| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS Precision Balance |
| Instrument Type | Precision Balance |
| Maximum Capacity | ≥5000 g |
| Readability | 1 mg (0.001 g) to 1 g |
| Sensor Technology | MonoBloc® single-module weighing cell |
| Repeatability (sd) | 0.001–0.5 mg (model-dependent) |
| Linearity Error | 0.002–0.3 mg (model-dependent) |
| Pan Dimensions | 127×127 mm to 351×245 mm |
| Calibration | FACT™ automatic internal calibration or external calibration (models ending in “E”) |
| Connectivity | RS232 and USB interfaces |
| Display | High-Contrast Display (HCD) |
| Leveling | Front-access leveling feet with integrated bubble level indicator |
| Draft Shield | QuickLock™ removable glass draft shield (dishwasher-safe for 0.001 g models) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XP Micro Balance |
| Readability | down to 0.001 mg |
| Repeatability (sd) | as low as 0.002 mg |
| Linearity error | ≤ 0.006 mg |
| Typical stabilization time | 3.5 s |
| Pan dimensions | 40 × 40 mm |
| Compliance | GWP® Excellence, USP <41>/<1251>, ISO/IEC 17025, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Analytical Balance |
| Model Range | XSR105, XSR105DU, XSR205DU, XSR64, XSR104, XSR204, XSR204DR, XSR304, XSR225DU |
| Maximum Capacity | 61–320 g (full range) |
| Readability | 0.01 mg (high-resolution models) to 1 mg |
| Repeatability (sd, 5% load) | 0.008–0.04 mg |
| Stabilization Time | 1.5–3 s |
| Minimum Weight (USP <41> compliant) | 16–82 mg |
| Calibration | proFACT — fully automatic, time- and temperature-triggered internal calibration |
| Display | Full-color touchscreen with multilingual UI (including English) |
| Connectivity | 4 × USB ports, 1 × Ethernet (LAN) port |
| Environmental Control | Active Temperature Control (ATC™), LevelControl™ leveling system, SmartGrid™ draft shield grid |
| Compliance | USP <41>, GWP® Verified, GLP/GMP-ready audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Precision Balance |
| Model Series | XS |
| Sensor Technology | MonoBloc HighSpeed single-module electromagnetic force compensation sensor |
| Readability | 0.1 mg to 1 g |
| Max Capacity | 210 g to 100 kg |
| Repeatability (sd) | 0.0008 mg to 0.6 g |
| Linearity Error | 0.002 mg to 0.3 g |
| Stabilization Time | 1.2 s to 1.5 s |
| Pan Dimensions (W×D) | 127×127 mm to 280×360 mm |
| Protection Class | IP54 |
| Construction | Full-metal monocoque frame with rounded edges and seamless, flat surfaces |
| Interface Options | RS232 (standard), plus modular slot for Bluetooth, Ethernet, PS/2, LocalCAN, or MiniMettler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MR Series (MR104, MR204, MR304) |
| Maximum Capacity | 120 g / 220 g / 320 g |
| Readability | 0.1 mg |
| Repeatability (5% load) | 0.08 mg (typical) |
| Linearity Error | 0.06 mg (typical) |
| Sensitivity Shift (nominal load) | 0.3–0.6 mg |
| Minimum Weight (USP <1251>, ±0.10% tolerance) | 60–160 mg |
| Stabilization Time | 2 s |
| Pan Diameter | 90 mm |
| Dimensions (W × D × H) | 209 × 351 × 354 mm |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Calibration | FACT® Automatic Internal Calibration |
| Certifications | OIML R76, NTEP Class I |
| Interfaces | USB-A, USB-C, RS232, Ethernet |
| Software Compatibility | MT-SICS, EasyDirect™ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Micro Balance |
| Readability | 0.001 mg / 0.01 mg (dual range) |
| Max Capacity | 0.8 g / 3.1 g (dual range) |
| Repeatability (sd) | 0.0008 mg / 0.006 mg |
| Linearity Error | ±0.01 mg |
| Typical Stabilization Time | 6 s |
| Pan Diameter | Ø27 mm |
| Design | Separated weighing unit and display/control unit |
| Built-in Applications | Weighing, Statistics, Formulation, Counting, Percentage, Density, Dynamic Weighing |
| Compliance | GWP® Excellence integrated risk-based validation support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | ME Series |
| Instrument Type | Analytical Balance / Precision Balance |
| Maximum Capacity | 20–100 g (model-dependent) |
| Readability | 0.0001 g (0.1 mg) to 0.1 g (model-dependent) |
| Repeatability | ≤ 0.0001 g (for 0.1 mg models) |
| Linearity Error | ≤ 0.0002 g (for 0.1 mg models) |
| Pan Dimensions | 90 mm to 180 × 180 mm (model-dependent) |
| Calibration | Internal automatic calibration (integrated motor-driven mass) |
| Compliance | ISO/IEC 17025, GLP, GMP, USP <41>, ASTM E898, FDA 21 CFR Part 11 (with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS Semi-Micro Balance |
| Readability | 0.01 mg (10 µg) |
| Max Capacity | up to 220 g (dual-range models) |
| Repeatability (sd) | as low as 0.02 mg |
| Linearity Error | ≤ 0.2 mg |
| Pan Diameter | Ø80 mm |
| Calibration Technology | FACT (Fully Automatic Calibration Technology) with internal dual-weight system |
| Display | High-Contrast Display (HCD) |
| Draft Shield | QuickLock modular glass draft shield with ErgoDoor left/right reversible door mechanism |
| Connectivity | RS232 and USB interfaces |
| Built-in Applications | Weighing, Statistics, Piece Counting, Percentage Weighing, Density Determination, Dynamic Weighing, Checkweighing, Value Recall |
| Compliance | Designed and manufactured in accordance with ISO 9001, ISO/IEC 17025, and GLP/GMP documentation requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MR Precision |
| Maximum Capacity | 100 g – 6.2 kg |
| Readability | 1 mg – 100 mg |
| Repeatability (5% load) | 0.7 mg – 7 mg (typical) |
| Linearity | 0.6 mg – 6 mg (typical) |
| Sensitivity Shift (nominal load) | 5 mg – 150 mg |
| Minimum Weight (USP, ±0.10%) | 1.4 g – 100 g |
| Stabilization Time | 1.0 – 1.5 s |
| Pan Diameter | 120 mm or 180 × 180 mm |
| Dimensions (W × D × H) | 209 × 351 × 354 mm or 209 × 351 × 100 mm |
| Interfaces | USB-A, USB-C, RS232, Ethernet |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSR Precision Balance |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Readability | Down to 0.1 mg–1 mg (model-dependent) |
| Repeatability | ≤ 0.0002 g (at full capacity) |
| Internal Calibration | FACT (Fully Automatic Calibration Technology) with motorized weights |
| Environmental Compensation | Built-in temperature and drift monitoring |
| Connectivity | 4× USB-A, 1× Ethernet (LAN), optional RS-232 |
| Data Security | User-level password protection, audit trail enabled, 21 CFR Part 11 compliant configuration available |
| SmartPan™ | Patented draft shield-free weighing pan design reducing air current interference |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | BBA238 |
| Protection Rating (Indicator) | IP66/IP67 |
| Protection Rating (Weighing Platform & Load Cell) | IP68/IP69K |
| Display | 7-segment LCD, 60 mm digit height, white adjustable backlight |
| Stabilization Time | <1 s |
| Accuracy Class | III |
| Power Supply | 85–264 VAC, 50/60 Hz |
| Optional Rechargeable Battery | NiMH, >80 h runtime |
| Weighing Units | kg, lb, g, oz |
| Interface | RS232 |
| Construction | AISI 304 stainless steel (housing, platform frame, pan, and column) |
| Load Cell | Hermetically welded stainless steel |
| Overload Protection | Mechanical limit stop |
| Functions | Weighing, Checkweighing, Counting (with average piece weight optimization), Accumulation, Animal Weighing, Date/Time (RTC), x10 scaling, Unit Switching, Target Storage, Print |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR26/56 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.0003 mg |
| Calibration | Automatic (proFACT) |
| Compliance | USP Chapter <41> & <1251>, ISO/IEC 17025, GWP® Verified |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ICS689 |
| Protection Rating | IP68/IP69K |
| Construction | Full AISI 304 Stainless Steel (1.4301) |
| Display | Color TFT (320×240 px), 3-line mode, 17 mm character height |
| Weighing Functions | Checkweighing, Counting, Filling, Accumulation, Statistics, Label Printing, Multi-language UI (EN/DE/FR/IT/ES/PT/ZH/JP) |
| Connectivity | Standard RS232 + Scale Interface (analog/IDNet/SICSpro) |
| Optional | Ethernet, WLAN, USB Host/Device, Digital I/O (4 in/4 out), RS422/485 |
| Sensor Support | Up to 4 load cells (strain gauge type), compatible with F-cell, AWU, GD16-17, PIK excluded |
| Internal Alibi Memory | 300,000 transactions |
| Calibration Log | Embedded |
| Certifications | OIML R76, NTEP Class III, CE, CSA C/US, GMP-compliant, EHEDG Certified, NSF/ANSI 2, CMC |
| Operating Temperature | –10 °C to +40 °C (Class III), Humidity: ≤85% RH at 40 °C |
| Power | 100–240 VAC, 50–60 Hz, 300 mA |
| Optional Battery | 12 VDC/2.5 A — 22 h (1 sensor), 18 h (4 sensors) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS-TS |
| Type | Precision Balance |
| Capacity | ≥5000 g |
| Readability | 0.001 g |
| Display | 7-inch full-color TFT touchscreen |
| Character height | 18 mm |
| Leveling system | 3 fixed feet + 2 locking leveling feet |
| Calibration | FACT fully automatic internal calibration |
| Sensor technology | MonoBloc single-module weighing cell |
| MinWeigh function | visual red alert when sample mass falls below user-defined minimum weighing value |
| Sample ID tracking | up to 4 identifiers per weighing (e.g., operator, sample ID, batch, date) |
| LevelControl | real-time tilt detection with on-screen leveling guidance |
| Overload protection | built-in mechanical and electronic protection |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML Series (ML54 / MS104 / MS204) |
| Maximum Capacity | 52 g / 120 g / 220 g |
| Readability | 0.1 mg |
| Repeatability (sd) | 0.1 mg |
| Linearity Error | 0.2 mg |
| Pan Diameter | Ø90 mm |
| Calibration | Internal |
| Power Supply | AC adapter or 8×AA batteries (up to 8 h operation) |
| Connectivity | RS232 and USB |
| Compliance | GxP-ready with audit trail-capable printing (when used with RS-P26 printer) |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | SP1560 |
| Measurement Range | 0–3.4 mm (0–0.13 in) |
| Accuracy | ±5 µm (±0.2 mil) |
| Repeatability | 1 µm (±0.04 mil) |
| Probe Thread | M2.5 × 0.45 |
| Probe Shank Diameter | 8 mm (0.3 in) |
| Dual-Function Capability | Surface Roughness + Coating Thickness |
| Compliance | ASTM D4417, ISO 2808 |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | TAC7 |
| Sample Area | 300 mm × 220 mm |
| Max Sample Height | 30 mm |
| Single-Point Measurement Diameter | 120 mm |
| Depth of Field | ±3 mm |
| Color Capture Angles | 5°, 22.5°, 45°, and 67.5° (four monochrome cameras) |
| Spatial Resolution | Up to 385 dpi at 5° camera (66 µm/pixel) |
| Illumination | 32 white LEDs, linear light scanner for near-specular illumination, three spectral wheels, backlight unit for alpha mapping |
| Software Integration | Pantora Material Hub, AxF™ (Appearance Exchange Format) compliant |
| Security Compliance | Enterprise-grade IT infrastructure compatible (TLS 1.2+, AES-256 encryption, LDAP/AD integration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML-T |
| Instrument Type | Precision Balance |
| Capacity | ≥ 5000 g |
| Readability | 0.001 g (1 mg) |
| Display | 4.5-inch color TFT touchscreen |
| Weighing Technology | MonoBloc single-module electromagnetic force compensation sensor |
| Calibration | FACT — Fully Automatic Calibration Technology with internal temperature-controlled reference mass |
| Leveling | LevelControl integrated tilt sensor with visual guidance |
| Connectivity | USB Device, USB Host, RS232, optional Bluetooth |
| Data Output | PC Direct mode (no driver or software required) |
| Compliance | ISO/IEC 17025, GLP/GMP traceability support, FDA 21 CFR Part 11 ready (with optional software and user management) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Analytical Balance |
| Maximum Capacity | 100 g |
| Readability | 0.01 mg (10 µg) |
| Repeatability | < ±1 mg |
| Calibration | Fully Automatic (proFACT) |
| Compliance | USP Chapter 41 & 1251, ISO/IEC 17025, GLP/GMP-ready |
| Display | Capacitive Color Touchscreen with StatusLight™ |
| Connectivity | 4× USB, 1× Ethernet (LAN) |
| Environmental Control | Active Temperature Control (ATC™), StaticDetect™ + optional ionizer, SmartGrid draft shield, LevelControl™ leveling system |
| Software Features | Built-in method storage, result notebook, MinWeigh™ warning, user permission management (multi-level), audit trail, GWP® Verification support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Seven2Go (S2, S3, S4, SG23, S7, S8, S9) and SevenGo Duo (SG68, SG78, SG98) |
| Measurement Parameters | pH / mV / Ion Concentration / Conductivity / TDS / Resistivity / Salinity / Dissolved Oxygen / Atmospheric Pressure / Temperature |
| Temperature Compensation Modes | Linear, Non-linear, Pure Water |
| Calibration Points | up to 5 (pH), up to 25 (Conductivity), up to 5 (Dissolved Oxygen) |
| Buffer/Standard Sets | 4 (pH), 3 (Conductivity), 4 (Dissolved Oxygen), 138–666 µS/cm custom ranges |
| Electrode Constant Input | Manual or Automatic (via ISM) |
| Endpoint Detection | Auto or Manual |
| Interval Measurement | Configurable |
| Display | Backlit LCD |
| Connectivity | Infrared (IR), micro-USB |
| Data Storage | 200–2000 GLP-compliant records (model-dependent) |
| Protection Rating | IP67 |
| Power Supply | 4× AA alkaline or NiMH batteries |
| Language Support | Up to 12 languages |
| Compliance | GLP, ISO/IEC 17025-aligned data integrity, FDA 21 CFR Part 11-ready (with optional software and audit trail configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | BBA211 |
| Display | 6-digit LCD with 25 mm white backlighted digits |
| IP Rating | IP65 (indicator and load cell assembly) |
| Legal-for-Trade Classification | OIML R76 Class III, 3000e |
| Non-legal resolution | 6000d |
| Internal resolution | 1/100,000 |
| Load cell material | Aluminum |
| Platform material | Powder-coated carbon steel |
| Pan material | Stainless steel (AISI 304 equivalent, grade 21CT) |
| Column material | Powder-coated carbon steel |
| Power supply | 9 V AC/DC adapter |
| Battery options | Three D-cell alkaline batteries (≈450 h continuous operation) or rechargeable sealed lead-acid battery (≈200 h) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MX Series (MX105, MX105DU, MX205DU, MX104, MX204, MX304) |
| Maximum Capacity | 120 g / 220 g / 320 g |
| Readability | 0.01 mg to 0.1 mg |
| Repeatability (at 5% load) | 0.0125–0.1 mg |
| Linearity | 0.06–0.3 mg |
| Stabilization Time | 2 s |
| Pan Diameter | 80–90 mm |
| Dimensions (W × D × H) | 222 × 379 × 353 mm |
| Certifications | OIML R76, NTEP Class I, USP <41> & <1251> compliant |
| Interface Options | USB-A, USB-C, Ethernet, Bluetooth (optional) |
| Software | MT-SICS, EasyDirect™ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR Automatic Dispensing Balance |
| Maximum Capacity | >5000 g |
| Readability | 2 µg |
| Accuracy Class | Class I (ISO 9001, ISO/IEC 17025 compliant) |
| Compliance | FDA 21 CFR Part 11 ready (with LabX), GLP/GMP traceable workflows |
| Software Integration | LabX® PC software (centralized instrument & user management, audit trail, electronic signatures) |
| Sample Handling | Integrated force compensation sensor, auto-tare on ultra-low-mass containers (down to 0.1 g tare), closed-loop dispensing control |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR Precision Balance |
| Instrument Type | Precision Balance |
| Maximum Capacity | 64.1 kg |
| Readability | 0.01 g (down to 0.1 mg in micro-precision variants) |
| Repeatability | 10 mg (up to 400 mg depending on model) |
| Stabilization Time | as fast as 0.8 s |
| Minimum Weight (USP <41>) | 82 mg – 820 g (model-dependent) |
| Compliance | USP <41>, ISO/IEC 17025, GLP/GMP-ready |
| Calibration | proFACT automatic time- and temperature-triggered internal calibration |
| Pan Technology | SmartPan™ Pro draft-free weighing pan (standard on most models) |
| Connectivity | 4 × USB-A, 1 × Ethernet (LAN), optional RS232 |
| Software Integration | LabX-compatible, FDA 21 CFR Part 11 compliant audit trail support via LabX |
| User Management | Multi-level role-based access control with customizable permissions |
Show next