- All
- Favorite
- Popular
- Most rated
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Dual-Jacketed Reactor |
| Capacity | 1 L |
| Jacket Type | Dual (inner & outer thermal isolation) |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock ΔT | 60 °C |
| Pressure Range | 666 Pa (vacuum) to ambient |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 21 kg |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | AG! 1L Pressure Filtration Reactor |
| Vessel Capacity | 1 L (Note: corrected from misleading “5L” in description |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | Full Vacuum to 0.2 MPa (2 bar(g)) |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (2 × SQG 29/42, 4 × SQG 24/40) |
| Max Stirring Speed | 200 rpm |
| Dimensions (W×D×H) | 455 mm × 432 mm × 1206 mm |
| Net Weight | 33 kg |
| Compliance | Designed per DIN 7080, EN ISO 15500-1, and CE Machinery Directive 2006/42/EC |
| Software Interface | None (standalone mechanical/electromechanical system) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Filter Reactor |
| Vessel Capacity | 5 L |
| Jacketed Design | Yes |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | 666 Pa to atmospheric |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Maximum Agitator Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 33 kg |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | DDL-1000 / DDL-2000 |
| Reactor Type | Jacketed Laboratory Reactor System |
| Temperature Control Modes | Reaction Mass Control, Jacket Control, Isothermal Mode, Gradient Ramp Mode |
| Stirring | Mechanical Agitation (PTFE or SUS304 Impeller) |
| Temp. Range | 10–80 °C (Jacket) |
| Temp. Stability | ±0.1 °C |
| Stirring Speed | 10–1059 rpm |
| Max. Torque | 19.6 N·m (DDL-1000), 0.49 N·m (DDL-2000) |
| Cooling Rate (Jacket) | up to 30 K/min |
| Heating Rate (Jacket) | up to 7.0 K/min |
| Safety Systems | Independent Over-Temperature Protection, Leakage Current Breaker, Low-Coolant-Level Alarm, Emergency Rapid-Cooling Function, SSR Failure Detection, Dual Temperature Limit Alarms |
| Power Supply | AC 100 V, 50/60 Hz (7 A / 700 VA for DDL-1000 |
| Dimensions & Weight | 290×380×790 mm, 20 kg (DDL-1000) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST the High-Performer |
| Usable Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity Handling | 150,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lifting Column Travel | 390 mm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Max. Stirring Torque | 660 N·cm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 1000 Advanced Reactor System |
| Rated Volume | 1 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 to 200 °C |
| Maximum Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Stirring Shaft Max Torque | 100 N·cm |
| Flange Size | DN 100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS-232, Micro-USB |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Vessel Material | DIN 3.3 borosilicate glass |
| Bottom Valve | Spring-loaded PTFE-coated glass valve |
| Lid Ports | 1 × NS 29/32 central, 2 × NS 29/32 side, 1 × NS 14/23 |
| Stirrer | EUROSTAR 100 control with keyless chuck, integrated timer, overload protection & temperature input |
| Agitator Blade | PTFE-coated helical impeller |
| Seal Type | High-vacuum mechanical seal rated to 25 mbar |
| Software Control | labworldsoft® 6 (RS-232 optional) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST Starvisc 200 |
| Working Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity | 100,000 mPa·s |
| Min. Agitation Speed | 6 rpm |
| Lift Stroke | 390 mm |
| Stirring Shaft Max. Torque | 200 N·cm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST the Allrounder |
| Usable Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity | 100,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lifting Stroke | 390 mm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening | 3 × NS 29/32, 2 × NS 14/23 |
| Max. Stirring Torque | 200 N·cm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Control | Microprocessor-based speed regulation with load-compensated stability |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Pressurized Filtration Reactor |
| Vessel Capacity | 5 L |
| Construction | Single-layer borosilicate glass 3.3 vessel |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Pressure Rating | Full vacuum to 0.2 MPaG (2 barg) |
| Wetted Materials | Borosilicate glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (SQG 29/42 × 2, SQG 24/40 × 4) |
| Maximum Stirring Speed | 200 rpm |
| Dimensions (W × D × H) | 455 mm × 432 mm × 1206 mm |
| Weight | 39 kg |
| Modular Configuration | Integrated filtration & drying capability |
| Sealing System | Reinforced magnetic or mechanical shaft seal with leak-proof base design |
| Filtration Base | Removable, pressure-rated sintered frit or filter plate assembly |
| Accessories Included | Pt100 temperature probe, analog pressure gauge, pressure relief valve, quick-connect fluid ports with integrated shut-off valves, PTFE/FFKM-sealed discharge valve |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 5000 Advanced Reactor System |
| Rated Volume | 5 L |
| Minimum Working Volume | 1000 mL |
| Minimum Sample Volume with Temperature Sensor | 1500 mL |
| Operating Temperature Range | –50 to 200 °C |
| Maximum Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Stirring Shaft Max Torque | 100 N·cm |
| Flange Size | DN 150 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS-232, Micro-USB |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Vessel Material | DIN 3.3 borosilicate glass |
| Stirrer Type | EUROSTAR 100 control overhead stirrer |
| Sealing | High-vacuum PTFE/FKM shaft seal |
| Bottom Valve | Spring-loaded glass-safe discharge valve |
| Software Compatibility | labworldsoft® 6 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR 1000 basic System |
| Max. Working Volume | 1000 mL |
| Min. Sample Volume (without disperser) | 500 mL |
| Max. Operating Temperature | 120 °C |
| Vacuum Capability | 25 mbar |
| Max. Viscosity | 100,000 mPa·s |
| Speed Range | 10–150 rpm |
| Stirrer Shaft Diameter (incl. integrated clamp) | 16 mm |
| Wetted Materials | AISI 316L stainless steel (1.4571), Borosilicate Glass 3.3, PTFE, PEEK, FKM |
| Reaction Vessel Opening | 1× NS 29/32, 3× NS 14/23 |
| Continuous Duty Cycle | 100 % |
| Temperature Measurement Accuracy | ±0.1 K |
| Rated Torque | 3 Nm |
| Heating Power Output | 1000 W |
| Cooling Medium Max. Pressure | 1 bar |
| Min. Adjustable Speed | 10 rpm |
| Max. Heating Temperature | 180 °C |
| Adjustable Safety Cut-off Range | 47–225 °C (±10–±20 K deviation) |
| Cooling Medium Min. Inlet Temperature | 3 °C |
| Temp. Control Accuracy (heating) | ±1 K |
| Sensor-Based Temp. Control Accuracy | ±0.2 K |
| Speed Deviation | ±5 rpm |
| Speed Display | LED, 7-segment |
| External Temp. Sensor Interface | PT100 |
| Timer | Yes, LED display |
| Speed Control Resolution | 1 rpm/step |
| Cooling Method | External circulation |
| Temp. Display (cooling circuit) | Yes |
| Safety Temp. Display | LED |
| External Sensor Usage Indicator | Yes |
| Thermal Fuse | Yes |
| Dimensions (W×D×H) | 443 × 360 × 295 mm |
| Weight | 21.897 kg |
| Ambient Operating Temp. | 5–40 °C |
| Max. Relative Humidity | 80 % |
| Protection Class (DIN EN 60529) | IP21 |
| RS232 Interface | Yes |
| USB Interface | Yes |
| Voltage | 230 V |
| Frequency | 50/60 Hz |
| Input Power Rating | 1200 W |
| Optional Voltage Variant | 115 V (R1000 basic variant) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Filtration Reactor |
| Vessel Capacity | 1 L |
| Jacketed Design | Yes |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | 666 Pa to ambient pressure |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Maximum Agitator Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 28 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 1000 Starter Reactor System |
| Rated Volume | 1 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 °C to +200 °C |
| Ultimate Vacuum | 3 mbar |
| Max. Stirring Torque | 60 N·cm |
| Flange Size | DN100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Jacketed Vessel Material | Borosilicate Glass 3.3 |
| Stirrer Type | Overhead Digital Motor (EUROSTAR 60 digital) |
| Sealing | Chemically Resistant FEP-Coated O-Ring & High-Vacuum Shaft Seal |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 500 Advanced Reactor System |
| Rated Volume | 0.5 L |
| Minimum Usable Volume | 30 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 to 200 °C |
| Maximum Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Stirring Shaft Max Torque | 100 N·cm |
| Flange Size | DN100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS232, Micro-USB |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Vessel Material | DIN 3.3 borosilicate glass |
| Stirrer Type | Overhead EUROSTAR 100 control |
| Sealing | High-vacuum PTFE/FEP-coated shaft seal |
| Bottom Valve | Spring-loaded glass-safe discharge valve |
| Control Software | labworldsoft® 6 (RS232-controlled) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | DDS |
| Reactor Capacity | 4 × (50 / 100 / 250 mL, independent) |
| Temperature Control Range | −50 to 250 °C (requires external chiller) |
| Temperature Accuracy | ±0.5 K (−20–100 °C, aluminum block), ±1 K (100–180 °C, aluminum block) |
| Stirring Speed | 125–1000 rpm |
| Max. Heating Rate | Tr < 5.3 K/min, Tj < 19.3 K/min (250 mL water in glass reactor) |
| Max. Cooling Rate | Tr < 7.2 K/min, Tj < 29.6 K/min (250 mL water) |
| Max. Heat Removal Capacity | 0.74–1.1 W/g (200 mL water) |
| Heat Flow Measurement Resolution | 0.1 W, ±5% error (standard conditions) |
| Control Modes | Reactor temperature, aluminum block temperature, gradient, isothermal |
| Control Method | PID heating/cooling + cascade control |
| Liquid Addition | 8-channel volumetric dosing |
| Agitation Type | Propeller stirring |
| Optional pH Control | 0–14, acid/base titration |
| Heat Measurement Principle | Thermal conductivity-based calorimetry with calibration |
| Data Visualization | Real-time & historical trend graphs |
| Safety Systems | Leakage current protection, independent overtemperature cutoff, motor overload protection, software self-diagnosis |
| Flask Ports | Rodaviss 24, NS 14/23 (×3), GL 14 (×1) |
| Vessels | Borosilicate glass, round-bottom, graduated (50 mL or 250 mL) |
| Wetted Materials | Glass, PTFE, PPS, Karlez®, SUS316 |
| Dimensions (W×D×H) | 650 × 490 × 380 mm |
| Weight | ~59 kg |
| Power Supply | AC 100 V, 50 Hz, 2000 VA, 20 A |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Dual-Jacketed Reactor |
| Capacity | 5 L |
| Jacket Configuration | Dual (inner heating/cooling jacket + outer vacuum insulation jacket) |
| Operating Temperature Range | −90 °C to +230 °C |
| Maximum Thermal Shock ΔT | 60 °C |
| Operating Pressure Range | 666 Pa (0.5 mbar) to ambient |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4) |
| Max Stirring Speed | 800 rpm |
| Footprint | 380 mm × 380 mm |
| Height | 1206 mm |
| Net Weight | 28 kg |
| Compliance | Designed for GLP-compliant lab environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AFR Lab |
| Quotation | Upon Request |
| Usable Volume | Medium-Scale |
| Construction Material | Specialty Glass / PFA / PETE / Perfluoroelastomer |
| Operating Pressure | High-Pressure (0–18 bar(g)) |
| Capacity | 2.7 mL per reactor module |
| Vacuum Capability | Not Specified |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Jacketed Reactor |
| Capacity | 5 L |
| Construction | Single-jacketed borosilicate glass 3.3 vessel with PTFE/FFKM wetted parts |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Pressure Range | 666 Pa (vacuum) to ambient pressure |
| Sealing Speed Limit | up to 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 24 kg |
| Port Configuration | 6 ports (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4) |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Advanced-Flow® G1 |
| Pricing | Upon Request |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | SY Stand |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Weight | 20 kg |
| Vessel Compatibility | Jacketed reactors from 500 mL to 5000 mL |
| Mounting Type | Adjustable vertical support stand for overhead stirring systems |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST the Versatile |
| Usable Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity Handling | 70,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lifting Column Travel | 390 mm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Max. Stirring Torque | 100 N·cm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 34 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Control | Microprocessor-based speed regulation with load-compensated stability |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCR-1000G |
| Reactor Type | Flow-through Catalytic Hydrogenation System |
| Max Operating Pressure | 0.4 MPa |
| Temperature Range | Ambient +15°C to 200°C (Aluminum Block Heating Block) |
| Liquid Flow Rate | Up to 0.9 mL/min |
| Gas Flow Rate | Up to 100 mL/min (H₂) |
| Catalyst Cartridge | Stainless Steel Column (Ø5 × 50 mm, replaceable) |
| Wetted Materials | PP (reaction reservoir), Fluoropolymer (fluidic pathways), Perfluoroelastomer (O-rings), SUS316 (glass support components) |
| Power Supply | AC 100 V, 50/60 Hz, 2.5 A, 250 VA |
| Dimensions (W×D×H) | 356 × 461 × 389 mm |
| Safety Features | Pressure-sensor-triggered emergency shutdown, independent overtemperature protection for heating block, heater overload protection, leakage and overcurrent protection, self-diagnostic system, communication failure detection |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Double-Jacketed Glass Reactor with Baffle Plate |
| Capacity | 1 L |
| Jacket Type | Dual vacuum-insulated jacket |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock Limit (ΔT) | 60 °C |
| Pressure Range | 666 Pa (vacuum) to ambient pressure |
| Wetted Materials | Borosilicate glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 22 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 5000 Starter Reactor System |
| Rated Volume | 5 L |
| Minimum Working Volume | 1000 mL |
| Minimum Sample Volume with Temperature Sensor | 1500 mL |
| Operating Temperature Range | −50 °C to +200 °C |
| Maximum Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Stirring Torque | 60 N·cm |
| Flange Size | DN 150 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Vessel Material | DIN ISO 3585 borosilicate glass 3.3 |
| Stirrer Type | PTFE-coated helical propeller |
| Drive | EUROSTAR 60 digital overhead stirrer with keyless chuck |
| Sealing | High-integrity FEP-coated O-ring and vacuum-rated shaft seal |
Show next