BrandIKA
OriginGermany
Model1L Dual-Jacketed Reactor
Capacity1 L
Jacket TypeDual (inner & outer thermal isolation)
Operating Temperature Range−90 °C to +230 °C
Thermal Shock ΔT60 °C
Pressure Range666 Pa (vacuum) to ambient
Wetted MaterialsBorosilicate Glass 3.3, PTFE, FFKM, FKM
Lid Ports6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4)
Max Stirring Speed800 rpm
Dimensions (W×D×H)380 mm × 380 mm × 1206 mm
Weight21 kg
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelAG! 1L Pressure Filtration Reactor
Vessel Capacity1 L (Note: corrected from misleading “5L” in description
Operating Temperature Range−90 °C to +200 °C
Thermal Shock Resistance (ΔT)110 °C
Operating Pressure RangeFull Vacuum to 0.2 MPa (2 bar(g))
Wetted MaterialsBorosilicate Glass 3.3, PTFE, FFKM, FKM
Lid Ports6 × standardized ground joints (2 × SQG 29/42, 4 × SQG 24/40)
Max Stirring Speed200 rpm
Dimensions (W×D×H)455 mm × 432 mm × 1206 mm
Net Weight33 kg
ComplianceDesigned per DIN 7080, EN ISO 15500-1, and CE Machinery Directive 2006/42/EC
Software InterfaceNone (standalone mechanical/electromechanical system)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Model5L Filter Reactor
Vessel Capacity5 L
Jacketed DesignYes
Operating Temperature Range−90 °C to +200 °C
Thermal Shock Resistance (ΔT)110 °C
Operating Pressure Range666 Pa to atmospheric
Wetted MaterialsBorosilicate Glass 3.3, PTFE, FFKM, FKM
Lid Ports6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4)
Maximum Agitator Speed800 rpm
Dimensions (W×D×H)380 mm × 380 mm × 1206 mm
Weight33 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA (Tokyo Rikakikai Co., Ltd.)
OriginJapan
ModelDDL-1000 / DDL-2000
Reactor TypeJacketed Laboratory Reactor System
Temperature Control ModesReaction Mass Control, Jacket Control, Isothermal Mode, Gradient Ramp Mode
StirringMechanical Agitation (PTFE or SUS304 Impeller)
Temp. Range10–80 °C (Jacket)
Temp. Stability±0.1 °C
Stirring Speed10–1059 rpm
Max. Torque19.6 N·m (DDL-1000), 0.49 N·m (DDL-2000)
Cooling Rate (Jacket)up to 30 K/min
Heating Rate (Jacket)up to 7.0 K/min
Safety SystemsIndependent Over-Temperature Protection, Leakage Current Breaker, Low-Coolant-Level Alarm, Emergency Rapid-Cooling Function, SSR Failure Detection, Dual Temperature Limit Alarms
Power SupplyAC 100 V, 50/60 Hz (7 A / 700 VA for DDL-1000
Dimensions & Weight290×380×790 mm, 20 kg (DDL-1000)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelLR-2.ST the High-Performer
Usable Volume500–2000 mL
Temperature RangeAmbient to 230 °C
Vacuum CapabilityDown to 25 mbar
Max. Viscosity Handling150,000 mPa·s
Speed Range8–290 rpm
Lifting Column Travel390 mm
Wetted MaterialsBorosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571
Reactor Opening Configuration3× NS 29/32 + 2× NS 14/23
Max. Stirring Torque660 N·cm
Dimensions (W×H×D)460 × 1240 × 430 mm
Weight25 kg
Ambient Operating Conditions5–40 °C, ≤80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelEasySyn 1000 Advanced Reactor System
Rated Volume1 L
Minimum Usable Volume120 mL
Minimum Sample Volume with Temperature Sensor260 mL
Operating Temperature Range−50 to 200 °C
Maximum Vacuum3 mbar (process), 25 mbar (seal rating)
Stirring Shaft Max Torque100 N·cm
Flange SizeDN 100
Dimensions (W × H × D)500 × 950 × 580 mm
InterfacesRS-232, Micro-USB
Jacket Drain SystemLT 5.40 Quick-Drain Unit
Vessel MaterialDIN 3.3 borosilicate glass
Bottom ValveSpring-loaded PTFE-coated glass valve
Lid Ports1 × NS 29/32 central, 2 × NS 29/32 side, 1 × NS 14/23
StirrerEUROSTAR 100 control with keyless chuck, integrated timer, overload protection & temperature input
Agitator BladePTFE-coated helical impeller
Seal TypeHigh-vacuum mechanical seal rated to 25 mbar
Software Controllabworldsoft® 6 (RS-232 optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelLR-2.ST Starvisc 200
Working Volume500–2000 mL
Temperature RangeAmbient to 230 °C
Vacuum CapabilityDown to 25 mbar
Max. Viscosity100,000 mPa·s
Min. Agitation Speed6 rpm
Lift Stroke390 mm
Stirring Shaft Max. Torque200 N·cm
Wetted MaterialsBorosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571
Reactor Opening Configuration3× NS 29/32 + 2× NS 14/23
Dimensions (W×H×D)460 × 1240 × 430 mm
Weight25 kg
Ambient Operating Conditions5–40 °C, ≤80 % RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelLR-2.ST the Allrounder
Usable Volume500–2000 mL
Temperature RangeAmbient to 230 °C
Vacuum CapabilityDown to 25 mbar
Max. Viscosity100,000 mPa·s
Speed Range8–290 rpm
Lifting Stroke390 mm
Wetted MaterialsBorosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571
Reactor Opening3 × NS 29/32, 2 × NS 14/23
Max. Stirring Torque200 N·cm
Dimensions (W×H×D)460 × 1240 × 430 mm
Weight25 kg
Ambient Operating Conditions5–40 °C, ≤80% RH
ControlMicroprocessor-based speed regulation with load-compensated stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Model5L Pressurized Filtration Reactor
Vessel Capacity5 L
ConstructionSingle-layer borosilicate glass 3.3 vessel
Operating Temperature Range−90 °C to +200 °C
Thermal Shock Resistance (ΔT)110 °C
Pressure RatingFull vacuum to 0.2 MPaG (2 barg)
Wetted MaterialsBorosilicate glass 3.3, PTFE, FFKM, FKM
Lid Ports6 × standardized ground joints (SQG 29/42 × 2, SQG 24/40 × 4)
Maximum Stirring Speed200 rpm
Dimensions (W × D × H)455 mm × 432 mm × 1206 mm
Weight39 kg
Modular ConfigurationIntegrated filtration & drying capability
Sealing SystemReinforced magnetic or mechanical shaft seal with leak-proof base design
Filtration BaseRemovable, pressure-rated sintered frit or filter plate assembly
Accessories IncludedPt100 temperature probe, analog pressure gauge, pressure relief valve, quick-connect fluid ports with integrated shut-off valves, PTFE/FFKM-sealed discharge valve
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelEasySyn 5000 Advanced Reactor System
Rated Volume5 L
Minimum Working Volume1000 mL
Minimum Sample Volume with Temperature Sensor1500 mL
Operating Temperature Range–50 to 200 °C
Maximum Vacuum3 mbar (process), 25 mbar (seal rating)
Stirring Shaft Max Torque100 N·cm
Flange SizeDN 150
Dimensions (W × H × D)500 × 950 × 580 mm
InterfacesRS-232, Micro-USB
Jacket Drain SystemLT 5.40 Quick-Drain Unit
Vessel MaterialDIN 3.3 borosilicate glass
Stirrer TypeEUROSTAR 100 control overhead stirrer
SealingHigh-vacuum PTFE/FKM shaft seal
Bottom ValveSpring-loaded glass-safe discharge valve
Software Compatibilitylabworldsoft® 6
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelLR 1000 basic System
Max. Working Volume1000 mL
Min. Sample Volume (without disperser)500 mL
Max. Operating Temperature120 °C
Vacuum Capability25 mbar
Max. Viscosity100,000 mPa·s
Speed Range10–150 rpm
Stirrer Shaft Diameter (incl. integrated clamp)16 mm
Wetted MaterialsAISI 316L stainless steel (1.4571), Borosilicate Glass 3.3, PTFE, PEEK, FKM
Reaction Vessel Opening1× NS 29/32, 3× NS 14/23
Continuous Duty Cycle100 %
Temperature Measurement Accuracy±0.1 K
Rated Torque3 Nm
Heating Power Output1000 W
Cooling Medium Max. Pressure1 bar
Min. Adjustable Speed10 rpm
Max. Heating Temperature180 °C
Adjustable Safety Cut-off Range47–225 °C (±10–±20 K deviation)
Cooling Medium Min. Inlet Temperature3 °C
Temp. Control Accuracy (heating)±1 K
Sensor-Based Temp. Control Accuracy±0.2 K
Speed Deviation±5 rpm
Speed DisplayLED, 7-segment
External Temp. Sensor InterfacePT100
TimerYes, LED display
Speed Control Resolution1 rpm/step
Cooling MethodExternal circulation
Temp. Display (cooling circuit)Yes
Safety Temp. DisplayLED
External Sensor Usage IndicatorYes
Thermal FuseYes
Dimensions (W×D×H)443 × 360 × 295 mm
Weight21.897 kg
Ambient Operating Temp.5–40 °C
Max. Relative Humidity80 %
Protection Class (DIN EN 60529)IP21
RS232 InterfaceYes
USB InterfaceYes
Voltage230 V
Frequency50/60 Hz
Input Power Rating1200 W
Optional Voltage Variant115 V (R1000 basic variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Model1L Filtration Reactor
Vessel Capacity1 L
Jacketed DesignYes
Operating Temperature Range−90 °C to +200 °C
Thermal Shock Resistance (ΔT)110 °C
Operating Pressure Range666 Pa to ambient pressure
Wetted MaterialsBorosilicate Glass 3.3, PTFE, FFKM, FKM
Lid Ports6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4)
Maximum Agitator Speed800 rpm
Dimensions (W×D×H)380 mm × 380 mm × 1206 mm
Weight28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelEasySyn 1000 Starter Reactor System
Rated Volume1 L
Minimum Usable Volume120 mL
Minimum Sample Volume with Temperature Sensor260 mL
Operating Temperature Range−50 °C to +200 °C
Ultimate Vacuum3 mbar
Max. Stirring Torque60 N·cm
Flange SizeDN100
Dimensions (W × H × D)500 × 950 × 580 mm
Jacketed Vessel MaterialBorosilicate Glass 3.3
Stirrer TypeOverhead Digital Motor (EUROSTAR 60 digital)
SealingChemically Resistant FEP-Coated O-Ring & High-Vacuum Shaft Seal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelEasySyn 500 Advanced Reactor System
Rated Volume0.5 L
Minimum Usable Volume30 mL
Minimum Sample Volume with Temperature Sensor260 mL
Operating Temperature Range−50 to 200 °C
Maximum Vacuum3 mbar (process), 25 mbar (seal rating)
Stirring Shaft Max Torque100 N·cm
Flange SizeDN100
Dimensions (W × H × D)500 × 950 × 580 mm
InterfacesRS232, Micro-USB
Jacket Drain SystemLT 5.40 Quick-Drain Unit
Vessel MaterialDIN 3.3 borosilicate glass
Stirrer TypeOverhead EUROSTAR 100 control
SealingHigh-vacuum PTFE/FEP-coated shaft seal
Bottom ValveSpring-loaded glass-safe discharge valve
Control Softwarelabworldsoft® 6 (RS232-controlled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA (Tokyo Rikakikai Co., Ltd.)
OriginJapan
ModelDDS
Reactor Capacity4 × (50 / 100 / 250 mL, independent)
Temperature Control Range−50 to 250 °C (requires external chiller)
Temperature Accuracy±0.5 K (−20–100 °C, aluminum block), ±1 K (100–180 °C, aluminum block)
Stirring Speed125–1000 rpm
Max. Heating RateTr < 5.3 K/min, Tj < 19.3 K/min (250 mL water in glass reactor)
Max. Cooling RateTr < 7.2 K/min, Tj < 29.6 K/min (250 mL water)
Max. Heat Removal Capacity0.74–1.1 W/g (200 mL water)
Heat Flow Measurement Resolution0.1 W, ±5% error (standard conditions)
Control ModesReactor temperature, aluminum block temperature, gradient, isothermal
Control MethodPID heating/cooling + cascade control
Liquid Addition8-channel volumetric dosing
Agitation TypePropeller stirring
Optional pH Control0–14, acid/base titration
Heat Measurement PrincipleThermal conductivity-based calorimetry with calibration
Data VisualizationReal-time & historical trend graphs
Safety SystemsLeakage current protection, independent overtemperature cutoff, motor overload protection, software self-diagnosis
Flask PortsRodaviss 24, NS 14/23 (×3), GL 14 (×1)
VesselsBorosilicate glass, round-bottom, graduated (50 mL or 250 mL)
Wetted MaterialsGlass, PTFE, PPS, Karlez®, SUS316
Dimensions (W×D×H)650 × 490 × 380 mm
Weight~59 kg
Power SupplyAC 100 V, 50 Hz, 2000 VA, 20 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Model5L Dual-Jacketed Reactor
Capacity5 L
Jacket ConfigurationDual (inner heating/cooling jacket + outer vacuum insulation jacket)
Operating Temperature Range−90 °C to +230 °C
Maximum Thermal Shock ΔT60 °C
Operating Pressure Range666 Pa (0.5 mbar) to ambient
Wetted MaterialsBorosilicate Glass 3.3, PTFE, FFKM, FKM
Lid Ports6 × standardized ground joints (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4)
Max Stirring Speed800 rpm
Footprint380 mm × 380 mm
Height1206 mm
Net Weight28 kg
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
ModelAFR Lab
QuotationUpon Request
Usable VolumeMedium-Scale
Construction MaterialSpecialty Glass / PFA / PETE / Perfluoroelastomer
Operating PressureHigh-Pressure (0–18 bar(g))
Capacity2.7 mL per reactor module
Vacuum CapabilityNot Specified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Model5L Jacketed Reactor
Capacity5 L
ConstructionSingle-jacketed borosilicate glass 3.3 vessel with PTFE/FFKM wetted parts
Operating Temperature Range−90 °C to +230 °C
Thermal Shock Resistance (ΔT)110 °C
Pressure Range666 Pa (vacuum) to ambient pressure
Sealing Speed Limitup to 800 rpm
Dimensions (W×D×H)380 mm × 380 mm × 1206 mm
Weight24 kg
Port Configuration6 ports (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCorning
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAdvanced-Flow® G1
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelSY Stand
Dimensions (W × H × D)500 × 950 × 580 mm
Weight20 kg
Vessel CompatibilityJacketed reactors from 500 mL to 5000 mL
Mounting TypeAdjustable vertical support stand for overhead stirring systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelLR-2.ST the Versatile
Usable Volume500–2000 mL
Temperature RangeAmbient to 230 °C
Vacuum CapabilityDown to 25 mbar
Max. Viscosity Handling70,000 mPa·s
Speed Range8–290 rpm
Lifting Column Travel390 mm
Wetted MaterialsBorosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571
Reactor Opening Configuration3× NS 29/32 + 2× NS 14/23
Max. Stirring Torque100 N·cm
Dimensions (W×H×D)460 × 1240 × 430 mm
Weight34 kg
Ambient Operating Conditions5–40 °C, ≤80 % RH
ControlMicroprocessor-based speed regulation with load-compensated stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA (Tokyo Rikakikai Co., Ltd.)
OriginJapan
ModelCCR-1000G
Reactor TypeFlow-through Catalytic Hydrogenation System
Max Operating Pressure0.4 MPa
Temperature RangeAmbient +15°C to 200°C (Aluminum Block Heating Block)
Liquid Flow RateUp to 0.9 mL/min
Gas Flow RateUp to 100 mL/min (H₂)
Catalyst CartridgeStainless Steel Column (Ø5 × 50 mm, replaceable)
Wetted MaterialsPP (reaction reservoir), Fluoropolymer (fluidic pathways), Perfluoroelastomer (O-rings), SUS316 (glass support components)
Power SupplyAC 100 V, 50/60 Hz, 2.5 A, 250 VA
Dimensions (W×D×H)356 × 461 × 389 mm
Safety FeaturesPressure-sensor-triggered emergency shutdown, independent overtemperature protection for heating block, heater overload protection, leakage and overcurrent protection, self-diagnostic system, communication failure detection
ComplianceDesigned for GLP-compliant laboratory environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Model1L Double-Jacketed Glass Reactor with Baffle Plate
Capacity1 L
Jacket TypeDual vacuum-insulated jacket
Operating Temperature Range−90 °C to +230 °C
Thermal Shock Limit (ΔT)60 °C
Pressure Range666 Pa (vacuum) to ambient pressure
Wetted MaterialsBorosilicate glass 3.3, PTFE, FFKM, FKM
Lid Ports6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4)
Max Stirring Speed800 rpm
Dimensions (W×D×H)380 mm × 380 mm × 1206 mm
Weight22 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelEasySyn 5000 Starter Reactor System
Rated Volume5 L
Minimum Working Volume1000 mL
Minimum Sample Volume with Temperature Sensor1500 mL
Operating Temperature Range−50 °C to +200 °C
Maximum Vacuum3 mbar (process), 25 mbar (seal rating)
Stirring Torque60 N·cm
Flange SizeDN 150
Dimensions (W × H × D)500 × 950 × 580 mm
Vessel MaterialDIN ISO 3585 borosilicate glass 3.3
Stirrer TypePTFE-coated helical propeller
DriveEUROSTAR 60 digital overhead stirrer with keyless chuck
SealingHigh-integrity FEP-coated O-ring and vacuum-rated shaft seal
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0