Empowering Scientific Discovery

Dongnan Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelLH15/12–LF120/14
Max. Temperature1200–1400 °C
Chamber Dimensions (W×D×H)250×250×250 mm to 500×500×500 mm
Chamber Volume15–216 L
External Dimensions (W×D×H)680×860×1170 mm to 990×1280×1530 mm
Power Supply3-phase, 5.0–26.0 kW
Weight150–470 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuber
OriginGermany
ModelCC-K6, CC-K6s, KISS K6, KISS K6s
Temperature Range–25 °C to +200 °C
Heating Power1.6–2.1 kW
Cooling Power (at 20 °C)0.72 kW (CC-K6), 0.25 kW (KISS K6), 0.40 kW (CC-K6s), 0.26 kW (KISS K6s)
Bath Volume4.5 L
Bath Opening Dimensions140 × 120 mm
Bath Depth150 mm
Pump Flow Rate (Pressure/Suction)up to 27 L/min @ 0.4 bar / 22 L/min @ 0.15 bar (CC-K6)
External Circulation InterfaceYes
Temperature Stability±0.02 K (CC series), ±0.05 K (KISS series)
RefrigerantNatural (R744 / CO₂ or R290 / propane, per model configuration)
Safety ClassDIN 12876 Class III / FL (flammable liquid compatible)
ControllerPilot ONE with 7″ capacitive touchscreen, 11-language UI, RS232 interface, Pt100 sensor input, 2-point calibration, calendar-based scheduling, overtemperature & low-level protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelED-S Solid.Line
Instrument TypeStandard Drying Oven
Temperature RangeAmbient +7 °C to 250 °C
Temperature Uniformity±0.8 °C
External Dimensions (W×H×D)614 × 625 × 577 mm
Internal Dimensions (W×H×D)400 × 440 × 350 mm
Internal Volume62 L
Chamber MaterialStainless Steel (AISI 304)
Heating TechnologyAPT.line™ Preheating Chamber Technology
Air CirculationNatural Convection (Free Convection)
SafetyIndependent Adjustable Temperature Safety Device, Class 2 (DIN 12880), Optical Alarm
ControllerTime-Programmable Digital Controller
Accessories2 Chrome-Plated Wire Shelving Inserts
Exhaust ValveAdjustable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA
OriginJapan
ModelPSL
Temperature Range–40 °C to 0 °C / –80 °C to 0 °C / –80 °C to 20 °C
Temperature Stability±0.5 °C (PSL-1400) / ±1.0 °C (PSL-1810, PSL-2000)
Stirring Speed100–800 rpm
Heating Power250 W / 450 W / 750 W
Cooling CapacityAir-Cooled Compressor System (R404A, R507A/R23 Dual-Circuit)
Tank MaterialSUS304 Stainless Steel
Capacity2.1 L / 3.5 L / 8 L
Stirring Motor Output15 W / 25 W / 25 W
Safety FeaturesLeakage Current Protection, Overcurrent Protection, Overheating Prevention, Compressor High-Pressure Cut-off, Sensor Open-Circuit Detection, Self-Diagnostic Function (Heater Fault, Sensor Anomaly, Temp Deviation Alert), Compressor Delay Start
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelLHT/LB
Max. Temperature1650 °C
Chamber Dimensions (Ø × H)Ø185 × 185 mm (LHT 02/17 LB) / Ø260 × 260 mm (LHT 16/17 LB)
Chamber Volume2 L / 16 L
External Dimensions (W × D × H)390 × 590 × 765 mm / 650 × 1250 × 1980 mm
Power Supply3.4 kW (1-phase) / 12.0 kW (3-phase)
Weight50 kg / 410 kg
Heating ElementMolybdenum Disilicide (MoSi₂)
Temperature Uniformity≤ ±5 °C (at 1600 °C, steady state)
Control SystemSCR-controlled S-type thermocouple with overtemperature protection per EN 60519-2 Class 2
OptionalProtective Gas Inlet, Manual/Automatic Gas Supply, Adjustable Bottom Air Intake, Stackable Crucible Supports, Controltherm MV Process Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelR Series
Max Operating Temperature1200 °C or 1300 °C
Tube ID50–120 mm
Heating Zone Length250–1000 mm
External Dimensions (W×D×H)up to 1300 mm × 1170 mm × 460 mm
Power Supply1-phase (1.6–2.3 kW) or 3-phase (6.5–11.5 kW)
Weight22–89 kg
Control SystemHiProSystem (3-zone for models ≥750 mm heating length, 1300 °C), integrated S-type thermocouple, overtemperature protection per EN 60519-2 Class 2
Atmosphere Optionsinert gas, vacuum-compatible configurations available
Software IntegrationControltherm MV for process monitoring, logging, and compliance-ready data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelRT
Max. Operating Temperature1100 °C / 1300 °C / 1500 °C
Tube Diameter (Ø)50–150 mm
Heating Zone Length250–360 mm
Uniformity (ΔT @ 10 K)±5 K over heating zone
Power Supply1-phase, 1.8 kW
Weight25–45 kg
Construction MaterialC 530 high-alumina refractory tube
Thermocouple TypeS-type (detachable from support)
Mounting FlexibilityAdjustable height & tilt angle (horizontal, vertical, or inclined operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelED/FD Series
Heating PrincipleNatural Convection (ED) / Forced Air Convection (FD)
Temperature RangeAmbient +5 °C to 300 °C
Control SystemMicroprocessor-based with LED Display & Integrated Timer (0–99 h 59 min or continuous)
Safety ClassDIN 12880 Compliant, Dual-Level Thermal Protection (TWB)
Chamber MaterialsHigh-Performance Stainless Steel (AISI 304), Electrogalvanized Steel Enclosure with Corrosion-Resistant Coating
Chamber Volumes23 L, 53 L, 115 L, 240 L, 400 L, 720 L
InterfaceRS422 for APT-COM Data Management Software (Optional)
Interior DesignRounded Corners, Smooth Welded Surfaces, Removable Shelving, Tempered Glass Inner Door
InsulationAdvanced Low-Conductivity Mineral Wool
Surface FinishAnti-Dust Powder Coating
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuber
OriginGermany
Model RangeCC-208B, CC-212B, CC-215B, CC-220B, CC-225B, KISS 208B, KISS 212B, KISS 215B, KISS 220B, KISS 225B
Temperature Range−30 °C to +200 °C
Heating Power1.5–2.1 kW
Bath Volume7.5–23.5 L
Bath Depth150–200 mm
Opening Dimensions (W×D)230×127 mm to 290×329 mm
Temperature Stability±0.02 K (CC series), ±0.05 K (KISS series)
Pressure Pump Flow Rate27 L/min @ 0.72 bar (CC), 14 L/min @ 0.25 bar (KISS)
Suction Pump Flow Rate10.5 L/min @ 0.7 bar (CC & KISS)
External Dimensions (W×D×H)290×350×375 mm to 350×555×425 mm
ConstructionAISI 304 stainless steel bath tank
Cooling RequirementExternal chiller required for operation below ambient or at sustained low temperatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuber
OriginGermany
ModelMinichillers®
Temperature Range−5 °C to +40 °C (up to +80 °C return fluid temperature)
Refrigeration Capacity0.25–1.2 kW @ specified setpoints
Pump Flow Rate10–18 L/min
Max. Pressure0.3–0.9 bar
Dimensions (W×D×H)225×360×380 mm to 280×511×424 mm
ConstructionStainless steel housing
RefrigerantNatural R744 (CO₂) or R290 (propane), per model
OptionalIntegrated 1 kW heater (extends range to +100 °C)
InterfacesRS232, USB
DisplayOLED touchscreen (OLÉ controller)
ComplianceCE, RoHS, EN 61000-6-3/6-4, EN 61000-3-2/3-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuber
OriginGermany
ModelDC®
Temperature Range–30 °C to +50 °C
Refrigeration Capacity2.0–4.7 kW (at –20 °C)
Dimensions (W×D×H)190×250×360 mm (DC30) / 250×310×415 mm (DC31) / 280×340×465 mm (DC32)
RefrigerantR-410A
Power Supply230 V, 50/60 Hz
IP RatingIP20
Weight22–48 kg (model-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelRHTH
Temperature RangeUp to 1600 °C, 1700 °C or 1800 °C
ConfigurationHorizontal
Heating Zone Length150–600 mm
Uniformity (ΔT ≤ 10 K)Over Specified Zone
Tube Diameter50–120 mm
Power Supply3-phase, 400 V
Total Power5.4–14.4 kW
Net Weight70–110 kg
InsulationVacuum-formed Ceramic Fiber Boards (Low Thermal Mass)
Heating ElementSuspended MoSi₂
Thermocouple TypeType B (PtRh30/PtRh6)
ComplianceEN 60519-2 (Temperature Protection Class II)
Control CabinetSeparate Vertical Enclosure with SCR Power Controller & Low-Voltage Transformer
Optional FeaturesGas/Vacuum Sealing Flanges, Multi-Zone Temperature Control (3–4 Zones), Work-Tube Internal Thermocouple Monitoring, Backflow Prevention Check Valve, Vertical Mounting Kit (RHTV variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
ModelTC-150
Temperature Range (MX)Ambient +10°C to 135°C
Temperature Range (SD/AP)Ambient +10°C to 150°C
Temperature Stability (MX)±0.07°C
Temperature Stability (SD)±0.04°C
Temperature Stability (AP)±0.01°C
Controller OptionsMX (basic digital), SD (dual-speed pump, PC-controllable via Rheocalc), AP (touchscreen, programmable, multi-language UI, variable-speed pump)
Pump TypeSingle-speed (MX), Dual-speed (SD), Variable-speed (AP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelHTCT01/14, HTCT08/16
Max Temperature1400 °C / 1500 °C / 1600 °C
Chamber Dimensions (W×D×H)110×120×120 mm to 170×290×170 mm
Chamber Volume1.5 L to 8.0 L
External Dimensions (W×D×H)340×300×460 mm to 450×620×570 mm
Power Supply1-phase or 3-phase
Rated Power3.5 kW to 13.0 kW
Weight18 kg to 60 kg
Heating ElementSilicon Carbide (SiC) rods
ConstructionDouble-walled stainless steel housing with fiber insulation
Door TypeTop-opening (HTCT series) or front-opening (HTC series)
ComplianceEN 60519-2 (thermal protection class 2), optional overtemperature limiter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelFD56 / FD115 / FD260 / FD720
Temperature RangeAmbient +10 °C to 300 °C
External Dimensions (W×H×D, mm)1165×1590×870
Internal Dimensions (W×H×D, mm)1000×1300×570
Heating MethodForced-air circulation (APT.line™ preheating chamber technology)
Internal Volume60–741 L
Max. Load Capacity70–315 kg
Shelf Load Capacity30–45 kg per shelf
Temp. Uniformity at 150 °C±0.3–±2.5 K
Temp. Stability at 150 °C±0.3–±0.6 K
Heating Time to 150 °C15–25 min
Recovery Time after Door Opening (150 °C)4–6 min
Power Rating (230 V)1.1–2.3 kW
Power Rating (400 V)4.5 kW
Standard Shelves2 (max. 4–16 depending on model)
Safety ClassIndependent dual-stage temperature safety device (DIN 12880, Class 2) with optical alarm
InterfaceUSB port for data logging
ComplianceDIN 12880, EN 61000-6-3, EN 61000-6-4, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelL5/13-LT 15/13
TypeBox-Type Muffle Furnace
Max Temperature1300 °C
Temperature Control Accuracy±1 °C
Max Power2.4 kW
Heating Time to Max Temp45 min
Heating MethodDual-Side Radiant Heating
Internal Dimensions (W×D×H)260 × 340 × 170 mm
External Dimensions (W×D×H)530 × 625 × 630 mm
Net Weight70 kg
Voltage SupplySingle-Phase 230 V
Safety ClassThermal Protection Level 2 per EN 60519-2
Gas Inlet PortRear Wall Mounted
Exhaust PortRear Wall Mounted
Optional Door ConfigurationTop-Hinged (LT) or Front-Hinged (L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelM53 / M115 / M240 / M400 / M720
Temperature RangeAmbient +5 °C to 300 °C
Internal Volume53–720 L
External Dimensions (W×H×D)1235 mm × 1690 mm × 865 mm
Internal Dimensions (W×H×D)1000 mm × 1200 mm × 610 mm
Heating MethodForced Convection (Hot Air)
Temperature Uniformity at 150 °C±1.3–1.9 K
Temperature Fluctuation at 150 °C±0.3 K
Heating Time to 150 °C15–21 min
Recovery Time after 30-sec Door Opening at 150 °C≤3 min
Max. Load Capacity40–120 kg
Max. Shelf Load15–45 kg
Standard Shelves2 (adjustable), Max. Shelves: 5–16
Power Rating (230 V)1.2–2.7 kW
Power Rating (400 V)3.45 kW
InterfaceEthernet, USB for Data Logger Export
SafetyDual Independent Temperature Safety Devices (DIN 12880 Class 2 & Class 3.1), Redundant Pt100 Sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelL 1/12 – LT 40/12
Heating Temperature Range1100 °C or 1200 °C
Chamber Volume1–40 L
Power Supply1-phase (230 V) or 3-phase (400 V)
Heating ConfigurationDual-sided ceramic heating plates (triple-sided for L 24/11 – LT 40/12)
InsulationHigh-purity alumina-silica safety fiber
ConstructionDouble-walled stainless steel housing (brushed finish)
Door OptionsFront-opening (L) or top-opening (LT)
Safety ComplianceEN 60519-2, Thermal Protection Class 2
Data LoggingNTLog via USB flash drive
Optional AccessoriesGas purge interface, exhaust chimney with fan/catalyst, VCD process control software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
ModelLE1/11–LE14/11
Max Temperature1100 °C
Operating Temperature1050 °C
Heating ConfigurationDual-sided, heating elements embedded in quartz tubes
InsulationMulti-layer ceramic fiber board
EnclosureDouble-walled brushed stainless steel
Door TypeFront-opening
Exhaust PortRear wall-mounted
Overtemperature ProtectionEN 60519-2 compliant, Class 2 thermal protection with adjustable cutoff temperature
Gas InletRear-mounted manual gas connection
Control SystemControltherm MV software-enabled process control and data logging
Power SupplySingle-phase
Weight10–40 kg (model-dependent)
Dimensions & VolumeModel-specific (e.g., LE1/11: 90×115×110 mm internal, 1290×280×430 mm external, 1.5 L volume, 1.5 kW)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA (Tokyo Rikakikai Co., Ltd.)
OriginJapan
ModelSD-1000
Inlet Temperature Range40–200 °C
Temperature Control Accuracy±1 °C
Max. Evaporation Rate1500 mL/h
Drying Air Flow0.2–0.75 m³/min
Atomizing Air Pressure20–245 kPa
Feed Pump Flow Rate150–1700 mL/h
Stirrer Speed100–1000 rpm
Sample Vessel Capacity50 mL–2 L
Heater Power3 kW
Nozzle TypeTwin-fluid nozzle (standard orifice ID: 0.4 mm)
ConstructionBorosilicate glass evaporation chamber & cyclonic separator
Powder Collection Vessel600 mL borosilicate glass
Safety FeaturesReal-time diagnostics for inlet/outlet temperature deviation, airflow anomaly, heater fault, and feed pressure failure
Auto-cleaning IntervalProgrammable 1–20 min cycles
Analog Output0–10 mV (inlet temp, outlet temp, air flow)
Dimensions (W×D×H)700 × 620 × 1500 mm
Weight~110 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNabertherm
OriginGermany
Model RangeLHT 02/16, LHT 04/16, LHT 08/16, LHT 02/17, LHT 04/17, LHT 08/17, LHT 02/18, LHT 04/18, LHT 08/18
Max Operating Temperature1600 °C / 1750 °C / 1800 °C
Chamber Volume2 L / 4 L / 8 L
Internal Dimensions (W×D×H)90×150×150 mm to 150×300×150 mm
External Dimensions (W×D×H)470×630×760 mm to 470×810×760 mm
Power Supply1-phase (3.0–3.6 kW) or 3-phase (5.2–9.0 kW)
Heating ElementMoSi₂ (Molybdenum Disilicide)
Thermal InsulationHigh-purity ceramic fiber
Temperature SensorType B thermocouple
Overtemperature ProtectionEN 60519-2 compliant dual-stage safety limiter (Class 2 thermal protection)
CoolingDual-wall steel housing with forced-air cooling
Gas InterfaceStandard flanged inlet for inert or reducing atmospheres
Control SystemSCR-based phase-angle power regulation with Controltherm MV software integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
ModelTC-250
Temperature Range–20 °C to +150 °C (depending on controller variant)
Temperature Stability±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX)
Controller OptionsAP (touchscreen, programmable, multi-language), SD (dual-speed pump, Rheocalc-compatible), MX (basic digital display, single-speed pump)
Pump TypeVariable-speed (AP), dual-speed (SD), fixed-speed (MX)
Software IntegrationCompatible with Brookfield Rheocalc v3.0+ for remote programming and data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
ModelTC-550
Temperature Range (MX)–20 °C to +135 °C
Temperature Range (AP)–20 °C to +200 °C
Temperature Range (SD)–20 °C to +170 °C
Temperature Stability (MX)±0.07 °C
Temperature Stability (AP)±0.01 °C
Temperature Stability (SD)±0.04 °C
Control InterfaceMX — large-character LCD
Pump ConfigurationMX — single-speed pump
External CirculationYes
Max Internal Bath Volume Capacity600 mL (standard beaker compatibility)
Software IntegrationCompatible with RheocalcT v3.0+ for remote parameter setting, real-time monitoring, and GLP-compliant data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBINDER
OriginGermany
ModelE28
Instrument TypeStandard Drying Oven
Temperature Range60 °C to 230 °C
Temperature Uniformity±0.5 °C (at 150 °C, steady state)
External Dimensions (W×H×D)580 × 405 × 425 mm
Internal Chamber Dimensions (W×H×D)400 × 280 × 250 mm
Internal Volume28 L
Net Weight (empty)22 kg
Max. Load Capacity25 kg
Max. Load per Shelf10 kg
Heating MethodForced Air (Natural Convection with Fan-Assisted Preheating via APT.line™)
Recovery Time after 30-sec Door Opening (at 150 °C)≤19 min
Heating Time to 150 °C≤36 min
Rated Power0.8 kW (120 V / 230 V)
Shelves Supplied2 chrome-plated adjustable shelves
Timer Range0–120 min
Safety DeviceTemperature Safety Controller Class 1 (DIN 12880)
Exhaust ValveAdjustable mechanical damper
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0