTM D3003-22 (for thermal profiling in coating cure validation) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF Series |
| Type | Benchtop Environmental Test Chamber |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–80 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.1–0.4 K |
| Humidity Stability (25 °C / 60 % RH) | ±1.5 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1–3 min |
| Power Consumption | 1.3–1.7 kW |
| Internal Volume | 127–1610 L |
| Refrigerant | R-600a |
| Compliance | DIN 12880, ICH Q1–Q5, GLP/GMP-ready |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | X350 |
| Load Capacity | 5 kN / 10 kN / 20 kN |
| Load Accuracy | ±0.5% of reading down to 0.1% of sensor full scale |
| Effective Test Stroke | 1100 mm |
| Vertical Clearance | 1275 mm |
| Position Resolution | 1 µm |
| Minimum Speed | 0.00001 mm/min |
| Maximum Speed | 2000 mm/min |
| Speed Accuracy | ±0.1% at full speed under steady-state conditions |
| Crosshead Stiffness | 50 kN/mm |
| Data Acquisition Rate | 500 Hz (optional 1000 Hz) |
| PC Interface | Ethernet (USB via adapter optional) |
| Frame Type | Dual-column, bench-mounted (floor cabinet optional) |
| Weight | 120 kg |
| Operating Temperature | −10 °C to +40 °C |
| Power Consumption | 0.45 kW |
| Overload Protection | Up to 800% of sensor capacity |
| Motor Type | Brushless AC servo motor with 4,000,000 steps/revolution positioning resolution |
| I/O Channels | 6 digital I/O for extensometers, micrometers, calipers, balances, etc. |
| Additional Features | Self-cleaning preloaded ball screws |
| Brand | KRÜSS |
|---|---|
| Origin | Germany |
| Model | BPT Mobile |
| Surface Tension Range | 10–100 mN/m |
| Resolution | 0.1 mN/m |
| Surface Age Range | 10–30,000 ms |
| Temperature Measurement Range | 0–100 °C |
| Display | 5-inch IPS touchscreen (480 × 854 px) |
| Battery Life | Up to 10 hours |
| Dimensions (W × D × H) | 85 × 55 × 220 mm |
| Weight (without accessories) | 600 g |
| Measurement Principle | Bubble Pressure Method |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PFT |
| Pricing | Available Upon Request |
| Axial Load Capacity | 7 kg |
| Load Accuracy | ±0.6% FSR |
| Plunger Speed | 0.1–5 mm/s |
| Displacement Accuracy | ±0.3 mm |
| Torque Range | ±7.0 N·m |
| Torque Accuracy | ±1.2% FSR |
| Hopper Rotation Speed | 1–5 RPH |
| Temperature Sensing Range | −20 °C to 120 °C |
| Humidity Sensing Range | 10–95% RH (±5% accuracy) |
| Test Modes | Flow Function, Time-Consolidated Flow Function, Wall Friction, Bulk Density |
| Flow Function Submodes | Demo (8 min), Standard (38 min), User-Defined Time Consolidation |
| Shear Algorithm Outputs | Peak Shear Stress, Steady-State Yield Locus, Stick-Slip Identification |
| Output Parameters | Flow Function Index (FF), Arching Diameter (Index), Rathole Diameter, Hopper Half-Angle, Gravity Chute Angle (Wall Friction Angle), Bulk Density Curve |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | PCP |
| Weight | 72 kg |
| Dimensions (W×D×H) | 300 × 300 × 630 mm |
| Operating Air Pressure | 10 bar (145 psi) |
| Maximum Punch Force | 50 kN |
| Compatible Die Shank Diameter | 25 mm (standard), custom shanks available |
| Cutting Plate Material | Polypropylene |
| Safety Guard | Polycarbonate interlocked shield |
| Base Footprint | 500 × 300 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy D30, Easy D40 |
| Instrument Type | Benchtop Digital Density Meter |
| Sample Type | Solid and Liquid |
| Density Range | 0–3 g/cm³ |
| Temperature Range | 15–25 °C (Easy D30), 15–50 °C (Easy D40) |
| Density Resolution | 0.001 g/cm³ (Easy D30), 0.0001 g/cm³ (Easy D40) |
| Density Accuracy | ±0.001 g/cm³ (Easy D30), ±0.0005 g/cm³ (Easy D40) |
| Temperature Accuracy | ±0.2 °C (Easy D30), ±0.1 °C (Easy D40) |
| Minimum Sample Volume | 1.2 mL |
| Measurement Units | Density, Specific Gravity, Alcohol % v/v, Brix, API Gravity, Acidity, Urea Concentration, Custom Concentration |
| Built-in Methods | 16 |
| Bubble Detection | BubbleCheck™ (Easy D40 only) |
| Viscosity Correction | Automatic (both models) |
| Cleaning Check | Yes (both models) |
| Dimensions (W × H × D) | 170 × 156 × 273 mm |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | X500 |
| Load Capacity | 25 kN / 30 kN / 50 kN / 100 kN |
| Load Accuracy | ±0.5% of reading, down to 0.1% of sensor capacity |
| Effective Test Stroke | 1025 mm / 1025 mm / 950 mm / 1100 mm |
| Vertical Clearance | 1225 mm / 1225 mm / 1150 mm / 1300 mm |
| Position Resolution | 1 µm |
| Minimum Speed | 0.00001 mm/min |
| Maximum Speed | 1000 mm/min / 1000 mm/min / 1000 mm/min / 500 mm/min |
| Speed Accuracy | ±0.1% at full speed under steady-state conditions |
| Crosshead Stiffness | 120 kN/mm / 120 kN/mm / 220 kN/mm / 400 kN/mm |
| Data Acquisition Rate | 500 Hz (optional 1000 Hz) |
| Connectivity | Ethernet (USB via adapter optional) |
| Frame Type | Dual-column, benchtop-mountable (floor cabinet optional) |
| Weight | 155 kg / 155 kg / 195 kg / 235 kg |
| Operating Temperature | 10–90 °C |
| Power Requirement | 1 kW |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / DensitoPro |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Sample Temperature Range | 0–50 °C |
| Ambient Temperature Range | Densito: −10–50 °C |
| DensitoPro | 0–50 °C |
| Data Storage Capacity | 1,100 results |
| Supported Units | Density, Specific Gravity, Brix, API Gravity, Baumé, Ethanol (% v/v), H₂SO₄ Concentration, US/UK Proof, Plato, User-Defined Concentrations |
| Display | Full-color backlit LCD |
| Languages | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, Bluetooth (DensitoPro), RFID/Barcode Reader (DensitoPro only) |
| Software Integration | EasyDirect PC Software |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready data export |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVPlus |
| Display | 5-inch full-color touchscreen |
| Speed Control | 740 programmable RPM increments (0.1–200 rpm) |
| Viscosity Range | 1 cP to 320,000,000 cP (depending on spindle and speed selection) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Torque Measurement | 0.1–100% of full-scale torque (mN·m, dyne·cm, %) |
| Temperature Compensation | ±5°C |
| Interface | USB + Bluetooth (DVPlus CONNECT compatible) |
| Optional Accessory | RTD temperature probe (DVP-94Y) |
| Language Support | English, French, German, Portuguese, Spanish, Japanese, Chinese |
| Compliance | Designed for GLP/GMP environments |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF PRO |
| Temperature Range | −20 to 100 °C |
| Humidity Range | 10–98 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.2 K (KBF PRO 130 & 260), ±0.3 K (KBF PRO 470–1600) |
| Temp. Stability (25 °C / 60 % RH) | ±0.1 K |
| Humidity Stability (25 °C / 60 % RH) | ±1 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1 min |
| Recovery Time (40 °C / 75 % RH, 30 s door open) | 3–5 min |
| Internal Volume | 127–1610 L |
| Power Consumption | 1.6–1.9 kW |
| Refrigerant | R-290 (eco-friendly hydrocarbon) |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 3 PRO |
| Dry Sieving Range | 32 µm – 63 mm |
| Wet Sieving Range | 20 µm – 10 mm |
| Micro Sieving Range | 5 µm – 100 µm |
| Sample Capacity (Dry) | <100 g (for <100 µm), <1 kg (for <25 mm) |
| Sample Capacity (Wet) | 20–100 g |
| Sample Capacity (Micro) | 0.2–0.5 g |
| Sieving Time (Dry) | 3–20 min |
| Sieving Time (Wet) | 3–10 min |
| Sieving Time (Micro) | 30–60 min |
| Max. Stackable Sieve Trays | 10 × 50 mm trays or 16 × 25 mm trays |
| Compliance | ISO 3310-1/-2, ASTM E11, DIN 66165, EN 10204 3.1B |
| Software Interface | AUTOSIEVE (PC-connected, GLP-compliant data logging) |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 18 |
| Voltage | 230 V, 1~ |
| Frequency | 50–60 Hz |
| Input Power | 480 W |
| Sieving Method | Dry Sieving |
| Sample Condition | Dry |
| Sieving Range (Dry) | 20 µm – 125 mm |
| Max. Sample Load | 6 kg |
| Sieving Time | 5–60 min |
| Dimensions (W×L×H) | 58 × 58 × 39 cm |
| Net Weight | 92 kg |
| Gross Weight | 129 kg |
| Motor Type | Two maintenance-free asymmetric motors |
| Motion Type | Simultaneous horizontal and vertical oscillation |
| Compliance | ISO 3310-1, ASTM E11-95, ISO 9000 traceable calibration |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | CAT |
| Stroke Length | 12.7–50.8 mm (0.5–2 in) |
| Frequency Range | 0–2.5 Hz |
| Top Cylinder Pressure | 0–6 bar (0–87 psi) |
| Side Cylinder Pressure | 0–6 bar (0–87 psi) |
| Compatible Can Volume | 150–1000 mL |
| Minimum/Maximum Can Diameter | 53–84 mm |
| Minimum/Maximum Can Height | 88–205 mm |
| Operating Temperature | 0–50 °C (32–122 °F) |
| Operating Humidity | 0–90 % RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Air Supply | 8 bar ±20 % |
| Sound Level | <70 dB(A) |
| Weight | 125 kg (276 lb) |
| Dimensions | 1050 × 790 × 760 mm (41.3 × 31.1 × 29.9 in) |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | Powder Coating Thickness Gauge |
| Measurement Range | 0–300 µm |
| Accuracy | ±3% of reading |
| Resolution | ±1% of reading |
| Standoff Distance | ~35 mm |
| Spot Size | 2 × 2 mm |
| Measurement Speed | 1024–2048 measurements/sec |
| Dimensions | 80 × 180 × 43 mm |
| Weight | 700 g |
| Interface | USB |
| Power Supply | 4 × AA Li-ion batteries (3.7 V each), up to 10 hours continuous operation |
| Substrate Compatibility | Ferrous & non-ferrous metals (e.g., steel, aluminum), MDF |
| Operating Humidity | ≤80% RH at 32°C |
| Storage Temperature | 0–55°C |
Show next