- All
- Favorite
- Popular
- Most rated
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | LH15/12–LF120/14 |
| Max. Temperature | 1200–1400 °C |
| Chamber Dimensions (W×D×H) | 250×250×250 mm to 500×500×500 mm |
| Chamber Volume | 15–216 L |
| External Dimensions (W×D×H) | 680×860×1170 mm to 990×1280×1530 mm |
| Power Supply | 3-phase, 5.0–26.0 kW |
| Weight | 150–470 kg |
| Brand | Huber |
|---|---|
| Origin | Germany |
| Model | CC-K6, CC-K6s, KISS K6, KISS K6s |
| Temperature Range | –25 °C to +200 °C |
| Heating Power | 1.6–2.1 kW |
| Cooling Power (at 20 °C) | 0.72 kW (CC-K6), 0.25 kW (KISS K6), 0.40 kW (CC-K6s), 0.26 kW (KISS K6s) |
| Bath Volume | 4.5 L |
| Bath Opening Dimensions | 140 × 120 mm |
| Bath Depth | 150 mm |
| Pump Flow Rate (Pressure/Suction) | up to 27 L/min @ 0.4 bar / 22 L/min @ 0.15 bar (CC-K6) |
| External Circulation Interface | Yes |
| Temperature Stability | ±0.02 K (CC series), ±0.05 K (KISS series) |
| Refrigerant | Natural (R744 / CO₂ or R290 / propane, per model configuration) |
| Safety Class | DIN 12876 Class III / FL (flammable liquid compatible) |
| Controller | Pilot ONE with 7″ capacitive touchscreen, 11-language UI, RS232 interface, Pt100 sensor input, 2-point calibration, calendar-based scheduling, overtemperature & low-level protection |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | ED-S Solid.Line |
| Instrument Type | Standard Drying Oven |
| Temperature Range | Ambient +7 °C to 250 °C |
| Temperature Uniformity | ±0.8 °C |
| External Dimensions (W×H×D) | 614 × 625 × 577 mm |
| Internal Dimensions (W×H×D) | 400 × 440 × 350 mm |
| Internal Volume | 62 L |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Technology | APT.line™ Preheating Chamber Technology |
| Air Circulation | Natural Convection (Free Convection) |
| Safety | Independent Adjustable Temperature Safety Device, Class 2 (DIN 12880), Optical Alarm |
| Controller | Time-Programmable Digital Controller |
| Accessories | 2 Chrome-Plated Wire Shelving Inserts |
| Exhaust Valve | Adjustable |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | PSL |
| Temperature Range | –40 °C to 0 °C / –80 °C to 0 °C / –80 °C to 20 °C |
| Temperature Stability | ±0.5 °C (PSL-1400) / ±1.0 °C (PSL-1810, PSL-2000) |
| Stirring Speed | 100–800 rpm |
| Heating Power | 250 W / 450 W / 750 W |
| Cooling Capacity | Air-Cooled Compressor System (R404A, R507A/R23 Dual-Circuit) |
| Tank Material | SUS304 Stainless Steel |
| Capacity | 2.1 L / 3.5 L / 8 L |
| Stirring Motor Output | 15 W / 25 W / 25 W |
| Safety Features | Leakage Current Protection, Overcurrent Protection, Overheating Prevention, Compressor High-Pressure Cut-off, Sensor Open-Circuit Detection, Self-Diagnostic Function (Heater Fault, Sensor Anomaly, Temp Deviation Alert), Compressor Delay Start |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | LHT/LB |
| Max. Temperature | 1650 °C |
| Chamber Dimensions (Ø × H) | Ø185 × 185 mm (LHT 02/17 LB) / Ø260 × 260 mm (LHT 16/17 LB) |
| Chamber Volume | 2 L / 16 L |
| External Dimensions (W × D × H) | 390 × 590 × 765 mm / 650 × 1250 × 1980 mm |
| Power Supply | 3.4 kW (1-phase) / 12.0 kW (3-phase) |
| Weight | 50 kg / 410 kg |
| Heating Element | Molybdenum Disilicide (MoSi₂) |
| Temperature Uniformity | ≤ ±5 °C (at 1600 °C, steady state) |
| Control System | SCR-controlled S-type thermocouple with overtemperature protection per EN 60519-2 Class 2 |
| Optional | Protective Gas Inlet, Manual/Automatic Gas Supply, Adjustable Bottom Air Intake, Stackable Crucible Supports, Controltherm MV Process Software |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | R Series |
| Max Operating Temperature | 1200 °C or 1300 °C |
| Tube ID | 50–120 mm |
| Heating Zone Length | 250–1000 mm |
| External Dimensions (W×D×H) | up to 1300 mm × 1170 mm × 460 mm |
| Power Supply | 1-phase (1.6–2.3 kW) or 3-phase (6.5–11.5 kW) |
| Weight | 22–89 kg |
| Control System | HiProSystem (3-zone for models ≥750 mm heating length, 1300 °C), integrated S-type thermocouple, overtemperature protection per EN 60519-2 Class 2 |
| Atmosphere Options | inert gas, vacuum-compatible configurations available |
| Software Integration | Controltherm MV for process monitoring, logging, and compliance-ready data management |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | RT |
| Max. Operating Temperature | 1100 °C / 1300 °C / 1500 °C |
| Tube Diameter (Ø) | 50–150 mm |
| Heating Zone Length | 250–360 mm |
| Uniformity (ΔT @ 10 K) | ±5 K over heating zone |
| Power Supply | 1-phase, 1.8 kW |
| Weight | 25–45 kg |
| Construction Material | C 530 high-alumina refractory tube |
| Thermocouple Type | S-type (detachable from support) |
| Mounting Flexibility | Adjustable height & tilt angle (horizontal, vertical, or inclined operation) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | ED/FD Series |
| Heating Principle | Natural Convection (ED) / Forced Air Convection (FD) |
| Temperature Range | Ambient +5 °C to 300 °C |
| Control System | Microprocessor-based with LED Display & Integrated Timer (0–99 h 59 min or continuous) |
| Safety Class | DIN 12880 Compliant, Dual-Level Thermal Protection (TWB) |
| Chamber Materials | High-Performance Stainless Steel (AISI 304), Electrogalvanized Steel Enclosure with Corrosion-Resistant Coating |
| Chamber Volumes | 23 L, 53 L, 115 L, 240 L, 400 L, 720 L |
| Interface | RS422 for APT-COM Data Management Software (Optional) |
| Interior Design | Rounded Corners, Smooth Welded Surfaces, Removable Shelving, Tempered Glass Inner Door |
| Insulation | Advanced Low-Conductivity Mineral Wool |
| Surface Finish | Anti-Dust Powder Coating |
| Brand | Huber |
|---|---|
| Origin | Germany |
| Model Range | CC-208B, CC-212B, CC-215B, CC-220B, CC-225B, KISS 208B, KISS 212B, KISS 215B, KISS 220B, KISS 225B |
| Temperature Range | −30 °C to +200 °C |
| Heating Power | 1.5–2.1 kW |
| Bath Volume | 7.5–23.5 L |
| Bath Depth | 150–200 mm |
| Opening Dimensions (W×D) | 230×127 mm to 290×329 mm |
| Temperature Stability | ±0.02 K (CC series), ±0.05 K (KISS series) |
| Pressure Pump Flow Rate | 27 L/min @ 0.72 bar (CC), 14 L/min @ 0.25 bar (KISS) |
| Suction Pump Flow Rate | 10.5 L/min @ 0.7 bar (CC & KISS) |
| External Dimensions (W×D×H) | 290×350×375 mm to 350×555×425 mm |
| Construction | AISI 304 stainless steel bath tank |
| Cooling Requirement | External chiller required for operation below ambient or at sustained low temperatures |
| Brand | Huber |
|---|---|
| Origin | Germany |
| Model | Minichillers® |
| Temperature Range | −5 °C to +40 °C (up to +80 °C return fluid temperature) |
| Refrigeration Capacity | 0.25–1.2 kW @ specified setpoints |
| Pump Flow Rate | 10–18 L/min |
| Max. Pressure | 0.3–0.9 bar |
| Dimensions (W×D×H) | 225×360×380 mm to 280×511×424 mm |
| Construction | Stainless steel housing |
| Refrigerant | Natural R744 (CO₂) or R290 (propane), per model |
| Optional | Integrated 1 kW heater (extends range to +100 °C) |
| Interfaces | RS232, USB |
| Display | OLED touchscreen (OLÉ controller) |
| Compliance | CE, RoHS, EN 61000-6-3/6-4, EN 61000-3-2/3-3 |
| Brand | Huber |
|---|---|
| Origin | Germany |
| Model | DC® |
| Temperature Range | –30 °C to +50 °C |
| Refrigeration Capacity | 2.0–4.7 kW (at –20 °C) |
| Dimensions (W×D×H) | 190×250×360 mm (DC30) / 250×310×415 mm (DC31) / 280×340×465 mm (DC32) |
| Refrigerant | R-410A |
| Power Supply | 230 V, 50/60 Hz |
| IP Rating | IP20 |
| Weight | 22–48 kg (model-dependent) |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | RHTH |
| Temperature Range | Up to 1600 °C, 1700 °C or 1800 °C |
| Configuration | Horizontal |
| Heating Zone Length | 150–600 mm |
| Uniformity (ΔT ≤ 10 K) | Over Specified Zone |
| Tube Diameter | 50–120 mm |
| Power Supply | 3-phase, 400 V |
| Total Power | 5.4–14.4 kW |
| Net Weight | 70–110 kg |
| Insulation | Vacuum-formed Ceramic Fiber Boards (Low Thermal Mass) |
| Heating Element | Suspended MoSi₂ |
| Thermocouple Type | Type B (PtRh30/PtRh6) |
| Compliance | EN 60519-2 (Temperature Protection Class II) |
| Control Cabinet | Separate Vertical Enclosure with SCR Power Controller & Low-Voltage Transformer |
| Optional Features | Gas/Vacuum Sealing Flanges, Multi-Zone Temperature Control (3–4 Zones), Work-Tube Internal Thermocouple Monitoring, Backflow Prevention Check Valve, Vertical Mounting Kit (RHTV variant) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-150 |
| Temperature Range (MX) | Ambient +10°C to 135°C |
| Temperature Range (SD/AP) | Ambient +10°C to 150°C |
| Temperature Stability (MX) | ±0.07°C |
| Temperature Stability (SD) | ±0.04°C |
| Temperature Stability (AP) | ±0.01°C |
| Controller Options | MX (basic digital), SD (dual-speed pump, PC-controllable via Rheocalc), AP (touchscreen, programmable, multi-language UI, variable-speed pump) |
| Pump Type | Single-speed (MX), Dual-speed (SD), Variable-speed (AP) |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | HTCT01/14, HTCT08/16 |
| Max Temperature | 1400 °C / 1500 °C / 1600 °C |
| Chamber Dimensions (W×D×H) | 110×120×120 mm to 170×290×170 mm |
| Chamber Volume | 1.5 L to 8.0 L |
| External Dimensions (W×D×H) | 340×300×460 mm to 450×620×570 mm |
| Power Supply | 1-phase or 3-phase |
| Rated Power | 3.5 kW to 13.0 kW |
| Weight | 18 kg to 60 kg |
| Heating Element | Silicon Carbide (SiC) rods |
| Construction | Double-walled stainless steel housing with fiber insulation |
| Door Type | Top-opening (HTCT series) or front-opening (HTC series) |
| Compliance | EN 60519-2 (thermal protection class 2), optional overtemperature limiter |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FD56 / FD115 / FD260 / FD720 |
| Temperature Range | Ambient +10 °C to 300 °C |
| External Dimensions (W×H×D, mm) | 1165×1590×870 |
| Internal Dimensions (W×H×D, mm) | 1000×1300×570 |
| Heating Method | Forced-air circulation (APT.line™ preheating chamber technology) |
| Internal Volume | 60–741 L |
| Max. Load Capacity | 70–315 kg |
| Shelf Load Capacity | 30–45 kg per shelf |
| Temp. Uniformity at 150 °C | ±0.3–±2.5 K |
| Temp. Stability at 150 °C | ±0.3–±0.6 K |
| Heating Time to 150 °C | 15–25 min |
| Recovery Time after Door Opening (150 °C) | 4–6 min |
| Power Rating (230 V) | 1.1–2.3 kW |
| Power Rating (400 V) | 4.5 kW |
| Standard Shelves | 2 (max. 4–16 depending on model) |
| Safety Class | Independent dual-stage temperature safety device (DIN 12880, Class 2) with optical alarm |
| Interface | USB port for data logging |
| Compliance | DIN 12880, EN 61000-6-3, EN 61000-6-4, CE |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | L5/13-LT 15/13 |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1300 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2.4 kW |
| Heating Time to Max Temp | 45 min |
| Heating Method | Dual-Side Radiant Heating |
| Internal Dimensions (W×D×H) | 260 × 340 × 170 mm |
| External Dimensions (W×D×H) | 530 × 625 × 630 mm |
| Net Weight | 70 kg |
| Voltage Supply | Single-Phase 230 V |
| Safety Class | Thermal Protection Level 2 per EN 60519-2 |
| Gas Inlet Port | Rear Wall Mounted |
| Exhaust Port | Rear Wall Mounted |
| Optional Door Configuration | Top-Hinged (LT) or Front-Hinged (L) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | M53 / M115 / M240 / M400 / M720 |
| Temperature Range | Ambient +5 °C to 300 °C |
| Internal Volume | 53–720 L |
| External Dimensions (W×H×D) | 1235 mm × 1690 mm × 865 mm |
| Internal Dimensions (W×H×D) | 1000 mm × 1200 mm × 610 mm |
| Heating Method | Forced Convection (Hot Air) |
| Temperature Uniformity at 150 °C | ±1.3–1.9 K |
| Temperature Fluctuation at 150 °C | ±0.3 K |
| Heating Time to 150 °C | 15–21 min |
| Recovery Time after 30-sec Door Opening at 150 °C | ≤3 min |
| Max. Load Capacity | 40–120 kg |
| Max. Shelf Load | 15–45 kg |
| Standard Shelves | 2 (adjustable), Max. Shelves: 5–16 |
| Power Rating (230 V) | 1.2–2.7 kW |
| Power Rating (400 V) | 3.45 kW |
| Interface | Ethernet, USB for Data Logger Export |
| Safety | Dual Independent Temperature Safety Devices (DIN 12880 Class 2 & Class 3.1), Redundant Pt100 Sensor |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | L 1/12 – LT 40/12 |
| Heating Temperature Range | 1100 °C or 1200 °C |
| Chamber Volume | 1–40 L |
| Power Supply | 1-phase (230 V) or 3-phase (400 V) |
| Heating Configuration | Dual-sided ceramic heating plates (triple-sided for L 24/11 – LT 40/12) |
| Insulation | High-purity alumina-silica safety fiber |
| Construction | Double-walled stainless steel housing (brushed finish) |
| Door Options | Front-opening (L) or top-opening (LT) |
| Safety Compliance | EN 60519-2, Thermal Protection Class 2 |
| Data Logging | NTLog via USB flash drive |
| Optional Accessories | Gas purge interface, exhaust chimney with fan/catalyst, VCD process control software |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model | LE1/11–LE14/11 |
| Max Temperature | 1100 °C |
| Operating Temperature | 1050 °C |
| Heating Configuration | Dual-sided, heating elements embedded in quartz tubes |
| Insulation | Multi-layer ceramic fiber board |
| Enclosure | Double-walled brushed stainless steel |
| Door Type | Front-opening |
| Exhaust Port | Rear wall-mounted |
| Overtemperature Protection | EN 60519-2 compliant, Class 2 thermal protection with adjustable cutoff temperature |
| Gas Inlet | Rear-mounted manual gas connection |
| Control System | Controltherm MV software-enabled process control and data logging |
| Power Supply | Single-phase |
| Weight | 10–40 kg (model-dependent) |
| Dimensions & Volume | Model-specific (e.g., LE1/11: 90×115×110 mm internal, 1290×280×430 mm external, 1.5 L volume, 1.5 kW) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | SD-1000 |
| Inlet Temperature Range | 40–200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max. Evaporation Rate | 1500 mL/h |
| Drying Air Flow | 0.2–0.75 m³/min |
| Atomizing Air Pressure | 20–245 kPa |
| Feed Pump Flow Rate | 150–1700 mL/h |
| Stirrer Speed | 100–1000 rpm |
| Sample Vessel Capacity | 50 mL–2 L |
| Heater Power | 3 kW |
| Nozzle Type | Twin-fluid nozzle (standard orifice ID: 0.4 mm) |
| Construction | Borosilicate glass evaporation chamber & cyclonic separator |
| Powder Collection Vessel | 600 mL borosilicate glass |
| Safety Features | Real-time diagnostics for inlet/outlet temperature deviation, airflow anomaly, heater fault, and feed pressure failure |
| Auto-cleaning Interval | Programmable 1–20 min cycles |
| Analog Output | 0–10 mV (inlet temp, outlet temp, air flow) |
| Dimensions (W×D×H) | 700 × 620 × 1500 mm |
| Weight | ~110 kg |
| Brand | Nabertherm |
|---|---|
| Origin | Germany |
| Model Range | LHT 02/16, LHT 04/16, LHT 08/16, LHT 02/17, LHT 04/17, LHT 08/17, LHT 02/18, LHT 04/18, LHT 08/18 |
| Max Operating Temperature | 1600 °C / 1750 °C / 1800 °C |
| Chamber Volume | 2 L / 4 L / 8 L |
| Internal Dimensions (W×D×H) | 90×150×150 mm to 150×300×150 mm |
| External Dimensions (W×D×H) | 470×630×760 mm to 470×810×760 mm |
| Power Supply | 1-phase (3.0–3.6 kW) or 3-phase (5.2–9.0 kW) |
| Heating Element | MoSi₂ (Molybdenum Disilicide) |
| Thermal Insulation | High-purity ceramic fiber |
| Temperature Sensor | Type B thermocouple |
| Overtemperature Protection | EN 60519-2 compliant dual-stage safety limiter (Class 2 thermal protection) |
| Cooling | Dual-wall steel housing with forced-air cooling |
| Gas Interface | Standard flanged inlet for inert or reducing atmospheres |
| Control System | SCR-based phase-angle power regulation with Controltherm MV software integration |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-250 |
| Temperature Range | –20 °C to +150 °C (depending on controller variant) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Controller Options | AP (touchscreen, programmable, multi-language), SD (dual-speed pump, Rheocalc-compatible), MX (basic digital display, single-speed pump) |
| Pump Type | Variable-speed (AP), dual-speed (SD), fixed-speed (MX) |
| Software Integration | Compatible with Brookfield Rheocalc v3.0+ for remote programming and data logging |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-550 |
| Temperature Range (MX) | –20 °C to +135 °C |
| Temperature Range (AP) | –20 °C to +200 °C |
| Temperature Range (SD) | –20 °C to +170 °C |
| Temperature Stability (MX) | ±0.07 °C |
| Temperature Stability (AP) | ±0.01 °C |
| Temperature Stability (SD) | ±0.04 °C |
| Control Interface | MX — large-character LCD |
| Pump Configuration | MX — single-speed pump |
| External Circulation | Yes |
| Max Internal Bath Volume Capacity | 600 mL (standard beaker compatibility) |
| Software Integration | Compatible with RheocalcT v3.0+ for remote parameter setting, real-time monitoring, and GLP-compliant data logging |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | E28 |
| Instrument Type | Standard Drying Oven |
| Temperature Range | 60 °C to 230 °C |
| Temperature Uniformity | ±0.5 °C (at 150 °C, steady state) |
| External Dimensions (W×H×D) | 580 × 405 × 425 mm |
| Internal Chamber Dimensions (W×H×D) | 400 × 280 × 250 mm |
| Internal Volume | 28 L |
| Net Weight (empty) | 22 kg |
| Max. Load Capacity | 25 kg |
| Max. Load per Shelf | 10 kg |
| Heating Method | Forced Air (Natural Convection with Fan-Assisted Preheating via APT.line™) |
| Recovery Time after 30-sec Door Opening (at 150 °C) | ≤19 min |
| Heating Time to 150 °C | ≤36 min |
| Rated Power | 0.8 kW (120 V / 230 V) |
| Shelves Supplied | 2 chrome-plated adjustable shelves |
| Timer Range | 0–120 min |
| Safety Device | Temperature Safety Controller Class 1 (DIN 12880) |
| Exhaust Valve | Adjustable mechanical damper |