- All
- Favorite
- Popular
- Most rated
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP3007B-II |
| Standard Compliance | GB/T 7305, ASTM D1401, SY/T 5654 |
| Test Temperatures | 54 °C ±1 °C and 82 °C ±1 °C |
| Viscosity Range | 28.8–90 mm²/s (at 40 °C) for 54 °C test |
| Bath Dimensions | Φ240 mm × 255 mm (hardened heat-resistant borosilicate glass) |
| Cylinder Dimensions | Φ32 mm × 230 mm (borosilicate glass), scale range 5–100 mL, graduation interval 1.0 mL, red reference line at 6 mm above bottom |
| Stirrer Blade | stainless steel, 120 mm ±1.5 mm (L) × 19 mm ±0.5 mm (W) × 1.5 mm (T) |
| Stirrer Shaft | stainless steel, Φ6 mm |
| Motor Speed | 1500 ±15 rpm |
| Heating Power | 500 W |
| Power Supply | 220 V ±10 %, 50 Hz ±1 Hz |
| Stirring Duration Control | programmable time relay with audible alert |
| Sample Capacity | three simultaneous test positions with independent thermal pre-conditioning capability |
| Test Method | SH/T 0770, ASTM D5972, IP 435 |
|---|---|
| Temperature Range | +20 °C to –80 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Repeatability | ±0.5 °C |
| Reproducibility | ±0.8 °C |
| Sample Volume | 0.14–0.16 mL |
| Test Duration | ~15 min |
| Cooling Rate | 15 °C/min ±5 °C/min (adjustable) |
| Heating Rate | 10 °C/min ±0.5 °C/min |
| Detection Principle | Optical Phase Transition Sensing |
| Refrigeration System | Hybrid Peltier/Compressor |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Display | 12″ Capacitive Touchscreen |
| Data Storage Capacity | ≥5000 test records |
| Interface | USB, RJ-45 (LIMS-compatible) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 430 × 510 × 560 mm |
| Net Weight | 37 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1013 |
| Light Source | 220 V AC, 100 W frosted incandescent lamp (color temperature 2750 ± 50 K) |
| Color Comparison Tube | Clear, colorless, flat-bottomed glass tube, internal diameter Φ32 mm, height 120–130 mm |
| Standard Color Disc | 26 apertures (Φ14 mm), 25 containing ASTM D1500/GB/T 6540/ISO-compliant colored glass filters (No. 1–25), one blank aperture |
| Optical Viewing System | Dual-lens eyepiece comprising concave and convex lenses enabling side-by-side hemi-circular visual comparison with independent brightness adjustment and focus control |
| Dimensions (L×W×H) | 260 × 300 × 250 mm |
| Net Weight | 15 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2302-II |
| Standards Compliance | ASTM D6371, SH/T 0248, IP 309 |
| Temperature Range | Ambient to –67 °C |
| CFPP Measurement Range | Ambient to –51 °C |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Control | 2 kPa ±0.05 kPa |
| Sample Volume | ~45 mL |
| Cooling Method | Metal Bath with Cascade Compressor |
| Data Storage | ≥5000 Tests |
| Interface | RJ-45 for LIMS Integration |
| Power | AC 220 V ±10 %, 50/60 Hz |
| Dimensions | 660 × 600 × 640 mm |
| Weight | 85 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY1002-II |
| Operation | Fully Automatic |
| Compliant Standards | ASTM D93, GB/T 261, ISO 2719, IP 34 |
| Flash Point Range | 40–370 °C |
| Temperature Display Resolution | 0.1 °C |
| Heating Rates | Step A: 5–6 °C/min |
| Step B | 1.0–1.5 °C/min |
| Step C | 2.5–3.5 °C/min |
| Stirring Speeds | Step A: 90–120 r/min |
| Step B | 250 ±10 r/min |
| Step C | 90–120 r/min |
| Ignition Modes | Electronic or Gas (LPG, butane, natural gas <10 kPa) |
| Safety Cut-off | EFP+20 °C (flash mode), absolute limit 400 °C |
| Cooling | High-efficiency forced-air system |
| Data Interface | RJ-45 for LIMS integration |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 525 × 365 mm |
| Net Weight | 20 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY1030-I |
| Temperature Range | −40 °C to +5 °C |
| Temperature Stability | ±0.005 °C |
| Temperature Resolution | 0.001 °C |
| Bath Capacity | ~65 L |
| Number of Test Ports | 6 |
| Cooling System | Dual Compressor (Primary/Backup Auto-Switching) |
| Stirring System | Dual-Blade Impeller + Optimized Flow Guide Cylinder |
| Insulation | Double-Layer Vacuum Glass + Black Polyoxymethylene (POM) Lid |
| Display | LCD Touchscreen Interface |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 4700 W |
| Dimensions (W×D×H) | 600 × 730 × 1580 mm |
| Net Weight | 230 kg |
| Compliance | GB/T 265, ASTM D445, ASTM D446, ISO 3104, ISO 3105 |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2001-II |
| Compliance Standards | ASTM D86, GB/T 6536, ISO 3405, IP 123 |
| Temperature Range | 0–400 °C (±0.1 °C) |
| Condenser & Receiving Chamber Temp Control | 0–60 °C (±0.1 °C) |
| Volume Measurement Range | 0–100 mL (0.1 mL resolution) |
| Data Storage Capacity | ≥5,000 test records |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 525 × 590 × 585 mm |
| Net Weight | 84 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1022-III |
| Cooling Principle | Single-stage & cascade compressor refrigeration |
| Temperature Control Range | Bath I: −20 °C to 10 °C |
| Bath II | −28 °C to 10 °C |
| Bath III | −35 °C to 10 °C |
| Bath IV (tiltable 45°) | −69 °C to 10 °C |
| Temperature Stability | ±0.5 °C (Baths I–III), ±1.0 °C (Bath IV) |
| Cooling Capacity | Four independent baths, eight sample positions |
| Power Rating | 900 W |
| Input Voltage | 198–242 V AC |
| Frequency | 49–51 Hz |
| Compliance Standards | GB/T 3535, GB/T 510, GB/T 6986, SH/T 0248, ASTM D97, ASTM D2500, ASTM D6371, ISO 3016, ISO 3015, IP 309 |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A5 |
| Measurement | Diesel Cetane Number (CN) |
| Form Factor | Benchtop |
| Standards Compliance | ASTM D613, ISO 5165, IP 41, GB/T 386 |
| Test Range | 0–100 CN (Typical: 30–85 CN) |
| Compression Ratio Adjustment | 8:1 to 36:1 |
| Engine Speed | 900 ± 9 rpm |
| Injection Timing | 13.0° BTDC ± 0.2° |
| Injector Opening Pressure | 10.30 ± 0.34 MPa |
| Fuel Flow Rate | 13.0 ± 0.2 mL/min |
| Cooling Water Capacity | ≥60 L |
| Power Supply | AC 380 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 1520 × 900 × 1760 mm |
| Net Weight | 1200 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SKY1003-IVA |
| Price | Upon Request |
| Test Method Compliance | ASTM D445, ASTM D446, GB/T 265, GB/T 30515, ISO 3104, ISO 3105, IP 71 |
| Temperature Control Range | 20–100 °C (optional cooling unit for sub-ambient control |
| Temperature Stability | ±0.01 °C |
| Timing Resolution | 0.01 s |
| Kinematic Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Sample Volume | 13–15 mL |
| Auto-sampler Capacity | 24 positions |
| Bath Volume | 2 L |
| Bath Fluid | Dimethyl silicone oil |
| Preheating Capability | Central & lateral heating (RT–95 °C) |
| Cleaning System | Dual-solvent programmable wash |
| Drying Method | Filtered dry air purge |
| Safety Features | Low solvent detection, overtemperature cutoff, bath level monitoring |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | ≤1000 W (heater: 600 W) |
| Dimensions (W×D×H) | 580 × 560 × 710 mm |
| Net Weight | 70 kg (including bath fluid) |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1008-V |
| Temperature Control Range | 0 °C to –68 °C |
| Temperature Stability | ±0.5 °C |
| Bath Type | Metal Cooling Bath (No Cryogenic Fluid Required) |
| Sample Positions | 2 |
| Tilt Angle | 45° |
| Tilt-Activated Timer | Auto-starts at 45° tilt |
| Rated Power | 650 W |
| Dimensions (L×W×H) | 620 mm × 440 mm × 460 mm |
| Net Weight | 52 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYP9001-IV |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Compressor Type | Hermetic Scroll Compressor |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±3 °C |
| Refrigeration Capacity | 9 kW |
| Total Electrical Power Input | 3.5 kW |
| Pump Flow Rate | 1.37 m³/h |
| Pump Head | 44 m |
| Reservoir Volume | 60 L |
| Airflow (for auxiliary cooling system) | 2900 m³/h |
| Power Supply | 380–415 V, 50 Hz |
| Safety Protections | High/Low Pressure Switches, Phase Failure & Reverse Phase Protection, Undervoltage Lockout, Overload & Motor Thermal Protection, Freeze Protection |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | SKY5101-I |
| Pricing | Upon Request |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP2008-II |
| Evaporation Bath | 5-position metal bath |
| Temperature Control Range | 160–165 °C (bath), 150–160 °C (test port) |
| Air Pressure | ≤35 kPa |
| Air Flow per Port | 36 L/min ± 3.6 L/min |
| Heating Power | 3300 W |
| Power Supply | 220 VAC ±10%, 50 Hz ±1 Hz |
| Dimensions | 420 × 420 × 400 mm |
| Standards Compliance | GB/T 8019, ISO 6246, ASTM D381 |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP3006-I |
| Standard Compliance | GB/T 12579, ASTM D892 |
| Test Temperatures | 24 °C and 93.5 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Bath Configuration | Dual independent constant-temperature water baths |
| Cylinder Capacity | 1000 mL (dedicated graduated cylinder) |
| Gas Diffuser Diameter | 25.4 mm |
| Diffuser Maximum Pore Size | ≤80 µm |
| Air Permeability at 2.45 kPa | 3000–6000 mL/min |
| Heating Power | 1500 W + 750 W (93.5 °C bath) |
| Cooling System | Integrated refrigeration unit for 24 °C operation at ambient >15 °C |
| Temperature Sensor | Pt100 platinum resistance thermometer |
| Timer Synchronization | Mains-frequency synchronized, ±0.05 s accuracy |
| Power Supply | AC 220 V, 50 Hz, 15 A |
| Dimensions (W×D×H) | 980 mm × 580 mm × 760 mm |
| Diffuser Interface | Removable threaded coupling |
| Control Architecture | Separated electrical and airflow control cabinet |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP4110-I |
| Heating Method | Aluminum Block Furnace (Alloy Cast Aluminum) |
| Heating Power | 700 W or 750 W |
| Sample Capacity | 6 Test Cavities |
| Grease Cup | Chrome-Plated Brass, Compliant with GB/T 3498 |
| Test Tube | Edge-Rimmed Thin-Walled Soft Glass, Compliant with GB/T 3498 |
| Cup Holder | Heat-Resistant Hard Glass |
| Temperature Sensor | Liquid-in-Glass Thermometer per GB/T 514, Range: −5 to 400 °C, Graduation: 1 °C |
| Standards Compliance | GB/T 3498, ASTM D2265 |
| Application | Laboratory-Scale Dropping Point Determination of Lubricating Greases |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP4106-I |
| Motor | Horizontal single-phase capacitor-start motor, 220 V AC, 50 Hz, 370 W, 1400 rpm |
| Shear Rate | 60 cycles/min |
| Stroke | 67–71 mm |
| Orifice Diameter on Plate | Ø6.35 mm (+0.13/−0.00 mm) |
| Temperature Range | 0–50 °C (bimetallic thermometer, 0.5 °C graduation) |
| Max Counter Capacity | 99999 |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 269 |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP3011-II |
| Application Standard Compliance | GB/T 11143, ASTM D665, IP 135 |
| Test Temperature | 60 ± 1 °C |
| Stirring Speed | 1000 ± 50 rpm |
| Stirrer Geometry | Inverted "T"-shaped blade (25 × 6 × 0.6 mm) |
| Test Specimen Rod | Conforms to GB/T 11143 / ASTM D665 / IP 135 specifications |
| Sample Cup | Φ70 × 127 mm, 400 mL tall-form beaker (no spout) |
| Thermometer Range | 50–70 °C, graduation 0.5 °C |
| Bath Capacity | High-volume constant-temperature water bath |
| Parallel Testing Capacity | 4 samples simultaneously |
| Stirring Mechanism | Synchronous belt-driven, vertically adjustable shafts with quick-release clamps |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1017-II |
| Heating Medium | Aluminum Block Metal Bath |
| Temperature Range | 40–200 °C |
| Setpoint Accuracy | ±0.2 °C |
| Inter-hole Temperature Uniformity | ≤1 °C (max gradient across six wells) |
| Heating Power | 800 W |
| Test Capacity | 6 simultaneous tests (3 pressure bombs + 3 cylindrical test tubes) |
| Timer Range | 0–599 min (1-min increments) |
| Max Pressure Rating | 0.7 MPa |
| Compliance | GB/T 5096, ASTM D130, ISO 2160, IP 154 |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2002-II |
| Analysis Method | Reid Method (ASTM D323) |
| Test Range | 0–180 kPa |
| Accuracy | ±0.1 kPa |
| Temperature Control | 37.8 °C ±0.1 °C (PID) |
| Pressure Sensor Range | 0–200 kPa, Accuracy: 0.2% FS |
| Pressure Gauge | 0–160 kPa, Class 0.25 |
| Test Capacity | 3 parallel stainless-steel bomb units |
| Rotation | Horizontal 350° bidirectional automatic oscillation |
| Display | 7-inch color touchscreen |
| Data Storage | Internal database (500 test records) |
| Communication | RS232, RJ-45 (LIMS-compatible) |
| Power | AC 220 V ±10%, 50 ±1 Hz, ≤1600 W total |
| Dimensions (W×D×H) | 880 × 440 × 560 mm |
| Net Weight | 50 kg |
| Safety Features | Low-level water protection, auto-shutdown & alarm, system self-diagnostic |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | SYP4100-I |
| Price | Upon Request |
| Penetration Time Range | 0–9 min 59 s |
| Time Accuracy | ±0.1 s |
| Max Penetration Depth | ≤620 dmm (0.1 mm increments) |
| Standard Cone Mass | 102.5 g (conforms to GB/T 269, ISO 2137, ASTM D217, IP 50) |
| Standard Rod Mass | 47.5 g |
| Digital Depth Measurement System | Yes |
| Manual Release Mechanism | Integrated |
| Horizontal Leveling Adjustment | Precision Knob-Actuated Platform |
| Operating Environment | Ambient or Constant-Temperature Water Bath Compatible |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1003-IXB |
| Temperature Control Range | 20–100 °C (20 °C requires optional immersion chiller) |
| Temperature Stability | ±0.01 °C |
| Bath Capacity | ~18 L |
| Bath Dimensions | Ø300 × 300 mm (hardened borosilicate glass, double-wall construction) |
| Test Stations | 4 independent capillary viscometer ports |
| Timing Resolution | 0.1 s per channel, auto-calculation of kinematic viscosity (ν, mm²/s) |
| Heating Power | 1600 W |
| Stirring Motor | 40 W, 1250 rpm, impeller Ø50 mm |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 580 × 400 × 482 mm |
| Weight | 15 kg |
| Compliance | GB/T 265, ISO 3104, ASTM D445, SH/T 0173 |
| [Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY3012-III |
| Test Method Compliance | ASTM D2272, ASTM D2112, SH/T 0193, IP 229 |
| Temperature Control Accuracy | ±0.1°C at 140.0°C and 150.0°C |
| Sample Mass | 50 g ±0.5 g |
| Oxygen Bomb Rotation Speed | 100 rpm ±1 rpm |
| Oxygen Charging Pressure | 620 kPa ±1.4 kPa (max 680 kPa) |
| Pressure Measurement Range | 0–1.6 MPa, accuracy 0.1% FS |
| Oxygen Bomb Tilt Angle | 30° |
| Heating Medium | Solid metal bath |
| Power Supply | AC 220 V ±10%, 50/60 Hz, 1400 W |
| Dimensions (W×D×H) | 320 × 540 × 640 mm |
| Net Weight | 63 kg |
| Ambient Operating Conditions | 20–30°C, 20–80% RH] |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP2001-VIC |
| Distillation Configuration | Front-mounted dual-bath dual-curved-tube |
| Temperature Range | Ambient to 400 °C |
| Left Bath Temp Control | 0–60 °C, ±0.5 °C accuracy |
| Right Bath Temp Control | 0–60 °C, ±0.5 °C accuracy |
| Condensate Cylinder Bath Temp | 0 °C to ambient, auto-controlled |
| Heating Power | 0–1200 W (continuously adjustable) |
| Supply Voltage | 220 V ±10%, 50 Hz ±1 Hz |
| Total Power Consumption | 2800 W |
| Dimensions (L×H×D) | 664 × 598 × 594 mm |
| Weight | 70 kg |
Show next