Empowering Scientific Discovery

Dongnan Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFormulaction (Microtrac)
OriginFrance
ModelTURBISCAN AGS
Light Source880 nm pulsed near-infrared LED
Measurement PrincipleMultiple Light Scattering (MLS)
Particle Size Range0.05–1000 µm
Maximum Volume Concentration95% v/v
Temperature Control RangeRT + 5°C to 60°C
Temperature Accuracy±0.5°C
Scan Height55 mm
Spatial Resolution40 µm
Scan IntervalAs low as 20 s per scan
Programmable Scan SequencesUp to 250
Sample Capacity54 positions
Dimensions (W×D×H)145 × 75 × 85 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFormulaction
OriginFrance
ModelTRI-LAB
Light Source880 nm NIR LED
Sample Volume1.5–30 mL
Temperature Range20–60 °C
Sample Positions1–3
Concentration Range0.0001–95% v/v
Detection PrincipleSynchronized Transmittance (T) and Backscattering (BS) Profiling
Measurement ModeNon-invasive, label-free, no dilution required
ComplianceDesigned for GLP/GMP-aligned pharmaceutical stability assessment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFormulaction (Microtrac)
OriginFrance
ModelTURBISCAN LAB
Light Source880 nm pulsed near-infrared LED
Measurement PrincipleMultiple Light Scattering (MLS)
Particle Size Range0.01–1000 µm
Maximum Volume Concentrationup to 95% v/v
Temperature Control RangeRT + 5 °C to 60 °C
Temperature Accuracy±0.5 °C
Scan Height55 mm
Spatial Resolution20 µm
Dimensions (W × D × H)38 × 42 × 32 cm
Sample Capacity1 tube per run
Data Acquisition ModesFull-height scanning (every 20 µm) or fixed-position kinetic monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFormulaction (Microtrac)
OriginFrance
ModelTURBISCAN TOWER
Light Source880 nm pulsed NIR LED
Measurement PrincipleMultiple Light Scattering (MLS)
Particle Size Range0.01–1000 µm
Max. Volume Concentration95% v/v
Temperature Control Range4–80 °C
Temp. Accuracy±0.1 °C
Scan Height55 mm
Spatial Resolution20 µm
Scan Frequency1 scan per 20 s (at ambient)
Temp. Regulation IntervalEvery 30 s
Max. Programmable Scan Steps250
Sample Capacity6 positions
Dimensions (W×D×H)35 × 45 × 90 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFormulaction
OriginFrance
ModelDNS
Measurement PrincipleStatic Multiple Light Scattering (SMLS)
Sample Volume1.5–30 mL
Concentration Range0.0001–95% v/v
Particle Size Range10 nm–1 mm
Detection ModesTransmitted Light (T) & Backscattered Light (BS)
Scan ModeVertical high-frequency scanning of static sample
Optional FunctionsT-MIX (in-situ stirring), T-LOOP (circulation coupling)
Output MetricTurbiscan Stability Index (TSI)
Compliance ContextDesigned for GLP-compliant formulation development and stability assessment per ICH Q1/Q5, USP <729>, ISO 13321