BrandTEWS
OriginGermany
Sensor TypesTubular, Planar, Fork-Type, TipTop & Custom Configurations
Application ScopeLaboratory QC, In-Line Process Monitoring, Batch Sampling
Material CompatibilityPowders, Granules, Tablets, Sheets, Fibers, Pellets, Non-Adhesive Bulk Solids
ConstructionStainless Steel (AISI 316L) + High-Strength Alumina Ceramic
InterfaceAnalog 4–20 mA / Digital RS-485 / EtherNet/IP (compatible with TEWS MW-E Series Electronics, excluding MW-T)
ComplianceCE, RoHS, ATEX Zone 22 (optional), ISO/IEC 17025 traceable calibration support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTEWS
OriginGermany
ModelMW 3012
Power Supply110–230 V AC, 50–60 Hz
Operating Temperature0–40 °C
Analog InputProduct Temperature
Analog OutputMeasured Values
Digital I/OControl & Status Signals
Communication InterfacesRS-232/RS-485 Serial, Ethernet (10/100BASE-T), CAN 2.0A/B, LAN
Max Sampling Rate40,000 readings/s
Application ScopeIn-line moisture & density measurement of fast-moving discrete or continuous materials (e.g., cigarettes, yarns, tablets, capsules, filter rods)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHE83
Maximum Capacity81 g
Moisture Content Readability0.01 % (equivalent to 1 mg at 10 g sample)
Repeatability (2 g sample)0.15 % SD
Repeatability (10 g sample)0.05 % SD
Drying Temperature Range50 °C – 200 °C
Temperature Increment1 °C
Drying ProgramsStandard, Rapid, Timed, SOC (Smart Optimization Control), ATRO (Automatic Termination by Rate of Loss)
Method StorageUp to 2 methods
Result Storage1 result
Output InterfaceRS232
Display ModesMoisture %, Solid %, g, ATRO Solid %, ATRO Moisture %
Calibration OptionsSmartCal, temperature calibration at 100 °C / 160 °C
Print OutputOptional thermal paper printer (disabled by default)
LanguageEnglish
Power Supply230 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTEWS
OriginGermany
ModelMW 4300 / MW 4310
Power Supply110–230 V AC, 50–60 Hz
Power Consumption60 VA
Operating Temperature0–45 °C
Data Interfaces2× RS-232 (COM + Service), 1× Ethernet, 3× USB, 1× Analog Input (0/4–20 mA for optional IR sensor), 1× Pt100 temperature sensor input, PS/2 mouse & keyboard + VGA display support
Measurement TimeMillisecond-scale
Internal Data Storage6,000 measurements
External Server StorageUnlimited
DisplayMW 4300 — integrated 10.4" (26.4 cm) LCD color touchscreen
Sample Volume Range1–2000 mL
Max. Sensor Units Supported2 (lab-grade microwave sensors)
Calibration ProfilesUp to 200 product-specific calibration curves
SoftwarePre-installed TEWS Moisture View©
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
Instrument TypeVolumetric Karl Fischer Moisture Analyzer
Titration ModeFully Automated
Moisture Range10 ppm to 100%
Resolution0.1 µL (burette resolution)
One-Click Method Shortcuts12 (V20S), 4 (V30S), 12 (C10S), 12 (C20S), 12 (C30S)
Solvent ManagerHardware-integrated, hot-pluggable
Smart BuretteRFID-enabled, auto-recognized
User Management4-level permission system with password protection
Software IntegrationLabX Express / LabX Server via USB or TCP/IP
GLP-Compliant PrintingUSB printer or METTLER TOLEDO P25 thermal printer
Optional AutomationInMotion KF Heated Autosampler
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelEVA V1/V3
Application ScopeLiquid and soluble solid samples
Titration PrincipleVolumetric Karl Fischer (Iodine-based redox titration)
Electrode TypeDigital polarizable dual-platinum electrode
Control AlgorithmFast Forward Algorithm (FFA) for real-time current-based endpoint prediction
Sample Weight TransferDirect integration with METTLER TOLEDO balances via RS232/USB
Data ExportCSV, PDF via Ethernet or USB drive
Printer SupportMETTLER TOLEDO thermal & dot-matrix printers (A4/letter)
Software PlatformLabX™ PC-based software with optional Active Directory integration
Security FeaturesUser-level access control, audit trail, 21 CFR Part 11–compliant electronic signatures (with LabX validation package)
Solvent HandlingFully automated solvent exchange and burette purging
Optional AccessoriesHomogenizer kit, micro-vial holders, 2.5 m remote terminal cable for fume hood operation
Reproducibility≤0.3% RSD for triplicate analysis under GLP conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHS153
Heating SourceHalogen Lamp
Moisture Content Readability0.01 %
Minimum Detectable Moisture Content0.5 %
Repeatability (2 g sample)0.05 % (std. dev.)
Repeatability (10 g sample)0.01 % (std. dev.)
Method Storage Capacity100 methods
Result Storage Capacity3,000 results
Drying Temperature Range40–230 °C (1 °C increment)
Max. Sample Capacity150 g
Display ModesATRO moisture %, moisture (g/kg), solids %, solids (g/kg), mass (g), ATRO solids %
Drying ProgramsSlow, Standard, Fast
Auto-End CriteriaSOC 1–5 (standard), user-defined (1–10 mg loss or 5–300 s duration), user-defined % mass loss
Calibration & Test Temperatures100 °C / 160 °C
SmartCal Drying Temperature40 °C
ConnectivityUSB, Ethernet/Wi-Fi, RS232
Supported LanguagesEnglish, German, French, Spanish, Italian, Portuguese, Russian, Polish, Czech, Hungarian, Japanese, Korean, Chinese
InterfaceTouchscreen with guided workflow, method shortcuts, real-time drying curve, control chart, ID management, result prediction, weighing assistance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTEWS
OriginGermany
ModelMW 4260 / MW 4270 / MW 4200
Power Supply110–230 V AC, 50–60 Hz
Power Consumption160 VA (MW 4260), 200 VA (MW 4270)
Operating Temperature0–45 °C
Display10.4" LED color touchscreen (MW 4270), 5" LCD (MW 4260), single-line LED (MW 4200)
Data Interfaces1× Ethernet, 1× analog input (0/4–20 mA), 3× analog outputs (0/4–20 mA), 8× passive digital outputs, 8× digital inputs
Measurement Rateup to 3,500 readings per second
Internal Data Storage60,000 measurements
Enclosure RatingIP55 (industrial duty), ATEX-certified variants available for gas/dust hazardous areas
Sensor-to-Display Distanceup to 8 m (MW 4200 optimized for remote mounting)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTEWS
OriginGermany
ModelMW 1150
Repeatability±0.5% typical standard deviation (material-dependent)
Measurement Time<1 s
Power Supply110–230 V AC, 50–60 Hz
Operating Sample Temperature Range5–60 °C (with optional Pt100 or IR temperature sensor and auto thermal stabilization compensation)
Ambient Temperature Range0–40 °C
Enclosure RatingIP20
DisplayBacklit LCD graphic display (320 × 240 pixels), 5.7-inch diagonal
Internal MemoryEEPROM storage for up to 25 product profiles and 250 measurement records
Data InterfaceUSB (PC connectivity)
Analog Output0(4)–20 mA with current isolation
Software SupportTEWS Moisture View Lite ©
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHE53
Heating SourceHalogen Lamp
Maximum Capacity54 g
Moisture Content Readability0.01 % (1 mg)
Repeatability (2 g sample)0.15 % (SD)
Repeatability (10 g sample)0.05 % (SD)
Drying Temperature Range50–160 °C
Temperature Increment1 °C
Predefined Drying ProgramsStandard, Rapid
Method Storage1 method
Result Storage1 result
Display ModesATRO moisture %, ATRO solids %, mass (g), moisture %, solids %
InterfaceRS232
LanguageEnglish
ComplianceASTM E1447, ISO 18810, USP <921>, GLP-compliant data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHX204
Maximum Capacity200 g
Readability0.1 mg
Moisture Content Resolution0.001%
Repeatability (sd)0.01% (10 g sample) / 0.05% (2 g sample)
Temperature Range40–230 °C
Heating SourceSecond-generation halogen lamp
Heating ControlProgrammable ramp profiles (Standard, Gentle, Fast, Step)
Automatic CalibrationFACT® (Fully Automatic Calibration Technology) with dual-point temperature calibration and adjustable mass-point weighing calibration
Display Modes% MC, % DC, % ATRO MC/DC, g, g/kg MC, g/kg DC
Sample chamber surfaceSealed, smooth, cleanable in ≤30 s
Weighing cell locationRear-mounted, isolated from heating chamber
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelC20S / C30S
ComplianceGLP/GMP-ready, FDA 21 CFR Part 11–capable (with LabX Server)
Electrode OptionsMembrane-free or membrane-separated coulometric electrolysis cell
Interface7-inch full-color capacitive touchscreen with One Click™ UI
Language SupportEnglish, Chinese, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese
ConnectivityUSB 2.0 (printer, flash drive), Ethernet (TCP/IP), RS232 (optional)
User Management4-tier permission hierarchy with password protection and audit trail logging
Software IntegrationLabX Express (standalone), LabX Server (networked, multi-instrument, compliant archiving)
Automation ReadyCompatible with InMotion KF Heating Oven Autosampler (C30S only)
Solvent HandlingIntegrated Solvent Manager with automated reagent dispensing and waste evacuation
CertificationsCE, UL, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHC103
Maximum Capacity101 g
Moisture Content Readability0.01 % (equivalent to 1 mg at 10 g sample)
Repeatability (2 g sample)0.1 % (std. dev.)
Repeatability (10 g sample)0.015 % (std. dev.)
Drying Temperature Range40–230 °C (1 °C increment)
Preset Drying ProgramsStandard, Rapid
Method Storageup to 20 methods
Result Storage100 results
Data OutputThermal printer (paper tape), USB drive, PC software via USB/RS232
Temperature CalibrationSmartCal®, reference temperature points at 100 °C / 160 °C
Display ModesATRO moisture %, moisture (g/kg), solids %, solids (g/kg), mass (g), ATRO solids %
User Interface7" color touchscreen with OneClick™ operation
Language SupportEnglish, Spanish, French, German, Italian, Portuguese, Russian, Polish, Czech, Hungarian, Japanese, Korean, Chinese
Compliance FeaturesUser management, password-protected settings, audit trail-ready configuration, GLP/GMP-supportive data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTEWS
OriginGermany
ModelMW 1100
Sample Temperature Range5–60 °C
Ambient Temperature Range0–40 °C
Measurement Time< 1 s
Repeatability±0.5% typical standard deviation (material-dependent)
Display3.5-inch backlit graphical LCD
Data StorageEEPROM, up to 250 measurements
Memory Slots25 product-specific calibration profiles
Power SupplyNiMH rechargeable battery
Battery Life~5 h (median usage, fully charged)
Protection RatingIP20
InterfaceUSB
SoftwareTEWS Moisture View Lite ©