Empowering Scientific Discovery

Dongnan Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModeleasySpiral®
Dispensing Volume1000 µL
Preset Volumes50 µL or 100 µL
Counting Range300–1.3 × 10⁵ CFU/mL
Cycle Time25 s
Overflow Pressure8 bar
Disinfectant Capacity (Standard Mode)600 cycles per 2 L bottle
Same-Sample Continuous Platingup to 20 Petri Dishes (50 µL each)
Auto-Disinfection ProtocolYes
Compatible Dish Diameter90 mm
Inoculation PatternExponential Spiral & Circular Spiral
Dimensions38 × 42 × 29 cm
Weight15.6 kg
Power Supply100–240 V, 50/60 Hz
ComplianceAFNOR V08-100, ISO 7218
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModeleasySpira Dilutel®
Syringe Capacity1000 µL
Preset Inoculation Volumes50 µL, 100 µL, 200 µL
Counting Range30–1×10¹² CFU/mL
Cycle Time (1 aspiration + 1 disinfection + 1 plating)25 s
Cycle Time (1 disinfection + 5 dilutions + 1 plating at one dilution factor)134 s
Cycle Time (1 disinfection + 5 dilutions + 1 plating per dilution factor)234 s
Needle Pressureup to 8 bar
Automatic Disinfection Cycles1000 cycles (using 2 L bottle)
Automatic Dilution Cycles63 cycles (using 2 L bottle)
Compatible DiluentsSaline, Ringer’s solution
Max. Petri Dishes per Sample (50 µL)20
Spiral Plating ModeOptional (Ø90 mm & Ø150 mm dishes)
Loop Plating ModeOptional (3 dilutions on Ø90 mm
Uniform Plating ModeOptional (Ø55 mm, Ø90 mm, Ø150 mm)
Pour Plate ModeOptional (Ø55 mm, Ø90 mm, Ø150 mm)
Editable Inoculation Volume via USB10–1000 µL
TraceabilityExcel™ export, LIMS integration, DataLink™ compatibility
Sterilizable ComponentsTwo autoclavable bottles (diluent & disinfectant) + connectors
Cross-Contamination PreventionOverflow cleaning technology
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModeleasySpiral Pro
ComplianceAFNOR V08-100, ISO 7218, SN/T 2098–2008
Sample Volume Range10–1000 µL (programmable via USB)
Plating Time≤25 s per plate (including wash, aspirate, and spiral deposition)
Detection Range30–1.1 × 10⁷ CFU/mL
SterilizationAutoclavable components (GL45 bottle adapters, needle assembly, base plate)
Cleaning SystemOverflow-based internal/external needle rinse with real-time fluid-level sensing
ConnectivityUSB interface for method programming, audit trail export, and GLP-compliant data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModeleasySpiral Pro®
Dispensing Volume1000 µL
Preset Volumes50, 100, or 200 µL
Counting Range100–1×10⁷ CFU/mL
Cycle Time25 s
Overflow Pressure8 bar
Disinfectant Capacity (Standard Mode)600 cycles (2 L bottle)
Same-Sample Sequential Platingup to 50 Petri dishes (50 µL each)
Automatic Disinfection ProtocolCompatible with 90 mm and 150 mm Petri dishes
Spiral ModesExponential, Circular, Uniform
Data ExportExcel™ format
Programmable Volume Range10–1000 mL
Dimensions38 × 42 × 29 cm
Weight15.6 kg
Power Supply100–240 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscience
OriginFrance
ModeleasySpiral Pro Milk
Syringe Capacity1000 µL
Preset Volumes50 µL, 100 µL, 200 µL
Adjustable Volume Range10–1000 µL via USB
Sample Input FormatTube (80 × 35 mm)
CFU Counting Range10²–10⁷ CFU/mL
Cycle Time (aspiration + disinfection + plating)25 s
Needle Pressureup to 8 bar
Auto-Disinfection Cycles per 2 L Bottle1000
Auto-Rinse Cycles per 2 L Bottle600
Max. Plates per Sample20 (at 50 µL)
Compatible Petri Dish DiametersØ90 mm and Ø150 mm
Plating ModesSpiral (logarithmic), Pour, Loop (circular), Uniform
ComplianceISO 7218, ISO 4833-2, FDA BAM, AOAC 977.27
Voltage/Frequency100–240 V~, 50–60 Hz
FuseT1.6A L 250V, 5 × 20 mm
Power Consumption45 W
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0