- All
- Favorite
- Popular
- Most rated
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Sensor Types | Tubular, Planar, Fork-Type, TipTop & Custom Configurations |
| Application Scope | Laboratory QC, In-Line Process Monitoring, Batch Sampling |
| Material Compatibility | Powders, Granules, Tablets, Sheets, Fibers, Pellets, Non-Adhesive Bulk Solids |
| Construction | Stainless Steel (AISI 316L) + High-Strength Alumina Ceramic |
| Interface | Analog 4–20 mA / Digital RS-485 / EtherNet/IP (compatible with TEWS MW-E Series Electronics, excluding MW-T) |
| Compliance | CE, RoHS, ATEX Zone 22 (optional), ISO/IEC 17025 traceable calibration support |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 3012 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Temperature | 0–40 °C |
| Analog Input | Product Temperature |
| Analog Output | Measured Values |
| Digital I/O | Control & Status Signals |
| Communication Interfaces | RS-232/RS-485 Serial, Ethernet (10/100BASE-T), CAN 2.0A/B, LAN |
| Max Sampling Rate | 40,000 readings/s |
| Application Scope | In-line moisture & density measurement of fast-moving discrete or continuous materials (e.g., cigarettes, yarns, tablets, capsules, filter rods) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HE83 |
| Maximum Capacity | 81 g |
| Moisture Content Readability | 0.01 % (equivalent to 1 mg at 10 g sample) |
| Repeatability (2 g sample) | 0.15 % SD |
| Repeatability (10 g sample) | 0.05 % SD |
| Drying Temperature Range | 50 °C – 200 °C |
| Temperature Increment | 1 °C |
| Drying Programs | Standard, Rapid, Timed, SOC (Smart Optimization Control), ATRO (Automatic Termination by Rate of Loss) |
| Method Storage | Up to 2 methods |
| Result Storage | 1 result |
| Output Interface | RS232 |
| Display Modes | Moisture %, Solid %, g, ATRO Solid %, ATRO Moisture % |
| Calibration Options | SmartCal, temperature calibration at 100 °C / 160 °C |
| Print Output | Optional thermal paper printer (disabled by default) |
| Language | English |
| Power Supply | 230 V AC |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4300 / MW 4310 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 60 VA |
| Operating Temperature | 0–45 °C |
| Data Interfaces | 2× RS-232 (COM + Service), 1× Ethernet, 3× USB, 1× Analog Input (0/4–20 mA for optional IR sensor), 1× Pt100 temperature sensor input, PS/2 mouse & keyboard + VGA display support |
| Measurement Time | Millisecond-scale |
| Internal Data Storage | 6,000 measurements |
| External Server Storage | Unlimited |
| Display | MW 4300 — integrated 10.4" (26.4 cm) LCD color touchscreen |
| Sample Volume Range | 1–2000 mL |
| Max. Sensor Units Supported | 2 (lab-grade microwave sensors) |
| Calibration Profiles | Up to 200 product-specific calibration curves |
| Software | Pre-installed TEWS Moisture View© |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 µL (burette resolution) |
| One-Click Method Shortcuts | 12 (V20S), 4 (V30S), 12 (C10S), 12 (C20S), 12 (C30S) |
| Solvent Manager | Hardware-integrated, hot-pluggable |
| Smart Burette | RFID-enabled, auto-recognized |
| User Management | 4-level permission system with password protection |
| Software Integration | LabX Express / LabX Server via USB or TCP/IP |
| GLP-Compliant Printing | USB printer or METTLER TOLEDO P25 thermal printer |
| Optional Automation | InMotion KF Heated Autosampler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EVA V1/V3 |
| Application Scope | Liquid and soluble solid samples |
| Titration Principle | Volumetric Karl Fischer (Iodine-based redox titration) |
| Electrode Type | Digital polarizable dual-platinum electrode |
| Control Algorithm | Fast Forward Algorithm (FFA) for real-time current-based endpoint prediction |
| Sample Weight Transfer | Direct integration with METTLER TOLEDO balances via RS232/USB |
| Data Export | CSV, PDF via Ethernet or USB drive |
| Printer Support | METTLER TOLEDO thermal & dot-matrix printers (A4/letter) |
| Software Platform | LabX™ PC-based software with optional Active Directory integration |
| Security Features | User-level access control, audit trail, 21 CFR Part 11–compliant electronic signatures (with LabX validation package) |
| Solvent Handling | Fully automated solvent exchange and burette purging |
| Optional Accessories | Homogenizer kit, micro-vial holders, 2.5 m remote terminal cable for fume hood operation |
| Reproducibility | ≤0.3% RSD for triplicate analysis under GLP conditions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HS153 |
| Heating Source | Halogen Lamp |
| Moisture Content Readability | 0.01 % |
| Minimum Detectable Moisture Content | 0.5 % |
| Repeatability (2 g sample) | 0.05 % (std. dev.) |
| Repeatability (10 g sample) | 0.01 % (std. dev.) |
| Method Storage Capacity | 100 methods |
| Result Storage Capacity | 3,000 results |
| Drying Temperature Range | 40–230 °C (1 °C increment) |
| Max. Sample Capacity | 150 g |
| Display Modes | ATRO moisture %, moisture (g/kg), solids %, solids (g/kg), mass (g), ATRO solids % |
| Drying Programs | Slow, Standard, Fast |
| Auto-End Criteria | SOC 1–5 (standard), user-defined (1–10 mg loss or 5–300 s duration), user-defined % mass loss |
| Calibration & Test Temperatures | 100 °C / 160 °C |
| SmartCal Drying Temperature | 40 °C |
| Connectivity | USB, Ethernet/Wi-Fi, RS232 |
| Supported Languages | English, German, French, Spanish, Italian, Portuguese, Russian, Polish, Czech, Hungarian, Japanese, Korean, Chinese |
| Interface | Touchscreen with guided workflow, method shortcuts, real-time drying curve, control chart, ID management, result prediction, weighing assistance |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 4260 / MW 4270 / MW 4200 |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Power Consumption | 160 VA (MW 4260), 200 VA (MW 4270) |
| Operating Temperature | 0–45 °C |
| Display | 10.4" LED color touchscreen (MW 4270), 5" LCD (MW 4260), single-line LED (MW 4200) |
| Data Interfaces | 1× Ethernet, 1× analog input (0/4–20 mA), 3× analog outputs (0/4–20 mA), 8× passive digital outputs, 8× digital inputs |
| Measurement Rate | up to 3,500 readings per second |
| Internal Data Storage | 60,000 measurements |
| Enclosure Rating | IP55 (industrial duty), ATEX-certified variants available for gas/dust hazardous areas |
| Sensor-to-Display Distance | up to 8 m (MW 4200 optimized for remote mounting) |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1150 |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Measurement Time | <1 s |
| Power Supply | 110–230 V AC, 50–60 Hz |
| Operating Sample Temperature Range | 5–60 °C (with optional Pt100 or IR temperature sensor and auto thermal stabilization compensation) |
| Ambient Temperature Range | 0–40 °C |
| Enclosure Rating | IP20 |
| Display | Backlit LCD graphic display (320 × 240 pixels), 5.7-inch diagonal |
| Internal Memory | EEPROM storage for up to 25 product profiles and 250 measurement records |
| Data Interface | USB (PC connectivity) |
| Analog Output | 0(4)–20 mA with current isolation |
| Software Support | TEWS Moisture View Lite © |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HE53 |
| Heating Source | Halogen Lamp |
| Maximum Capacity | 54 g |
| Moisture Content Readability | 0.01 % (1 mg) |
| Repeatability (2 g sample) | 0.15 % (SD) |
| Repeatability (10 g sample) | 0.05 % (SD) |
| Drying Temperature Range | 50–160 °C |
| Temperature Increment | 1 °C |
| Predefined Drying Programs | Standard, Rapid |
| Method Storage | 1 method |
| Result Storage | 1 result |
| Display Modes | ATRO moisture %, ATRO solids %, mass (g), moisture %, solids % |
| Interface | RS232 |
| Language | English |
| Compliance | ASTM E1447, ISO 18810, USP <921>, GLP-compliant data handling |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg |
| Moisture Content Resolution | 0.001% |
| Repeatability (sd) | 0.01% (10 g sample) / 0.05% (2 g sample) |
| Temperature Range | 40–230 °C |
| Heating Source | Second-generation halogen lamp |
| Heating Control | Programmable ramp profiles (Standard, Gentle, Fast, Step) |
| Automatic Calibration | FACT® (Fully Automatic Calibration Technology) with dual-point temperature calibration and adjustable mass-point weighing calibration |
| Display Modes | % MC, % DC, % ATRO MC/DC, g, g/kg MC, g/kg DC |
| Sample chamber surface | Sealed, smooth, cleanable in ≤30 s |
| Weighing cell location | Rear-mounted, isolated from heating chamber |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | C20S / C30S |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–capable (with LabX Server) |
| Electrode Options | Membrane-free or membrane-separated coulometric electrolysis cell |
| Interface | 7-inch full-color capacitive touchscreen with One Click™ UI |
| Language Support | English, Chinese, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese |
| Connectivity | USB 2.0 (printer, flash drive), Ethernet (TCP/IP), RS232 (optional) |
| User Management | 4-tier permission hierarchy with password protection and audit trail logging |
| Software Integration | LabX Express (standalone), LabX Server (networked, multi-instrument, compliant archiving) |
| Automation Ready | Compatible with InMotion KF Heating Oven Autosampler (C30S only) |
| Solvent Handling | Integrated Solvent Manager with automated reagent dispensing and waste evacuation |
| Certifications | CE, UL, RoHS |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HC103 |
| Maximum Capacity | 101 g |
| Moisture Content Readability | 0.01 % (equivalent to 1 mg at 10 g sample) |
| Repeatability (2 g sample) | 0.1 % (std. dev.) |
| Repeatability (10 g sample) | 0.015 % (std. dev.) |
| Drying Temperature Range | 40–230 °C (1 °C increment) |
| Preset Drying Programs | Standard, Rapid |
| Method Storage | up to 20 methods |
| Result Storage | 100 results |
| Data Output | Thermal printer (paper tape), USB drive, PC software via USB/RS232 |
| Temperature Calibration | SmartCal®, reference temperature points at 100 °C / 160 °C |
| Display Modes | ATRO moisture %, moisture (g/kg), solids %, solids (g/kg), mass (g), ATRO solids % |
| User Interface | 7" color touchscreen with OneClick™ operation |
| Language Support | English, Spanish, French, German, Italian, Portuguese, Russian, Polish, Czech, Hungarian, Japanese, Korean, Chinese |
| Compliance Features | User management, password-protected settings, audit trail-ready configuration, GLP/GMP-supportive data handling |
| Brand | TEWS |
|---|---|
| Origin | Germany |
| Model | MW 1100 |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature Range | 0–40 °C |
| Measurement Time | < 1 s |
| Repeatability | ±0.5% typical standard deviation (material-dependent) |
| Display | 3.5-inch backlit graphical LCD |
| Data Storage | EEPROM, up to 250 measurements |
| Memory Slots | 25 product-specific calibration profiles |
| Power Supply | NiMH rechargeable battery |
| Battery Life | ~5 h (median usage, fully charged) |
| Protection Rating | IP20 |
| Interface | USB |
| Software | TEWS Moisture View Lite © |
Show next