- All
- Favorite
- Popular
- Most rated
| Brand | Supmile |
|---|---|
| Origin | Jiangsu, China |
| Model | KQ-AS2000VDE |
| Capacity | 160 L |
| Ultrasonic Frequencies | 45 / 80 / 100 kHz |
| Total Ultrasonic Power | 2000 W |
| Power Adjustment Range | 40–100% |
| Heating Temperature Range | 10–80 °C |
| Timer Range | 1–480 min |
| Sound-Dampening Lid | Yes |
| Water Inlet/Drain Control | Electrically Actuated |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Product Line | ED and EHD Series |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Semi-Automatic |
| Sample Capacity | Up to 77 positions |
| Maximum Sample Mass | ≥5 g per vessel |
| Heating Technology | Surround-Heating Graphite Block with PID-Controlled Temperature Regulation |
| Thermal Uniformity | ≤±1.5 °C across block surface |
| Construction | Fully Corrosion-Resistant Enclosure with High-Temperature Anti-Corrosion Coated Graphite Surface |
| Insulation Material | Imported High-Efficiency Thermal Insulation |
| Energy Efficiency | Optimized thermal retention yielding 2–5× faster digestion vs. conventional hot plates |
| Brand | YDWG |
|---|---|
| Origin | Shanghai, China |
| Model | SGW®X-4A |
| Temperature Range | Ambient to 360 °C |
| Heating Rate | 0.5–20 °C/min |
| Temperature Repeatability | ±1 °C (<200 °C), ±2 °C (≥200 °C) |
| Temperature Accuracy | ±0.5 °C |
| Capillary Dimensions | OD Φ1.4 mm, ID Φ0.9 mm |
| Sample Capacity | 3 samples |
| Temperature Resolution | 0.1 °C |
| Brand | Supmile |
|---|---|
| Origin | Jiangsu, China |
| Model | KQ218 |
| Capacity | 0.6 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 70 W |
| Timer Range | 1–10 min (adjustable) |
| Lid | Sound-dampening cover included |
| Drain/Refill | Manual control |
| Construction | 304 stainless steel tank |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 223 × 114 × 131 mm |
| Tank Internal Dimensions (W×D×H) | 167 × 90 × 52 mm |
| Standard Accessories | Stainless steel mesh basket, sound-dampening lid |
| Brand | Yarong |
|---|---|
| Origin | Shanghai, China |
| Model | YRDC-1010 |
| Instrument Type | Vertical |
| Temperature Stability | ≤±0.05 °C |
| Temperature Uniformity | ≤±0.05 °C |
| Setpoint Resolution | 0.1 °C |
| Operating Range | −10 °C to 100 °C |
| Bath Opening | 180 mm × 140 mm |
| Heating Power | 1000 W |
| Bath Volume | 10 L |
| Vibration Stability | Low-vibration, stable operation |
| External Dimensions | 500 mm × 400 mm × 600 mm |
| Net Weight | 30 kg |
| Compatible Heat Transfer Media | Deionized Water or Thermal Oil |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB2000-C |
| Stirrer Type | Electric Overhead Stirrer |
| Max. Mixing Volume | 50 L (H₂O) |
| Speed Range | 20–2000 rpm |
| Speed Accuracy | ±1 rpm |
| Torque | ≤70 N·cm |
| Max. Viscosity | ≤20,000 cP |
| Motor Power Input/Output | 70 W / 50 W |
| Clamp Diameter | ≤10 mm |
| Reversibility | Yes |
| Control Interface | LCD Digital Display, RS-232 Port, 0–20 mA & 0–10 V Analog Input, 0–5 V Analog Output, Footswitch Port |
| Dimensions (W×D×H) | 105 × 160 × 185 mm |
| Enclosure Finish | Corrosion-Resistant Surface Treatment |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | RG-3618AA |
| Wavelength Range | 190–900 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–2.0 A (Absorbance) |
| Optical System | Dual-Beam |
| Lamp Positions | 8-position rotating turret (compatible with high-performance hollow cathode lamps) |
| Background Correction | Combined deuterium lamp and self-reversal (SR) full-spectrum background correction |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | T3202S |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm (standard), adjustable to 0.5/1/2/4/5 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Display | 10.1-inch capacitive touchscreen |
| Data Storage | Internal 8 GB + USB drive support |
| Interface | RS-232C, USB Device, USB Host |
| Onboard Memory | Up to 5000 absorbance measurements or 500 calibration curves |
| Optional Accessories | 8-position rotating cuvette changer, integrated flow cell system |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T |
| Display | 7-inch high-resolution color touchscreen |
| Data Interface | USB storage, Bluetooth printing & mobile app integration |
| Scan Speed | Up to 3000 nm/min (high mode) |
| Scan Interval Options | 0.1, 0.2, 0.5, 1, 2, 5 nm |
| Kinetic Sampling Interval | 0.5 s minimum |
| Kinetic Duration | Up to 9 hours |
| Calibration Modes | Zero-order, first-order (with/without intercept), second-order, third-order polynomial regression |
| Standard Curve Methods | Single-wavelength, dual-wavelength (isosbestic point), three-point calibration |
| File Capacity | 100 measurement records per test type |
| Compliance | Designed for routine QC and R&D use in GLP-aligned laboratories |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-6536A |
| Test Pressure | Atmospheric (0.1 MPa nominal) |
| Temperature Control Range | (Ambient + 10)°C to 60°C (adjustable in 0.1°C increments) |
| Temperature Accuracy | ±0.5°C |
| Condensate Volume Measurement | 100 mL graduated cylinder (1 mL graduation) |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Dual-Sample Capability | Yes (independent dual-channel operation) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PXSJ-226T |
| Instrument Type | Benchtop |
| Ion Measurement Range | 1.00 × 10⁻⁹ to 9.99 × 10⁹ (selectable units: mol/L, mmol/L, g/L, mg/L, μg/L, ppm) |
| Detection Limit | 1.00 × 10⁻⁹ to 9.99 × 10⁹ (same unit options) |
| Response Time | ≤5 s |
| Accuracy Class | 0.001 |
| Temperature Range | −10.0 to 135.0 °C (14.0 to 275.0 °F) |
| Display | High-resolution color LCD touchscreen |
| Input Protection Rating | IP54 |
| Calibration | 1–6-point calibration for pH/ion electrodes |
| Compliance | GLP-compliant data management |
| Connectivity | RS-232, USB, optional auto-sampler interface |
| Data Storage | 1000 measurement records with timestamp, electrode ID, calibration history, and user log |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SYD-3536D |
| Detection Method | Cleveland Open-Cup (COC) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 400 °C |
| Ignition Method | Active fuel-gas electronic ignition with visible flame |
| Power Supply | AC (220 ± 5%) V, 50 Hz |
| Max. Power Consumption | ≤750 W |
| Temp. Resolution | 0.1 °C |
| Heating Rate | 14–17 °C/min (initial), 5–6 °C/min (final 20 °C before preset flash point) |
| Flame Control | Precision adjustable gas valve |
| Data Transmission | Bluetooth 5.0 |
| Atmospheric Pressure Compensation | Integrated sensor with automatic flash point correction |
| Cloud Data Storage | Encrypted remote sync with audit-ready log history |
| Brand | Supmile |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KQ-700ES |
| Instrument Type | General-Purpose |
| Tank Capacity | 22.5 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 700 W |
| Temperature Control Range | Ambient to 80 °C |
| Timer Adjustment Range | 1–30 min |
| Sound-Dampening Lid | Included |
| Drain/Inlet | Manual Valve Control |
| Heating Power | 1000 W |
| Internal Tank Dimensions | 500 × 300 × 150 mm |
| Overall Dimensions | 530 × 320 × 383 mm |
| Tank Material | 304 Stainless Steel |
| Transducer Configuration | Standard 50 W per element, 40 kHz |
| Power Supply | 220 V / 50 Hz |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-4802 |
| Optical System | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Drift | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphic LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 23 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Laboratory Conductivity Meter |
| Measurement Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Conductivity Range | 0.000 µS/cm to 3000 mS/cm |
| TDS Range | 0.000 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Salinity Range | 0.00–8.00% (w/w) |
| Temperature Range | −5.0 to 130.0 °C |
| Accuracy | ±0.5% of full scale (FS) |
| Minimum Resolution | 0.001 µS/cm |
| Calibration | Up to 5-point conductivity calibration with auto-recognition of GB-standard reference solutions (4 preloaded) |
| Compensation Modes | Automatic temperature compensation (ATC), pure water conductivity correction, seawater salinity compensation |
| Connectivity | RS232/USB interface for PC and USB flash drive |
| Data Management | 1000 stored measurement records per parameter type |
| Software Compatibility | Leici LabSuite™ PC software (optional) for data export, statistical analysis, report generation, and 21 CFR Part 11–compliant electronic signatures |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Lab |
| Instrument Classification | Microchannel Reactor |
| Usable Volume | Small-Scale |
| Instrument Material | Specialty Glass |
| Operating Pressure | Low to Medium Pressure (0–18 bar g) |
| Capacity | 10 mL |
| Flow Rate Range | 0–10 mL/min |
| Operating Temperature Range | −40 °C to 200 °C |
| Reactor Module Internal Volume | 2.7 mL per module |
| Light Sources | 365 nm, 385 nm, 405 nm, 475 nm, 610 nm, and 4000 K white LED |
| LED Irradiance | >100 mW/cm² (adjustable) |
| Cooling | Liquid-cooled LED modules |
| Control Interface | Wireless wavelength & intensity selection |
| Sealing Materials | PFA, PETE, Perfluoroelastomer |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PXBJ-287L |
| Instrument Type | Portable |
| Ion Measurement Range | (−2.000 to 20.000) pX |
| Resolution | 0.001 pX |
| Temperature Range | (−10.0 to 135.0) °C / (14.0 to 275.0) °F |
| IP Rating | IP65 |
| Calibration Points | 1–8 for pH/pX, 1 for ORP |
| Data Storage Capacity | 1,000 datasets per parameter type |
| Connectivity | USB, Bluetooth 4.2, U-disk support, LIMS-compatible via dedicated software |
| Power | Rechargeable Li-ion battery with PC/mobile power bank charging capability |
| Brand | Zelab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Center60 |
| Pure Water Grade | Type I (ASTM D1193-20) |
| Resistivity | >10 MΩ·cm at 25°C |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Production Capacity | 60 L/h (DI water) |
| RO Recovery Rate | ≥95% |
| Input Water Requirement | TDS <200 ppm, 5–45°C, 1.0–4.0 kgf/cm² |
| Power Supply | AC 220 V ±10%, 50 Hz, 240 W |
| Dimensions (L×W×H) | 57×60×150 cm |
| Weight | ~70 kg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L6 |
| Optical Design | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.03% at 220 nm (NaI) |
| Automation Level | Automatic Wavelength Scanning & Lamp Switching |
| Connectivity | USB 2.0, Wi-Fi Module, Bluetooth 4.2 |
| Data Storage Capacity | 500 spectra, 30 calibration curves |
| Software Compatibility | Yokelab PC Suite (optional), Excel-compatible CSV export |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | Halo Sense |
| Monitoring Parameters | VOCs, Acid Gases, Formaldehyde |
| Environmental Operating Range | Temperature 10–30 °C, Relative Humidity 30–80 % RH |
| Power Consumption | 10 W |
| Electrical Supply | 100–240 V AC, 50–60 Hz |
| Sensor Technology | Semiconductor & Electrochemical Sensors (gas-specific) |
| Mounting Options | Benchtop or Wall-Mounted |
| Status Indication | Smart RGB Light Band |
| Data Acquisition | eGuard Software (PC & Mobile) |
| Compliance Context | Designed for GLP-aligned lab environments |
| Brand | BRAND® |
|---|---|
| Origin | Germany |
| Model | 4760251 |
| Capacity | 25 mL |
| Accuracy (A) | ≤ ±0.07% / ≤ ±18 µL |
| Coefficient of Variation (CV) | ≤ 0.025% / ≤ 6 µL |
| Compliance | DIN EN ISO 385 |
| Interface | RS232 (optional) |
| Power | Battery-operated (no external power required) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 191-T2 HACCP |
| Measurement Range | −50 to +140 °C |
| Accuracy | ±0.2 °C (−50 to −40 °C), ±0.1 °C (−40 to +140 °C) |
| Resolution | 0.01 °C |
| Probe Length | 115 mm |
| Probe Diameter | 3 mm |
| Housing Diameter × Height | 20 × 59 mm |
| IP Rating | IP68 |
| Sensor Type | Pt1000 |
| Response Time t₉₀ | 6 s |
| Memory Capacity | 60,000 readings |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (10 s interval at +121 °C) |
| Operating Temperature | −50 to +140 °C |
| Storage Temperature | −20 to +50 °C |
| Measurement Interval | 1 s to 24 h |
| Certifications | CE |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | VF205B |
| Vacuum Level | ≥150 mbar |
| Air Flow Rate | ≤34 L/min |
| Motor Speed | 1450 rpm |
| Interface Diameter | 9 mm |
| Weight | 7.5 kg |
| Noise Level | 50 dB(A) |
| Power Supply | 220–240 V / 50 Hz |
| Rated Power | 80 W |
| Includes | VF2 Glass Filtration Bottle Set |
| Brand | Yarong |
|---|---|
| Origin | Shanghai, China |
| Model | RE-52CS-1 |
| Temperature Range | Ambient to 99 °C (±1 °C) |
| Rotation Speed | 0–120 rpm (electronic stepless control) |
| Condenser Type | Vertical double-layer glass condenser |
| Feed Tube | Valve-type adjustable addition tube |
| Lift Mechanism | Lever-type vertical lift, max travel 150 mm |
| Water Bath Pan | 26 × 15 cm stainless steel with PTFE-coated interior |
| Power Rating | 1.0 kW |
| Supply Voltage | 220 V AC / 50 Hz |
Show next